Sony KDL-40X4000 / KDL-46X4000 / KDL-52X4000 (serv.man2) Service Manual ▷ View online
KDL-40/46/52X4000 (WB) 2-5
NO
2 times
YES
See
1) Power Error
RED LED Blinks
NO
9 times
YES
See
6) FAN Error
NO
5 times
YES
See
2) T-CON Error
NO
6 times
YES
See
3) BACK LIGHT Error
NO
7 times
YES
See
4) TEMP Error
NO
8 times
YES
See
5) AUDIO Error
13 times
YES
See
7) Balancer Error
2-5-2. RED LED BLINKS (Chart C)
KDL-40/46/52X4000 (WB) 2-6
1) Power Error (R ED 2 tim es blink )
This indicates POWER Error, Low B error of 12V from G6 board. TV Micro (on ACW-TW board)
monitors pin79 and pin138 to detect POWER_ERR and shuts down chassis power to
Standby status.
monitors pin79 and pin138 to detect POWER_ERR and shuts down chassis power to
Standby status.
TV Micro pin138 Normal condition : Low / Error case : High
TV Micro pin79 i_lb_err< 0.7V(PW_ERR_LEV)
TV Micro pin79 i_lb_err< 0.7V(PW_ERR_LEV)
- Check 12V at CN 1000 on ACW-TW board. And F1001 on ACW-TW board has 12V or not.
- Check G6 board.
- Check G6 board.
2) T-CON Error (R ED 5 tim es blink )
This indicates T-CON RDY signal error from timing controller of Panel module.
BE micro pin128 on FBA board detects it.
BE micro pin128 on FBA board detects it.
BE Micro pin128 Normal condition : High / Error case : Low
Replace Panel module.
3) B ack Light Error (R ED 6 tim es blink )
This indicates panel power circuit error such as inverter.
BE micro pin 78 on FBA board detects it.
BE micro pin 78 on FBA board detects it.
BE Micro pin 78 Normal condition : High / Error case : Low
Replace D4 board in case of CCFL model.
KDL-40/46/52X4000 (WB) 2-7
4) Tem p Error (R ED 7 tim es blink )
This indicates high temperature inside chassis. IC1000 on ACW-TW board Side is monitoring
temperature. IC1000 is controlled by BEM I2C.
temperature. IC1000 is controlled by BEM I2C.
When it happens;
- Check chassis environment.
- Check around IC1000 and replace ACW-TW board if temperature monitoring circuit has problem.
- Check chassis environment.
- Check around IC1000 and replace ACW-TW board if temperature monitoring circuit has problem.
5) Audio Error (R ED 8 tim es blink )
This indicates Audio Error. (Protection)
It happens;
- Error of Speakers and Harness.
- Error of Speakers and Harness.
Check Voltage at CN1002 20pin on ACW-TW board. ( Low = Normal , High= Error)
- Low Voltage at IC1800 [ Audio_Vcc(=12V) , A9V , D3.3V ]
- Error of IC1800
- Error of IC1800
Replace ACW-TW board.
6) FAN Error (R ED 9 tim es blink )
This indicates FAN error. (except 40 inch model)
BE micro pin154 on FBA board detects it.
BE micro pin154 on FBA board detects it.
BE Micro pin154 Normal condition : Low / Error case : High
- Check the harnessconnection of FAN.
- Check the Voltage at CN1301 on ACW-TW board. ( Low = Error , High = Normal)
- Check the Voltage at CN1301 on ACW-TW board. ( Low = Error , High = Normal)
Replace the FAN.
KDL-40/46/52X4000 (WB) 2-8
7) B alancer Error (R ED 13 tim es blink )
This indicates Inverter board error of panel module.
BE micro pin163 on FBA board detects it.
BE micro pin163 on FBA board detects it.
BE Micro pin163 Normal condition : High / Error case : Low