7
Detected Symptoms
SELF-DIAGNOSTIC FUNCTION
*If a +B overcurrent is detected, stoppage of the vertical defl ection is detected simultaneously.  The symptom that is diagnosed fi rst by the mircrocontroller 
is displayed on the screen.
**Refer to Screen (G2) Adjustments in Section 2-4. of this manual.
Display of Standby/Timer LED Flash Count
2 times
4 times
5 times
LED ON 0.3 sec.
LED OFF 0.3 sec.
LED OFF
3 sec.
 
Standby/Timer LED
 
Diagnostic Item 
 
Flash Count*
 
+B Overcurrent 
 
2 times
 I-Prot 
  4 
times
 IK 
(AKB) 
  5 
times
 
*One fl ash count is not used for self-diagnostic.
Stopping the Standby/Timer LED Flash
Turn off the power switch on the TV main unit or unplug the power cord from the outlet to stop the STANDBY/TIMER LAMP from fl ashing.
Self Diagnosis
Supported model
The units in this manual contain a self-diagnostic function. If an error occurs, the STANDBY/TIMER LED will automatically begin to fl ash. The number of 
times the LED fl ashes translates to a probable source of the problem. A defi nition of the STANDBY/TIMER LED fl ash indicators is listed in the instruction 
manual for the user’s knowledge and reference. If an error symptom cannot be reproduced, the Remote Commander can be used to review the failure 
occurrence data stored in memory to reveal past problems and how often these problems occur.
Diagnostic Test Indicators
When an error occurs, the STANDBY/TIMER LED will fl ash a set number of times to indicate the possible cause of the problem. If there is more than one 
error, the LED will identify the fi rst of the problem areas.
Results for all of the following diagnostic items are displayed on screen.  No error has occurred if the screen displays a “0”.
Power does not turn on 
+B overcurrent (OCP)* 
I-Prot
IK (AKB)
Does not light
2 times
4 times
5 times
2:0 or 2:1
4:0 or 4:1
5:0 or 5:1
•  Power cord is not plugged in.
•  Fuse is burned out (F601). (A Board)
•  H.OUT (Q502) is shorted. (A Board)
•  IC702 is shorted. (C Board)
•  +13V is not supplied. (A Board)
•  IC561 is faulty. (A Board)
•  IC001 is faulty.  (MD Board)
•  Screen (G2) is improperly adjusted.**
No. of times 
STANDBY/  TIMER 
lamp fl ashes
 Diagnostic Item Descrip-
tion
Self-Diagnositc 
Display/ Diagnos-
tic Result
Probable Cause Location
•  Power does not come on.
•  No power is supplied to the TV.
•  AC Power supply is faulty.
•  Power does not come on.
•  Load on power line is shorted.
•  Has entered standby state after horizontal raster.
•  Vertical defl ection pulse is stopped.
•  Power line is shorted or power supply is stopped.
•  No raster is generated.
•  CRT Cathode current detection reference pulse       
output is small.
KD-27FS130
KD-27FS130 
8
Self-Diagnostic Screen Display
For errors with symptoms such as “power sometimes shuts off” or “screen sometimes goes out” that cannot be confi rmed, it is possible to bring up past 
occurrences of failure on the screen for confi rmation.
To Bring Up Screen Test
In standby mode, press buttons on the Remote Commander sequentially, in rapid succession, as shown below:
DISPLAY
  
 Channel  5      
 Sound Volume  -  
 
 POWER
 
Self-Diagnostic Screen Display
 
SELF DIAGNOSTIC
2: +B 
OCP  0
3: +B 
OVP  N/A
4: VSTOP  0 
Numeral “0” means that no fault was detected.
5: AKB 
Numeral “1” means a fault was detected one time only.
101:   WDT 
N/A
Handling of Self-Diagnostic Screen Display
Since the diagnostic results displayed on the screen are not automatically cleared, always check the self-diagnostic screen during repairs. When you 
have completed the repairs, clear the result display to “0”.
Unless the result display is cleared to “0”, the self-diagnostic function will not be able to detect subsequent faults after completion of the repairs.
Clearing the Result Display
To clear the result display to “0”, press buttons on the Remote Commander sequentially when the diagnostic screen is displayed, as shown below:
Channel  8  
  ENTER
Quitting the Self-Diagnostic Screen
To quit the entire self-diagnostic screen, turn off the power switch on the Remote Commander or the main unit.
Self-Diagnostic Circuit
MD BOARD
IC001
Y/CHROMA JUNGLE
A BOARD
IC561
V. OUT
MD BOARD
IC001
SYSTEM
MD BOARD
IC002
MEMORY
IK-AKBIN
FROM
C BOARD
IC702 PIN 5
I-HLDWN
FROM
A BOARD
IC501
PIN 1
72
O-LED
REF
I-Prot
IO-BDAT
BDA
DISPLAY
51
3
78
79
53
5
+B overcurrent (OCP) 
Occurs when an overcurrent on the +B (135V) line is detected by pin 72 of IC001 (MD Board). If the voltage of pin 72 of IC001 (MD Board) is less than 
1V when V.SYNC is more than seven verticals in a period, the unit will automatically turn off. 
I-Prot 
Occurs when an absence of the vertical defl ection pulse is detected by pin 78 of IC001 (MD Board). Power supply will shut down when waveform interval 
exceeds 2 seconds. 
IK (AKB) 
If the RGB levels* do not balance within 2 seconds after the power is turned on, this error will be detected by IC001 (MD Board). TV will stay on, but 
there will be no picture.
*(Refers to the RGB levels of the AKB detection Ref pulse that detects IK).
Note that this differs from entering the Service Mode (Sound Volume  +  ).
KD-27FS130
KD-27FS130 
9
1-1.  REAR COVER REMOVAL
SECTION 1:  DISASSEMBLY
1-2. CHASSIS ASSEMBLY REMOVAL
1  Remove screws from top of cover.
       4 Screws SCREW +BVTP 3X12 TYPE2 TT (B)
2  Remove screws from sides of cover.
       4 Screws SCREW +BVTP 3X12 TYPE2 TT (B)-2 each side
3  Remove screws from sides of cover.
       4 SCREW +BVTP 4X16 TYPE2 TT (B) - 2 each side
4  Remove rear cover
C Board
V Board
Chassis Assembly
3
4
2
1
1  Press on catch tab to release the chassis.
2  Gently pull the chassis forward.
1
2
KD-27FS130
KD-27FS130 
10
1-3. SERVICE POSITION
1  Disconnect the CN501 cable from the A Board.
2  Press on catch tab to release A Board.
3  Gently pull the A Board forward to access the GS and HS Boards.
4  Gently continuing pulling the A Board, GS Board and HS Board forward to
       place in service position.
5  Reconnect CN501.
A Board
GS Board
HS Board
Page of 74