SAFETY CHECK-OUT
After correcting the original service problem, perform the following
safety checks before releasing the set to the customer:
1.  Check the area of your repair for unsoldered or poorly soldered
connections. Check the entire board surface for solder splashes and
bridges.
2. Check the interboard wiring to ensure that no wires are “pinched” or
touching high-wattage resistors.
3. Check that all control knobs, shields, covers, ground straps, and
mounting hardware have been replaced. Be absolutely certain that
you have replaced all the insulators.
4. Look for unauthorized replacement parts, particularly transistors,
that were installed during a previous repair. Point them out to the
customer and recommend their replacement.
5. Look for parts which, though functioning, show obvious signs of
deterioration. Point them out to the customer and recommend their
replacement.
6.  Check the line cords for cracks and abrasion. Recommend the
replacement of any such line cord to the customer.
7.  Check the antenna terminals, metal trim, “metallized” knobs, screws,
and all other exposed metal parts for AC leakage. Check leakage as
described below.
Leakage Test
The AC leakage from any exposed metal part to earth ground and
from all exposed metal parts to any exposed metal part having a
return to chassis, must not exceed 0.5 mA (500 microamperes).
Leakage current can be measured by any one of three methods.
1. A commercial leakage tester, such as the Simpson 229 or RCA
WT-540A. Follow the manufacturers’ instructions to use these
instructions.
2. A battery-operated AC milliampmeter. The Data Precision 245
digital multimeter is suitable for this job.
3. Measuring the voltage drop across a resistor by means of a VOM
or battery-operated AC voltmeter. The “limit” indication is 0.75
V, so analog meters must have an accurate low voltage scale.
The Simpson’s 250 and Sanwa SH-63TRD are examples of
passive VOMs that are suitable. Nearly all battery-operated digital
multimeters that have a 2 VAC range are suitable (see Figure A).
How to Find a Good Earth Ground
A cold-water pipe is a guaranteed earth ground; the cover-plate
retaining screw on most AC outlet boxes is also at earth ground. If the
retaining screw is to be used as your earth ground, verify that it is at
ground by measuring the resistance between it and a cold-water pipe
with an ohmmeter. The reading should be zero ohms.
If a cold-water pipe is not accessible, connect a 60- to 100-watt
trouble- light (not a neon lamp) between the hot side of the receptacle
and the retaining screw. Try both slots, if necessary, to locate the hot
side on the line; the lamp should light at normal brilliance if the screw
is at ground potential (see Figure B).
T
o Exposed Metal
Parts on Set
0.15 µF
Earth Ground
AC
V
oltmeter
(0.75V)
Trouble Light
AC Outlet Box
Ohmmeter
Cold-water Pipe
Figure A. Using an AC voltmeter to check AC leakage.
Figure B. Checking for earth ground.
7
KDL-40X200A/46X200A
KDL-40X200A/46X200A 
SELF-DIAGNOSTIC FUNCTION
Self Diagnosis
Supported model
Control Buttons
Description of LED Indictors
8
KDL-40X200A/46X200A
KDL-40X200A/46X200A 
The units in this manual contain a self-diagnostic function. If an error occurs, the POWER LED will automatically begin to flash. The number of times 
the LED flashes translates to a probable source of the problem. A definition of the POWER LED flash indicators is listed in the instruction manual for 
the user’s knowledge and reference. If an error symptom is difficult to reproduced use the Remote Commander to display the record that is stored at 
the internal NVM to specify the cause of the failure.
Diagnostic Test Indicators
When an error occurs, the POWER LED will flash a set number of times to indicate the possible cause of the problem. If there is more than one error, 
the LED will identify the first of the problem areas. If the errors occur simultaneously, the one that corresponds to the fewest flashes is identified first.
Results for all of the following diagnostic items are displayed on screen. No error has occurred if the screen displays a “0”.
1.  TV must be in standby mode. (Power off).
2.  Press the following buttons on the Remote Commander within a second of each other:
The Self Check list displays.
This differs from accessing Service Adjustments.





























 


 


 


 



KDL-40X200A/46X200A
KDL-40X200A/46X200A 
SECTION 1:  DISASSEMBLY
1-1. 
REAR CABINET REMOvAL
 
Rear Cabinet Assembly
Two screws 
(+PSW M5X12) 
Two screws 
(+BVST 4X12) 
One screw 
(+BVST 4X8) 
One screw 
(+BVTP 3X12) 
Fourteen screws 
(+BVTP2 4X16)
Page of 127