Sony RM-PJ5 / VPL-CS21 / VPL-CX21 Service Manual ▷ View online
VPL-CX21/CS21
1-17
1-3-18. Lamp and Concave Lens-2
1
Concave lens
2
Slide the lamp box plate in the
direction of the arrow and remove it.
Concave lens
Precaution during concave lens.
1-18
VPL-CX21/CS21
1-3-19. Lamp
1-3-20. How to Install the Lamp and Concave Lens
m
. Install the concave lens after installing the lamp.
. Install the concave lens after installing the lamp.
(The lamp spring cannot be secured if the concave lens spring is installed first.)
. When the lamp is removed, the lamp cover and the net (lamp) are also removed at the same time.
When attaching the new lamp, be careful not to forget to attach the lamp cover and the net.
1
Three lamp springs
2
Lamp
2
Slit
1
Insert the net (lamp) into the slit.
3
Two dowels
4
Lamp cover
Lamp box
VPL-CX21/CS21
1-19
1-3-21. How to Dress the Lamp Lead and the Harness
Lamp
Draw out the lamp lead straight
down from the slit of the base.
down from the slit of the base.
Dress the terminal behind.
Long harness
Long harness
Louver
When installing the louver, be sure to draw
out the terminal from the opening of the louver.
out the terminal from the opening of the louver.
Secure the lamp lead and the harness (short) together.
Short harness
1-20
VPL-CX21/CS21
CN52
Set
NF Mount
NF Mount
SC Mount
CN 5P
Quick Access Assembly
(A-1501-849-A)
(A-1501-849-A)
RS-232C
Straight
cable
cable
PC
1-3-22. 3D GAMMA Quick Access Application Software
3D GAMMA QUICK ACCESS is a application software that saves or loads the 3D GAMMA DATA of
the projector connected to the computer using the communication function.
the projector connected to the computer using the communication function.
Feature of 3D Gamma Quick Access :
. It can read 3D gamma data from a set and save it in a file.
. It can write 3D gamma data in a PC into a set.
. It can write 3D gamma data in a PC into a set.
When the optical unit is replaced, load 3D gamma data recorded on the micro floppy disk, which is
supplied together with the optical unit, into a set using the application software.
File configuration :
Executable :
QuickAccess.exe
Readme File : readme_j.txt (Japanese)
readme_e.txt (English)
Software Acquisition :
Download the application software from the GSP website.
. Since this set has not RS-232C terminal, use the quick access assembly (A-1501-849-A).
1-4. Warning on Power Connection
Use the supplied power cord when you use the projector in your country/region. Otherwise, use a proper
power cord meeting the following specifications.
power cord meeting the following specifications.
The United
Continental
UK
Australia
Japan
States,
Europe,
Canada
Korea
Plug type
YP-11
YP-21
SP-61
B8
YP-13
Female end
YC-13L
YC-13L
YC-13L
C7-2
YC-13L
Cord type
SPT-2
H03VVH2-F
H03VVH2-F
H03VVH2-F
VCTFK
Rated Voltage &
10A/125V
2.5A/250V
2.5A/250V
2.5A/250V
7A/125V
Current
Safety approval
UL/CSA
VDE
BS
SAA
DENAN
Cord length (max.)
4.5 m
_
_
_
_
Click on the first or last page to see other RM-PJ5 / VPL-CS21 / VPL-CX21 service manuals if exist.