1-5. SELF-DIAGNOSIS  FUNCTION
1-5-1. Self-diagnosis Function
When problems occur while the unit is operating, the self-diagnosis
function starts working, and displays on the viewfinder or LCD
screen what to do.
Details of the self-diagnosis functions are provided in the Instruction
manual.
1-5-2. Self-diagnosis Display
When problems occur while the unit is operating, the counter of the
viewfinder or LCD screen shows a 4-digit display consisting of an
alphabet and numbers, which blinks at 3.2 Hz. This 5-character
display indicates the “repaired by:”, “block” in which the problem
occurred, and “detailed code” of the problem.
1 1
3 1
C
Repaired by:
Refer to “1-5-3. Self-diagnosis Code Table”.
Indicates the appropriate
step to be taken.
E.g.
31 ....Reload the tape.
32 ....Turn on power again.
Block
Detailed Code
Blinks at 3.2Hz
C : Corrected by customer
H : Corrected by dealer
E : Corrected by service
engineer
Viewfinder or LCD screen
C : 3 1 : 1 1
1-4. USING  SERVICE  JIG
Connect the CPC-13 jig (J-6082-443-A) to the CN1004 on the VC-543 board.
Pin No.
Signal Name
Pin No.
Signal Name
1 (20)
REG_GND
11 (10)
EEP_SO_C
2 (19)
RF_MON
12 (9)
EEP_SO_S
3 (18)
REG_GND
13 (8)
EEP_SCK_C
4 (17)
SWP
14 (7)
EEP_SCK_S
5 (16)
FRRV
15 (6)
D_2.8V
6 (15)
REG_GND
16 (5)
MD2_C
7 (14)
GND
17 (4)
MD2
8 (13)
GND
18 (3)
XCS_MC_FLASH_C
9 (12)
EEP_SI_C
19 (2)
XCS_MC_FLASH
10 (11)
EEP_SI_S
20 (1)
XSYS_RST
Note: The pin number in (  ) is test terminal number of
CN1004 on the VC-543 board.
1
20
CN1004
VC-543 BOARD (SIDE B)
11
10
20
1
1
20
CPC-13
(J-6082-443-A)
1-3
ENGLISH
JAPANESE
ENGLISH
JAPANESE
HDR-FX1000/FX1000E_L2
1-5-3. Self-diagnosis Code Table
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
Block
Function
0
4
0
6
2
1
2
2
3
1
3
1
3
1
3
1
3
1
3
1
3
1
3
1
3
1
3
1
3
1
3
1
3
1
3
1
3
2
3
2
3
2
3
2
3
2
3
2
3
2
3
2
3
2
3
2
3
2
Detailed
Code
0
0
0
0
0
0
0
0
1
0
1
1
2
0
2
1
2
2
2
3
2
4
3
0
4
0
4
2
7
2
9
7
9
8
9
9
1
0
1
1
2
0
2
1
2
2
2
3
2
4
3
0
4
0
4
2
6
0
Symptom/State
Non-standard battery is used.
The battery is too hot.
Condensation.
Video head is dirty.
LOAD direction. Loading does not
complete within specified time
UNLOAD direction. Loading does not
complete within specified time
T reel side tape slacking when unloading.
S reel side tape slacking when unloading.
T reel fault.
S reel fault.
T reel and S reel  FG short fault.
FG fault when starting capstan.
FG fault when starting drum.
FG fault during normal drum operations.
Retry fault when catching one’s finger
in cassette compartment.
Vector fault (Judgement with the set
state that is impossible actually for fault
of sensors.)
Vector fault (Judgement with the set
state that is impossible actually for fault
of sensors.)
Vector fault (Judgement with the set
state that is impossible actually for fault
of sensors.)
LOAD direction loading motor time-
out.
UNLOAD direction loading motor
time-out.
T reel side tape slacking when
unloading.
S reel side tape slacking when
unloading.
T reel fault.
S reel fault.
T reel and S reel  FG short fault.
FG fault when starting capstan.
FG fault when starting drum.
FG fault during normal drum
operations.
Difficult to adjust focus
(Cannot initialize focus.)
Self-diagnosis Code
Repaired b
y:
Correction
Use the InfoLITHIUM battery.
Replace the battery or remove it and put it in cool place.
Remove the cassette, and insert it again after one hour.
Clean with the optional cleaning cassette.
Load the tape again, and perform operations from the beginning.
Load the tape again, and perform operations from the beginning.
Load the tape again, and perform operations from the beginning.
Load the tape again, and perform operations from the beginning.
Load the tape again, and perform operations from the beginning.
Load the tape again, and perform operations from the beginning.
Load the tape again, and perform operations from the beginning.
Load the tape again, and perform operations from the beginning.
Load the tape again, and perform operations from the beginning.
Load the tape again, and perform operations from the beginning.
Load the tape again, and perform operations from the beginning.
Load the tape again, and perform operations from the beginning.
Load the tape again, and perform operations from the beginning.
Load the tape again, and perform operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
If it does not recover, inspect the focus MR sensor of lens drive
block (Pin q;, qs of CN5002 on the VC-543 board).
If not faulty, inspect the focus motor drive circuit
(IC6001 on the VC-543 board).
