1-2
ENGLISH
JAPANESE
ENGLISH
JAPANESE
HDR-SR11/SR11E/SR12/SR12E_L2
1-2-3. Self-diagnosis Code Table
C
C
C
C
E
E
E
E
E
E
E
E
E
E
E
E
E
E
Block
Function
0
4
1
3
1
3
3
2
2
0
3
1
6
1
6
1
6
2
6
2
6
2
6
2
6
2
6
2
6
2
6
2
9
1
9
4
Detailed
Code
0
0
0
1
0
2
6
0
0
0
0
0
1
0
1
1
0
0
0
1
0
2
0
3
1
0
1
1
1
2
2
0
0
1
0
0
Symptom/State
Non-standard battery is used.
“Memory Stick Duo” is unformatted.
“Memory Stick Duo” is broken.
Disc access error
Difficult to adjust focus
(Cannot initialize focus)
Flash memory data are rewritten.
Drive fault
Zoom operations fault
(Cannot initialize zoom lens.)
The abnormalities in initialization of
the focus lens and the abnormalities in
initialization of the zoom lens occurred
simultaneously.
Handshake correction function does not
work well. (With PITCH angular
velocity sensor output stopped.)
Handshake correction function does not
work well. (With YAW angular velocity
sensor output stopped.)
Abnormality of IC for steadyshot.
IC for steadyshot and micro controller
communication abnormality among.
Shift lens initializing failure.
Shift lens overheating (Pitch)
Shift lens overheating (Yaw)
Abnormality of thermistor.
Abnormality when flash is being charged.
Fault of writing or erasing the
flash memory
Self-diagnosis Code
Repaired b
y:
Correction
Use the InfoLITHIUM battery.
Format the “Memory Stick Duo”.
Insert a new “Memory Stick Duo”.
Remove the power source. Reconnect it again and operate your
camcorder again
Retry turn the power on by the power switch. If it does not
recover, check the focus MR sensor of lens block (pin w;, wa of
CN5103 on the LD-230 board). If it is OK, check the focus
motor drive IC (IC5201 on the LD-230 board).
Make flash memory data correct value. (Note 1)
Inspect or replacement of the hard disk drive.
Inspect the lens block zoom MR sensor (pin qh, qj of CN5103
on the LD-230 board) when zooming is performed when the
zoom lever is operated, and the zoom motor drive circuit
(IC5201 on the LD-230 board) when zooming is not performed.
Check both C: 32: 60 and E: 61: 10 of the self-diagnosis code.
Inspect PITCH angular velocity sensors (SE9001 on the FR-278
board) peripheral circuits.
Inspect YAW angular velocity sensors (SE9002 on the FR-278
board) peripheral circuits.
Refer to [1-3-1. E : 62 : 02 (Abnormality of IC for Steadyshot)
Occurred].
Inspect the steadyshot circuit (IC5501 on the LD-230 board).
Replacement of lens block. If an error occurs again, replace the
LD-230 board. (Note 2)
Refer to [1-3-2. E : 62 : 11 (Shift Lens Overheating (Pitch))
Occurred].
Refer to [1-3-3. E : 62 : 12 (Shift Lens Overheating (Yaw))
Occurred].
Refer to [1-3-4. E : 62 : 20 (Abnormality of Thermistor)
Occurred].
Checking of flash unit or replacement of flash unit.
Inspect the flash memory (IC2101 on the VC-516 board).
Note 1 : Refer to Service Manual, ADJ (“1-3. DESTINATION DATA WRITE”).
Note 2 : When the lens block was replaced, execute the necessary adjustment items referring to Service Manual, ADJ.
After the adjustment, make sure with the STEADYSHOT turned ON that the steadyshot functions appropriately in the
handheld operation.
1-3
ENGLISH
JAPANESE
ENGLISH
JAPANESE
HDR-SR11/SR11E/SR12/SR12E_L2
1-3. METHOD OF COPING WITH SHIFT LENS ERROR
about 330 msec
Fig. 2
Change in output voltage of R5549 on the LD-230 board
Note: The length of low section will vary a little depending on the
conditions.
1-3-1. E : 62 : 02 [Abnormality of IC for Steadyshot] Occurred
Order
Procedure
1
Turn the power OFF.
2
While measuring with an oscilloscope the output voltage of R5549 in the periphery of IC5501 on the LD-230 board, turn the
power ON to check that the output voltage immediately after the power on change as shown in Fig. 2.
3
If the output voltage change as shown in Fig. 2, replace the lens block (Note). If it does not change as shown in Fig. 2, inspect
the camera control circuit (IC1301 of VC-516 board) periphery.
Note: When the lens block was replaced, execute a necessary adjustment items referring to Service Manual, ADJ.
After the adjustment, make sure with the STEADYSHOT turned ON that the steadyshot functions appropriately in the
handheld operation.
