DOWNLOAD Sony KDL-23S2010 / KDL-26S2010 / KDL-32S2010 / KDL-40S2010 / KDL-46S2010 Service Manual ↓ Size: 15.49 MB | Pages: 84 in PDF or view online for FREE

Model
KDL-23S2010 KDL-26S2010 KDL-32S2010 KDL-40S2010 KDL-46S2010
Pages
84
Size
15.49 MB
Type
PDF
Document
Service Manual
Brand
Device
TV
File
kdl-23s2010-kdl-26s2010-kdl-32s2010-kdl-40s2010-kd.pdf
Date

Sony KDL-23S2010 / KDL-26S2010 / KDL-32S2010 / KDL-40S2010 / KDL-46S2010 Service Manual ▷ View online

5
KDL-23S2010/26S2010/32S2010/40S2010/46S2010
KDL-23S2010/26S2010/32S2010/40S2010/46S2010
Television system
American TV Standard
Channel coverage
VHF: 2-13/UHF: 14-69/ Cable TV: 1-125
Antenna
75-ohm external terminal for VHF/UHF
Panel System
LCD (Liquid Crystal Display) Panel
Display Resolution (horizontal x vertical):
1,366 dots x 768 lines
Screen Size (measured diagonally)
26 inches (KDL-26S2010 Only)
32 inches (KDL-32S2010 Only)
40 inches (KDL-40S2010 Only)
Supplied Accessories
Remote Commander RM-YD005
Two Size AA (R6) Batteries
75-ohm coaxial cable
AC Power Cord
HD15-HD15 Cable
Suport Belt, Securing Screw, and Wood Screw
Cable Holder
Operating Instructions
Quick Setup Guide
Warranty Card
Optional Accessories
Headphones Plug Adaptor
Connecting Cables
Wall-Mount Bracket
 SU-WL31 
(KDL-23S2010//26S2010/32S2010 
Only)
  SU-WL51  (KDL-40S2010/46S2010  Only)
!
!
 
"
!
#
$%
!
#
$%
&
&
!
!
"
!
#
$%
!
#
$%
6
KDL-23S2010/26S2010/32S2010/40S2010/46S2010
KDL-23S2010/26S2010/32S2010/40S2010/46S2010
WARNINGS AND CAUTIONS
CAUTION
These servicing instructions are for use by qualifi ed service personnel only. To reduce the risk of electric shock, do not perform any 
servicing other than that contained in the operating instructions unless you are qualifi ed to do so.
WARNING!!
An isolation transformer should be used during any service to avoid possible shock hazard, because of live chassis. The chassis of 
this receiver is directly connected to the ac power line.
!
 SAFETY-RELATED COMPONENT WARNING!!
Components identifi ed by shading and 
!
 mark on the schematic diagrams, exploded views, and in the parts list are critical for 
safe operation. Replace these components with Sony parts whose part numbers appear as shown in this manual or in supplements 
published by Sony. Circuit adjustments that are critical for safe operation are identifi ed in this manual. Follow these procedures 
whenever critical components are replaced or improper operation is suspected. 
ATTENTION!!
Ces instructions de service sont à l’usage du personnel de service qualifi é seulement. Pour prévenir le risque de choc électrique, ne 
pas faire l’entretien autre que celui contenu dans le Mode d’emploi à moins que vous soyez qualifi é faire ainsi.
Afi n d’eviter tout risque d’electrocution provenant d’un chássis sous tension, un transformateur d’isolement doit etre utilisé lors de tout 
dépannage. Le chássis de ce récepteur est directement raccordé à l’alimentation du secteur.
!
 ATTENTION AUX COMPOSANTS RELATIFS A LA SECURITE!!
Les composants identifi es par une trame et par une marque 
!
 sur les schemas de principe, les vues explosees et les listes de 
pieces sont d’une importance critique pour la securite du fonctionnement. Ne les remplacer que par des composants Sony dont 
le numero de piece est indique dans le present manuel ou dans des supplements publies par Sony. Les reglages de circuit dont 
l’importance est critique pour la securite du fonctionnement sont identifi es dans le present manuel. Suivre ces procedures lors de 
chaque remplacement de composants critiques, ou lorsqu’un mauvais fonctionnement suspecte.
7
KDL-23S2010/26S2010/32S2010/40S2010/46S2010
KDL-23S2010/26S2010/32S2010/40S2010/46S2010
SAFETY-RELATED COMPONENT WARNING
There are critical components used in LCD color TVs that are important for safety. These components are identifi ed with shading and 
!
 
