DOWNLOAD Sony HDR-HC3 / HDR-HC3E / HDR-HC3EK / HDR-HC3K (serv.man4) Service Manual ↓ Size: 730.51 KB | Pages: 99 in PDF or view online for FREE

Model
HDR-HC3 HDR-HC3E HDR-HC3EK HDR-HC3K (serv.man4)
Pages
99
Size
730.51 KB
Type
PDF
Document
Service Manual
Brand
Device
Movie / SECTION 6 ADJUSTMENTS
File
hdr-hc3-hdr-hc3e-hdr-hc3ek-hdr-hc3k-sm4.pdf
Date

Sony HDR-HC3 / HDR-HC3E / HDR-HC3EK / HDR-HC3K (serv.man4) Service Manual ▷ View online

6-35
HDR-HC3/HC3E/HC3K/HC3EK_ADJ
8.
Flange Back Check (Using the Siemens star)
Subject
Siemens star
(2.0 m from the front of the lens)
(Illuminance: approx. 200 lux)
Measurement Point
Check operation on monitor TV
Measuring Instrument
Specified value
Focused at the TELE end and WIDE
end
Note 1:
Check that the data of page: 0, address: 10 is “00”.
Switch setting
1) POWER ............................................. CAMERA-TAPE mode
2) NIGHT SHOT .................................................................. OFF
3) REC FORMAT (Menu setting) ............................. HDV1080i
Note 2:
When the auto focus is ON, the lens can be checked if it
is focused or not by observing the data on the page: 1 of
the adjusting remote commander.
1 : 00 : XX
Odd: Focused
Even: Unfocused
Preparations before adjustments:
1) Place the Siemens star 2.0 m from the front of the lens.
2) To open the IRIS, decrease the luminous intensity to the Si-
emens star up to a point before noise appear on the image.
Checking method:
Order Page Address Data
Procedure
1
6
40
01
2
6
41
01
3
6
4D
40
4
Shoot the Siemens star with
the zoom TELE end.
5
Turn on the auto focus.
6
0
03
0F
7
1
Check that the lens is
focused. (Note 2)
8
6
21
10
9
Shoot the Siemens star with
the zoom WIDE end.
10
Observe the TV monitor and
check that the lens is
focused.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
21
00
2
6
40
00
3
6
41
00
4
6
4D
40
5
0
03
00
7.
Flange Back Check
(Using the flange back adjustment jig)
Subject
Flange back adjustment jig
(Illuminance: approx. 200 lux)
Measurement Point
Check operation on monitor TV
Measuring Instrument
Specified value
Focused at the TELE end and WIDE
end
Note:
Check that the data of page: 0, address: 10 is “00”.
Switch setting
1) POWER ............................................. CAMERA-TAPE mode
2) NIGHT SHOT .................................................................. OFF
3) REC FORMAT (Menu setting) ............................. HDV1080i
Preparations before adjustments:
1) Install the flange back adjustment jig so that the distance be-
tween it and the front of lens of camera is less than 3 cm.
2) To open the IRIS, decrease the luminous intensity to the chart
of the flange back adjustment jig up to a point before noise
appear on the image. (approx. 200 lux)
3) Check that the center of chart meets the center of shot image
screen with the zoom lens at TELE end and WIDE end respec-
tively.
Checking method:
Order Page Address Data
Procedure
1
6
40
01
2
6
41
01
3
6
4D
40
4
Shoot the chart with the
zoom TELE end.
5
6
2C
02
6
Check that the lens is
focused.
7
Shoot the chart with the
zoom WIDE end.
8
Check that the lens is
focused.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
2C
00
2
6
40
00
3
6
41
00
4
6
4D
00
Ver. 1.2  2008.04
6-36
HDR-HC3/HC3E/HC3K/HC3EK_ADJ
10. Mechanical Shutter Adjustment 
RadarW
RadarW
RadarW
Adjust the close time and loss time every F number of the me-
chanical shutter and the high-speed shutter correction value to
correct the luminous exposure.
Adjustment Page
69
Adjustment Address
A0 to B5
Note 1:
 If reading/writing data on pages 69, set data: 06 to page:
0, address: 10, and then select pages: 9. By this data set-
ting, the pages 69 can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 0, address: 10, and set data: 06.
3) Input the following data to page: 69, address: A0 to B5.
Note 2:
Press the PAUSE (Write) button of the adjustment re-
mote commander each time to set data.
Address
Data
NTSC PAL
A0
0B
09
A1
C1
CA
A2
08
06
A3
44
E6
A4
06
05
A5
97
7F
A6
05
04
A7
5B
75
A8
04
03
A9
2B
80
AA
54
55
AB
65
65
AC
63
64
AD
5C
5C
AE
4B
4B
AF
21
22
B0
80
80
B1
80
80
B2
80
80
B3
80
80
B4
80
80
B5
80
80
4) Select page: 0, address: 10, and set data: 00.
5) Select page: 0, address: 01, and set data: 00.
9.
F No. & ND Light Quality Standard Data Input
RadarW
RadarW
RadarW