VC-516 BOARD (SIDE A)
LD-230 BOARD (SIDE A)
IC5501
R5534
R5549
R5526
C5513
4
R5525
31
R5538
R5549: No Mount
            (Short Land)
IC1301
Fig. 1
Measurement points on the LD-230 board and the VC-516 board
1-4
ENGLISH
JAPANESE
ENGLISH
JAPANESE
HDR-SR11/SR11E/SR12/SR12E_L2
1-3-2. E : 62 : 11 [Shift Lens Overheating (Pitch)] Occurred
Connect by the SeusEX and perform the following process.
Order Block Page Address Data
Procedure
1
11
80
7430
01
Write the data. (After it starts, set it before caution is displayed.)
2
11
8E
F946
F0
Write the data.
3
11
8E
F948
01
Write the data. (Note 1)
4
11
8E
F948
00
Write the data.
5
11
8E
F946
10
Write the data.
6
11
8E
F948
01
Write the data. (Note 1)
7
11
8E
F948
00
Write the data.
8
11
80
7430
00
Write the data.
9
Check if the shift lens moves while setting the order 2 to 7. If the shift lens does not move,
replace the lens block (Note 2). When the shift lens moved, proceed to the order 10.
10
While setting the order 2 to 7, measure with an oscilloscope the output voltage of R5526 in the
periphery of IC5501 on the LD-230 board to check the output voltage varies.
11
If the output voltage does not vary, replace the lens block (Note 2). When the output voltage
varied, proceed to the order 12.
12
Turn the power OFF.
While measuring with an oscilloscope the output voltage of R5549 in the periphery of IC5501
13
on the LD-230 board, turn the power ON to check that the output voltage immediately after the
power on change as shown in Fig. 2.
If the output voltage change as shown in Fig. 2, replace the lens block (Note 2). If it does not
14
change as shown in Fig. 2, inspect the camera control circuit (IC1301 of VC-516 board)
periphery.
Note 1: Finish this operation within 10 seconds. If it is likely to take more than 10 seconds, set block: 11, page: 8E, address:
F948, data: 00, and then retry.
Note 2: When the lens block was replaced, execute the necessary adjustment items referring to Service Manual, ADJ.
After the adjustment, make sure with the STEADYSHOT turned ON that the steadyshot functions appropriately in the
handheld operation.
1-5
ENGLISH
JAPANESE
ENGLISH
JAPANESE
HDR-SR11/SR11E/SR12/SR12E_L2
1-3-3. E : 62 : 12 [Shift Lens Overheating (Yaw)] Occurred
Connect by the SeusEX and perform the following process.
Order Block Page Address Data
Procedure
1
11
80
7430
01
Write the data. (After it starts, set it before caution is displayed.)
2
11
8E
F947
F0
Write the data.
3
11
8E
F949
01
Write the data. (Note 1)
4
11
8E
F949
00
Write the data.
5
11
8E
F947
10
Write the data.
6
11
8E
F949
01
Write the data. (Note 1)
7
11
8E
F949
00
Write the data.
8
11
80
7430
00
Write the data.
9
Check if the shift lens moves while setting the order 2 to 7. If the shift lens does not move,
replace the lens block (Note 2). When the shift lens moved, proceed to the order 10.
10
While setting the order 2 to 7, measure with an oscilloscope the output voltage of R5534 in the
periphery of IC5501 on the LD-230 board to check the output voltage varies.
11
If the output voltage does not vary, replace the lens block (Note 2). When the output voltage
varied, proceed to the order 12.
12
Turn the power OFF.
While measuring with an oscilloscope the output voltage of R5549 in the periphery of IC5501
13
on the LD-230 board, turn the power ON to check that the output voltage immediately after the
power on change as shown in Fig. 2.
If the output voltage change as shown in Fig. 2, replace the lens block (Note 2). If it does not
14
change as shown in Fig. 2, inspect the camera control circuit (IC1301 of VC-516 board)
periphery.
Note 1: Finish this operation within 10 seconds. If it is likely to take more than 10 seconds, set block: 11, page: 8E, address:
F949, data: 00, and then retry.
Note 2: When the lens block was replaced, execute the necessary adjustment items referring to Service Manual, ADJ.
After the adjustment, make sure with the STEADYSHOT turned ON that the steadyshot functions appropriately in the
handheld operation.
1-3-4. E : 62 : 20 [Abnormality of Thermistor] Occurred
Order
Procedure
1
Turn the power ON.
2
Confirm the connections of flexible flat cables and connectors between the lens block and LD-230 board, LD-230 board and
VC-516 board.
3
In case of no malfunction of connections, replace the lens block with new one. (Note) When the error has occurred in spite of the
lens replacement, replace LD-230 board with new one.
Note: When the lens block was replaced, execute the necessary adjustment items referring to Service Manual, ADJ.
After the adjustment, make sure with the STEADYSHOT turned ON that the steadyshot functions appropriately in the
handheld operation.