mark on the schematic diagrams and the electrical parts list. It is essential that these critical parts be replaced only with the part number 
specifi ed in the electrical parts list to prevent electric shock, fi re, or other hazard. 
NOTE: Do not modify the original design without obtaining written permission from the manufacturer or you will void the original parts and 
            labor guarantee. 
USE CAUTION WHEN HANDLING THE LCD PANEL
When repairing the LCD panel, be sure you are grounded by using a wrist band.
When installing the LCD panel on a wall, the LCD panel must be secured using the 4 mounting holes on the rear cover. 
To avoid damaging the LCD panel:
 do not press on the panel or frame edge to avoid the risk of electric shock.
  do not scratch or press on the panel with any sharp objects.
  do not leave the module in high temperatures or in areas of high humidity for an extended period of time.
  do not expose the LCD panel to direct sunlight.
  avoid contact with water. It may cause a short circuit within the module. 
  disconnect the AC adapter when replacing the backlight (CCFL) or inverter circuit. 
(High voltage occurs at the inverter circuit at 650Vrms.) 
  always clean the LCD panel with a soft cloth material.
  use care when handling the wires or connectors of the inverter circuit. Damaging the wires may cause a short. 
  protect the panel from ESD to avoid damaging the electronic circuit (C-MOS). 
LEAKAGE CURRENT HOT CHECK CIRCUIT
8
KDL-23S2010/26S2010/32S2010/40S2010/46S2010
KDL-23S2010/26S2010/32S2010/40S2010/46S2010
The circuit boards used in these models have been processed using
Lead Free Solder. The boards are identified by the LF logo located
close to the board designation e.g. H1 etc [ see example ]. The
servicing of these boards requires special precautions to be taken as
outlined below.
example 1
It is strongly recommended to use Lead Free Solder material in order to guarantee optimal quality of new solder joints. 
Lead Free Solder is available under the following part numbers :
Due to the higher melting point of Lead Free Solder the soldering iron tip temperature needs to be set to 370 degrees centigrade. 
This requires soldering equipment capable of accurate temperature control coupled with a good heat recovery characteristics.
For more information on the use of Lead Free Solder, please refer to  http://www.sony-training.com
r
e
b
m
u
n
t
r
a
P
r
e
t
e
m
a
i
D
s
k
r
a
m
e
R
9
1
-
5
0
0
-
0
4
6
-
7
m
m
3
.
0
g
K
5
2
.
0
0
2
-
5
0
0
-
0
4
6
-
7
m
m
4
.
0
g
K
0
5
.
0
1
2
-
5
0
0
-
0
4
6
-
7
m
m
5
.
0
g
K
0
5
.
0
2
2
-
5
0
0
-
0
4
6
-
7
m
m
6
.
0
g
K
5
2
.
0
3
2
-
5
0
0
-
0
4
6
-
7
m
m
8
.
0
g
K
0
0
.
1
4
2
-
5
0
0
-
0
4
6
-
7
m
m
0
.
1
g
K
0
0
.
1
5
2
-
5
0
0
-
0
4
6
-
7
m
m
2
.
1
g
K
0
0
.
1
6
2
-
5
0
0
-
0
4
6
-
7
m
m
6
.
1
g
K
0
0
.
1
Page of 84
Display

Click on the first or last page to see other KDL-23S2010 / KDL-26S2010 / KDL-32S2010 / KDL-40S2010 / KDL-46S2010 service manuals if exist.