2-5
VPL-VW10HT
2-8. TH, U, BM and V Boards Removal
• Remove the B and Q Boards (Refer to 2-6.).
• Remove the optical unit assy (Refer to 2-7.).
2-9. Power Block Removal
• Remove the optical unit assy (Refer to 2-7.).
5
 Four screws (
+
B3 
x
 6)
6
 BM board
1
 Screw (
+
B3 
x
 6)
7
 Screw (
+
B3 
x
 6)
2
 TH board
8
 Holder (V)
9
 V board
3
 Screw (
+
B3 
x
 6)
4
 U board
1
 Four screws (
+
B3 
x
 6)
3
 Three screws (
+
B3 
x
 6)
2
 Duct
Holder (LPS)
Fin (VW)
4
 Power block
Connector (3P)
2-6
VPL-VW10HT
2-10. Lens Assy Removal
• Remove the C Board (Refer to 2-5.).
2-11. Prism Block Removal
• Remove the B and Q Boards (Refer to 2-6.).
• Remove the optical unit assy (Refer to 2-7.).
5
 Four screws (
+
PSW4 
x
 8)
4
 Lens bracket
      Remove the lens assembly attached 
      to the lens bracket instead of the single 
      lens assembly, if possible.
3
 Four screws (
+
B3 
x
 8)
6
 Lens assy
2
 Lens holder
1
 Two screws (
+
B3 
x
 8)
3
 Two screws (
+
B3 
x
 8)
1
 Four screws (
+
B3 
x
 8)
2
 Lens bracket
8
 Five screws
5
 Polarizer, R-OUT plate
6
 Polarizer, G-OUT plate
7
 Polarizer, B-OUT plate
4
 Prism block
     NOTE: Use extreme care not to tuch the 
                 glass section of prism, LCD and 
                 conductive section of the flexible 
                 cable in particular.
!'
 Polarizer, B-IN plate
!]
 Polarizer, G-IN plate
!-
 Polarizer, B-IN 
     plate
!/
 Washer
9
 Screw
![
 Washer
!=
 Screw
!\
 Screw
!;
 Washer
2-7
VPL-VW10HT
2-12. Note on Lamp Breakage
Note 1
Ehen the lamp broken, its broken pieces may remain inside the unit.
Take off all the pices with gloves using care about a hand cut, before replacing.
Then, the fly-eye lens may be cloudy at the lamp breakage, at that time wipe the suface of the lens with an
authorized lens cleaner kit.
. Cleaner (4-075-337-01)
. Wiper (4-075-338-01)
Note 2
Under the consideration of lamp’s reliability, set the lamp mode to “LOW” during repairing the unit with
the cabinet opening and the lamp on.
3-1
VPL-VW10HT
Section 3
Electrical Adjustments
3-1. Preparations
3-1-1. Equipment Required
.
Oscilloscope
Tektronix 2465 or equivalent
(Bandwidth: 350 MHz or more)
.
NTSC, PAL, SECAM component signal generator
Tektronix TG2000 + AVG1 (Optional module) +
AWVG1 (Optional module) or equivalent
.
VG (Programmable video signal generator)
VG814 or equivalent
.
Digital voltmeter
Advantest TR6845 or equivalent
.
Luminance meter
Note: Perform the following adjustment at least five
minutes after turning on the power.
3-1-2. Setting the Factory Mode
1.
Make sure that the STATUS in the menu is ON.
2.
Exit the menu.
3
Press the keys in the following ORDER:
“ENTER” 
 “ENTER” 
 “LEFT” 
 “ENTER”
4.
The message “Do you wish to enter into the FACTORY
MODE?” will be displayed.
5.
Select YES.
3-2. RGB VCOM Adjustment
1.
Enter the P.DRV of the Device adjust with Factory mode.
2.
Enter the item of 01 VCOM G, and check the 1 line ON/
OFF signal.
3.
Adjust the  
 and 
 keys to minimize the flicker.
Similarly, and perform Red and Blue adjustment
similarly.
(02 VCOM R, 03 VCOM B)
4.
Select the SAVE TO MEMORY on the Device adjust
page of the menu. Press the ENTER to save the data.
3-3. Signal Level Adjustment
Perform the following settings:
W/B:
LOW mode
INPUT-A:
10 steps
VIDEO:
100% COLOR BARS
CONTRAST:
80
BRIGHT:
50 (Initial value)
3-3-1. SUB-BRIGHT (NTSC) Adjustment
1.
Input the NTSC 100% color bars signal to the VIDEO
input.
2.
Connect oscilloscorp to TP5023 on the C board.
3.
Set the COLOR to 0.
3.
Enter the RGB-MTRX on the Device adjust of the
menu.
4.
Select the item of 03 SU BRT. Adjust the 
 or 
 key
so that the two bars at the center become flat.
3-3-2. SUB-CONT, HUE and COLOR
Adjustment
3-3-2-1. SUB-CONT. HUE and COLOR (VIDEO)
Adjustment
1.
Input the NTSC 100% color bars signal to the VIDEO input.
2.
Connect oscilloscope to TP5024 on the C board.
3.
Set the COLOR to 0.
4.
Enter the RGB-MTRX on the Device adjust of the
menu.
5.
Select the item of 08 YUV CONT, and adjust the
amplitude of the following waveform for 0.63 Vp-p.
6.
Set the COLOR to 50.
7.
Select the item of 09 YUV COL. Adjust the 
 or 
key so that the right and left bars are equal in level (A
portion).
8.
Select the item of 02 SUB HUE. Adjust the 
 or 
key so that the two bars in the middle are equal in level
(B portion).
<NTSC 100% Color Bars Signal>
* Be sure to set the GND level to bottom with DC 0.5V range.
A
B
Page of 92
Display

Click on the first or last page to see other RM-PJVW10 / VPL-VW10HT service manuals if exist.