1-4
ENGLISH
JAPANESE
ENGLISH
JAPANESE
HDR-FX1000/FX1000E_L2
C
C
C
C
E
E
E
E
E
E
E
E
E
E
E
E
Block
Function
3
2
3
2
3
2
3
2
2
0
6
1
6
1
6
1
6
2
6
2
6
2
6
2
6
2
6
2
6
2
6
2
Detailed
Code
7
2
9
7
9
8
9
9
0
0
1
0
1
1
3
0
0
0
0
1
0
2
0
3
1
0
1
1
1
2
2
0
Symptom/State
Retry fault when catching one’s finger
in cassette compartment.
Vector fault (Judgement with the set
state that is impossible actually for fault
of sensors.)
Vector fault (Judgement with the set
state that is impossible actually for fault
of sensors.)
Vector fault (Judgement with the set
state that is impossible actually for fault
of sensors.)
EEPROM data are rewritten.
Zoom operations fault
(Cannot initialize zoom lens.)
Focus lens initializing failure and zoom
lens initializing failure occur simulta-
neously.
Reset position detect error when
stepper iris is initialized.
Steadyshot function does not work well.
(With pitch angular velocity sensor output
stopped.)
Steadyshot function does not work well.
(With yaw angular velocity sensor output
stopped.)
Abnormality of IC for steadyshot.
IC for steadyshot and micro controller
communication abnormality among.
Shift lens initializing failure
Shift lens overheating (Pitch)
Shift lens overheating (Yaw)
Abnormality of lens thermister
Self-diagnosis Code
Repaired b
y:
Correction
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Make EEPROM data correct value.
Inspect the zoom MR sensor of lens drive block (Pin es, ef of
CN5002 on the VC-543 board) when zooming is performed when
the zoom switch is operated and the zoom motor drive circuit
(IC6001 on the VC-543 board) when zooming is not performed.
Check both C: 32: 60 and E: 61: 10 of the self-diagnosis code.
Turn on the power and set to T (telephoto) end by rotating the
ZOOM manual ring. While observing the iris blades in the lens,
turn on the power again and check the iris blades in the lens
work properly. Inspect the iris drive motor of lens drive block
(Pin qh to ql of CN5002 on the VC-543 board), when the iris
does not operate. Inspect the iris reset sensor of lens drive block
(Pin qd to qg of CN5002 on the VC-543 board), when the iris
operate.
Inspect pitch angular velocity sensor (SE8501 on the GY-014
board) peripheral circuits.
Inspect yaw angular velocity sensor (SE8502 on the GY-014
board) peripheral circuits.
Inspect the steadyshot circuit (IC7001 on the VC-543 board). If
it does not recover, replace the VC-543 board. (Note) If an error
occurs again, replace the lens block.
Inspect the steadyshot circuit (IC7001 on the VC-543 board).
Inspect the EEPROM (IC4202 on the VC-543 board). If it does
not recover, replace the VC-543 board. (Note) If an error occurs
again, replace the lens block.
Inspect the IC7001 and peripheral circuits on the VC-543 board.
If it does not recover, replace the VC-543 board. (Note) If an
error occurs again, replace the lens block.
Inspect the IC7001 and peripheral circuits on the VC-543 board.
If it does not recover, replace the VC-543 board. (Note) If an
error occurs again, replace the lens block.
Inspect the IC7001 and peripheral circuits on the VC-543 board.
If it does not recover, replace the VC-543 board. (Note) If an
error occurs again, replace the lens block.
Note: When replacing the VC-543 board, remove the EEPROM (IC4202) from the VC-543 board that is going to be repaired. Install the removed EEPROM
(IC4202) to the replaced VC-543 board.
1-5
ENGLISH
JAPANESE
ENGLISH
JAPANESE
HDR-FX1000/FX1000E_L2
1. SERVICE  NOTE
1-1. 修理時の電源供給について
本機では,安定化電源(8.4Vdc)からバッテリ端子に電源を供給した場合,約10秒後にシャットオフし,動作しなくなります。
これを避けるため,下記の方法を用いてください。
方法:
ACアダプタ(AC-L100)を使用する。
1-2. イジェクトしない時のカセット取出し方法(強制イジェクト)
1
 電源を外す。
2
ねじ2本とCS蓋 (24000) 組立を外す。
3
安定化電源より+4.5Vをローディングモータに加え,アンローディングさせる。
1-3. 強制電源ONモードの設定
調整リモコン(RM-95またはNEW LANC JIG)を使用して,電源を入れることが出来ます。
VTR操作は調整リモコンで行えます。
1-3-1.
強制カメラ電源ONモードの設定
1) ページ:0,アドレス:01にデータ:01をセット。
2) ページ:A,アドレス:10にデータ:01をセットしPAUSE(Write)ボタンを押す。
1-3-2.
強制VTR電源ONモードの設定
1) ページ:0,アドレス:01にデータ:01をセット。
2) ページ:A,アドレス:10にデータ:02をセットしPAUSE(Write)ボタンを押す。
1-3-3.
強制電源ONモードの解除
1) ページ:0,アドレス:01にデータ:01をセット。
2) ページ:A,アドレス:10にデータ:00をセットしPAUSE(Write)ボタンを押す。
3) ページ:0,アドレス:01にデータ:00をセット。
安定化電源 (+4.5Vdc)
ローディングモータ
CS蓋 (24000) 組立
Page of 123