DOWNLOAD Sony KDL-26NL140 / KDL-32NL140 / KDL-37NL140 Service Manual ↓ Size: 29.24 MB | Pages: 102 in PDF or view online for FREE

Model
KDL-26NL140 KDL-32NL140 KDL-37NL140
Pages
102
Size
29.24 MB
Type
PDF
Document
Service Manual
Brand
Device
TV
File
kdl-26nl140-kdl-32nl140-kdl-37nl140.pdf
Date

Sony KDL-26NL140 / KDL-32NL140 / KDL-37NL140 Service Manual ▷ View online

49
KDL-26NL140/32NL140/37NL140
KDL-26NL140/32NL140/37NL140
KDL-37NL140 ONLY
RF CABLE (CONTINUED)
MA2 Wire Dressing 37NL [Rev: 1.0]
HM3 cable through this 
clamp 
RF cable through
this clamp 
Spkr cable: 
1-910-044-84
Spkr + HM3 cables 
through this clamp 
Page 10/11 
MB609204 (11 / 23)
MB609204 (11 / 23)
MB609204 (11 / 23)
MB609204 (11 / 23)
MB609204 (11 / 23)
MB609204 (11 / 23)
MB609204 (11 / 23)
MB609204 (11 / 23)
MB609204 (11 / 23)
MB609204 (11 / 23)
50
KDL-26NL140/32NL140/37NL140
KDL-26NL140/32NL140/37NL140
KDL-37NL140 ONLY
MA2 Wire Dressing 37NL [Rev: 1.0]
AC Cord: 
50 mm 
G2
AC HOLDER 
4-022-115-12
AC cord through this clamp 
(before the ferrite) 
Page 11/11 
MB609204 (12 / 23)
MB609204 (12 / 23)
MB609204 (12 / 23)
MB609204 (12 / 23)
MB609204 (12 / 23)
MB609204 (12 / 23)
MB609204 (12 / 23)
MB609204 (12 / 23)
MB609204 (12 / 23)
MB609204 (12 / 23)
MB609204 (12 / 23)
AC CORD
51
KDL-26NL140/32NL140/37NL140
KDL-26NL140/32NL140/37NL140
2-1.  RESETTING THE TV TO THE FACTORY DEFAULTS
Traditional Service Mode is not available in this chassis. The only option for service technicians is to reset all of the settings to the Factory Default from 
the Self Diagnostic screen.
CAUTION: Resetting the TV to the Factory Defaults will over-write all customer settings. Before performing this reset, contact the customer to 
determine what adjustments they have made. 
1.  TV must be in standby mode. (Power off).
2.  Press the following buttons on the Remote Commander within a second of each other: 
 
DISPLAY   
Channel 
5   
Volume 
+  
  TV POWER .
 
The Self Check list displays. 
          
  This is the SAME as accessing Self Diagnostic Function.
Results for all of the following diagnostic items are displayed at the bottom of the screen.  No error has occurred if the screen displays a “0”.
QR0.5-C510
Model Information: 32NL140  8000001
ADC Auto Calibration
Power On Time: 00001H
SMPTE
ColorBar100
ITU 709
Gain
424
1020
420
1020
456
16
8
1840
128
1592
128
1608
424
1020
422
1020
460
16
Offset
Cr
Y
Cb
ITU 601
VGA
2:MAIN POWER  0                       6:BL              0
3:DC ALERT1        0                       7:TEMP       1
4:DC ALERT2        0                       8:Audio      0
5:DC ALERT3        0
Gain
Offset
Gain
Offset
Factory Default
Indicates an error was detected
Indicates no error was detected
Model Information & Serial Number
Software Version
Power Time
Resets all settings
to the Factory Defaults
Diagnostic
List
Stored Data
from ADC calibration
(from factory)
3.  From the Self Diagnostic screen, select Factory Default button and then select Yes.
4.  To start Auto Program, select Yes.
 
NOTE: Allow 30+ minutes for Auto Program to complete.
5.  Using the customers information, reset their adjustments.
SECTION 2:  SERVICE ADJUSTMENTS
52
KDL-26NL140/32NL140/37NL140
KDL-26NL140/32NL140/37NL140
SECTION 3:  DIAGRAMS
3-1. CIRCUIT BOARDS LOCATION
3-2. PRINTED WIRING BOARDS AND 
SCHEMATIC DIAGRAMS INFORMATION
All capacitors are in μF unless otherwise noted. pF : μμF 50WV or 
less are not indicated except for electrolytics and tantalums.
All electrolytics are in 50V unless otherwise specifi ed.
All resistors are in ohms.  k
Ω=1000Ω, MΩ=1000kΩ
Indication of resistance, which does not have one for rating 
electrical power, is as follows: 
Pitch : 5mm 
 
 
    Rating 
electrical 
power 
1
/
 4 
W
1
/
 4 
W in resistance, 
1
/
10 
W and 
1
/
16 
W in chip resistance.
: nonfl ammable resistor
 : fusible resistor
 : internal component
 : panel designation and adjustment for repair
 : earth ground
 : earth-chassis
All variable and adjustable resistors have characteristic curve B, 
unless otherwise noted.
Readings are taken with a color-bar signal input.
Readings are taken with a 10M
Ω digital multimeter.
Voltages are DC with respect to ground unless otherwise noted.
Voltage variations may be noted due to normal production 
tolerances.
All voltages are in V.
S : Measurement impossibility.
: B+line.
: B-line.  (Actual measured value may be different).
: signal path. (RF)
Circled numbers are waveform references.
The components identifi ed by shading and 
!
 symbol are critical for safety. Replace 
only with part number specifi ed. 
The symbol 
 indicates a fast operating fuse and is displayed on the component 
side of the board. Replace only with fuse of the same rating as marked.
Les composants identifi es per un trame et une marque 
!
 sont critiques pour la 
securite.  Ne les remplacer que par une piece portant le numero specifi e.
Le symbole 
 indique une fusible a action rapide. Doit etre remplace par une 
fusible de meme yaleur, comme maque.
NOTE: The components identifi ed by a red outline and a   mark contain confi dential 
information. Specifi c instructions must be adhered to whenever these components 
are repaired and/or replaced. 
See Appendix A: Encryption Key Components in the back of this manual. 
H1 (SWITCH UNIT)
POWER UNIT
G1D (KDL-26NL140/32NL140)
G2D (KDL-37NL140)
HM3
BM
Page of 102
Display