Correct the lens iris and dispersion of the ND filter light quantity.
Adjustment Page
69
Adjustment Address
E0 to EF
Note 1:
If reading/writing data on pages 69, set data: 06 to page:
0, address: 10, and then select pages: 9. By this data set-
ting, the pages 69 can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 0, address: 10, and set data: 06.
3) Input the following data to page: 69, address: E0 to EF.
Note 2:
Press the PAUSE (Write) button of the adjustment re-
mote commander each time to set data.
Address
Data
NTSC PAL
E0
00
00
E1
00
00
E2
00
00
E3
00
00
E4
00
00
E5
00
00
E6
00
00
E7
00
00
E8
00
00
E9
00
00
EA
00
00
EB
00
00
EC
00
00
ED
00
00
EE
00
00
EF
00
00
4) Select page: 0, address: 10, and set data: 00.
5) Select page: 0, address: 01, and set data: 00.
6-37
HDR-HC3/HC3E/HC3K/HC3EK_ADJ
Address
Data
NTSC PAL
DA
04
04
DB
32
27
DC
00
00
DD
51
54
DE
FF
FF
DF
CA
DC
E0
FF
FF
E1
D7
DD
E2
04
04
E3
28
1B
E4
FF
FF
E5
DD
F9
E6
FF
FF
E7
E7
EA
E8
00
00
E9
94
91
EA
03
03
EB
E1
D9
11. Linear Matrix Adjustment 
RadarW
RadarW
RadarW
RadarW
RadarW
Adjust the matrix coefficient for compensating the variation in
spectral sensitivity.
Adjustment Page
6F
Adjustment Address
C8 to EB
Note 1:
If reading/writing data on pages 6F, set data: 06 to page:
0, address: 10, and then select pages: F. By this data set-
ting, the pages 6F can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 0, address: 10, and set data: 06.
3) Input the following data to page: 6F, address: C8 to EB.
Note 2:
Press the PAUSE (Write) button of the adjustment remote
commander each time to set data.
Address
Data
NTSC PAL
C8
03
03
C9
CF
D9
CA
FF
FF
CB
B0
AD
CC
00
00
CD
33
24
CE
00
00
CF
27
22
D0
03
03
D1
D2
E2
D2
00
00
D3
25
09
D4
00
00
D5
13
12
D6
FF
FF
D7
6D
6D
D8
04
04
D9
1C
28
4) Select page: 0, address: 10, and set data: 00.
5) Select page: 0, address: 01, and set data: 00.
6-38
HDR-HC3/HC3E/HC3K/HC3EK_ADJ
12. Picture Frame Setting
(AWB adjustment frame)
Subject
Clear chart
(AWB adjustment frame)
(1 m (PTB-450) or 40 cm (PTB-
1450) from the front of lens)
Measurement Point
Video terminal of A/V jack
(75 
Ω terminated)
Measuring Instrument
Monitor TV (16:9)
Specified Value
Only the clear chart must be shot
(entire screen is white).
Note 1:
Perform “Hall Adjustment” and “Flange Back Adjust-
ment” before this adjustment.
Note 2:
Check that the data of page: 0, address: 10 is “00”.
Switch setting
1) POWER ............................................. CAMERA-TAPE mode
2) NIGHT SHOT .................................................................. OFF
3) DIGITAL ZOOM (Menu setting) .................................... OFF
4) STEADY SHOT (Menu setting) ..................................... OFF
5) FOCUS (Menu Setting) ......................................... MANUAL
6) REC FORMAT (Menu setting) ............................. HDV1080i
Setting method:
Order Page Address Data
Procedure
1
6
4D
40
2
Shoot the color bar chart.
3
Adjust the camera direction
and zoom to set a picture
frame so that color bars on
the chart can be shot on the
entire screen. (Refer to Fig.
6-1-12)
4
Remove the color bar chart
from the pattern box, and
install the clear chart.
5
Check that whole of the
screen is white.
6
In the adjustment performed
later, when the “AWB
adjustment frame” is used,
set the zoom and focus to this
position.
How to read the XH, XL, YH and YL data:
Order Page Address Data
Procedure
1
0
03
18
2
1
Read XH data and XL data.
(Note 3)
3
0
03
22
4
1
Read YH data and YL data.
(Note 3)
Note 3:
The right four digits of the page: 1 displayed data of the
adjusting remote commander.
1:XX : XX
XL or YL data
XH or YH data
Check on the monitor TV (Underscanned mode)
Fig. 6-1-12
How to reset the zoom and focus when they deviated:
If the zoom and focus deviated due to some reason, reset them in
the following method.
Order Page Address Data
Procedure
1
6
4D
40
2
6
90
XL
3
6
91
XH
4
6
92
YL
5
6
93
YH
6
6
01
79
Press PAUSE (Write) button.
How to release the picture frame setting:
Order Page Address Data
Procedure
1
6
4D
00
2
6
01
00
Press PAUSE (Write) button.
3
6
90
00
4
6
91
00
5
6
92
00
6
6
93
00
Color bar chart picture frame
Monitor TV picture frame
Page of 99
Display

Click on the first or last page to see other HDR-HC3 / HDR-HC3E / HDR-HC3EK / HDR-HC3K (serv.man4) service manuals if exist.