Sony DCR-VX2100 / DCR-VX2100E (serv.man2) Service Manual ▷ View online
2-8
DCR-VX2100/VX2100E
2-6. CABINET (R) BLOCK ASSEMBLY
CK-140
Board
1
Screw
(M2
×
5),
spring bolt
5
Screw
(M2
×
5),
spring bolt
4
Two screws
(M2
×
5),
spring bolt
6
Two screws
(M2
×
5),
spring bolt
7
Cabinet (R) block assembly
Cabinet (R) block assembly
CK-140 board
3
CF ornamental plate
2
Claw
AC POWER
ADAPTOR
ADAPTOR
AC IN
Adjustment remote
commander (RM-95)
commander (RM-95)
LANC
jack
jack
[CK-140 BOARD SERVICE POSITION]
CPC-13 jig
(J-6082-443-A)
(J-6082-443-A)
2-7. CABINET BOTTOM ASSEMBLY
2
Four screws
(M2
×
5),
lock ace
4
Two screws
(M2
×
5),
lock ace
1
Two tapping screws
(B2
×
5)
3
Two tapping screws
(B2
×
5)
5
FBS cover
4
Cabinet (bottom)
3
Tripod table
5
Cabinet bottom
assembly
1
FP-189
flexible board (6P)
2
FP-189
flexible board
REMOVING THE FBS COVER
2-9
DCR-VX2100/VX2100E
2-8. BATTERY PANEL BLOCK ASSEMBLY (MK-016, KP-013, MS-209 BOARDS)
LA-028
board
board
M
S-209
Board
A
A
1
FP-190
flexible board (20P)
2
DC-IN connector (3P)
3
Battery terminal board (4P)
5
Screw (M2
×
5),
lock ace
8
Screw (M2
×
5),
lock ace
9
CPC cover
q;
Battery panel
block assembly
4
Screw (M2
×
3),
lock ace
6
Two screws
(M2
×
5),
lock ace
7
Two screws
(M2
×
5),
lock ace
1
Two tapping screws (B2
×
5)
8
Two tapping
screws (B2
×
5)
q;
Two tapping
screws (B2
×
5)
qa
DC jack retainer
qs
DC-IN connector
9
MS holder assembly
2
MK retainer
3
MK-016 board
When installing it,
align the switch position
as shown.
align the switch position
as shown.
5
KP-013 board
7
MS-209 board
4
Screw (M2
×
3),
lock ace
6
Two screws
(M2
×
3),
lock ace
PRECAUTION DURING
INSTALLATION
INSTALLATION
2-9. EVF BLOCK ASSEMBLY
LA
-0
28
bo
ard
2
Screw (M2
×
3),
lock ace
6
Two screws
(M2
×
3),
lock ace
7
EVF block assembly
3
Claw
5
Flexible clamp
4
Peel off the area
shown by shading.
1
FP-193
flexible board (27P)
2-10
DCR-VX2100/VX2100E
2-10.LA-028, DD-216, VC-358, JK-267 BOARDS, MECHANISM DECK
LA-028
Board
Board
LA-028
Board
LA-028
Board
Board
DD-
216
216
VC-358
Board
Board
A
A
B
B
D
D
C
C
1
Screw (M2
×
3),
lock ace
8
Screw (M2
×
3),
lock ace
9
LA joint
2
Flexible retainer
6
Three screws
(M2
×
3),
lock ace
2
Two screws
(M2
×
3),
EG grip
1
Two screws
(M2
×
3),
lock ace
qa
Two screws
(M2
×
3),
lock ace
qs
Two screws
(M2
×
3),
lock ace
qd
Two claws
qf
JK frame
qg
JK-267 board
3
Three screws
(M2
×
3), lock ace
5
Two step
screws (M2)
7
MD frame assembly
q;
Mechanism deck
9
LD outer lid
6
Step
screw (M2)
8
Two screws (M2
×
2),
lock ace
2
DD-216 board
4
VC-358 board
3
Two screws
(M2
×
3),
EG grip
4
Two screws
(M2
×
5),
spring bolt
5
7
LA-028 board
(LA-028 board)
3
FP-188
flexible board (6P)
4
Flexible board (39P)
(from zoom lens assembly)
1
CD-512 board (50P)
5
Flexible board (27P)
(from VAP assembly)
2-11
DCR-VX2100/VX2100E
2-11.LENS BLOCK ASSEMBLY, CENTER FRAME ASSEMBLY
1
Screw (M2
×
3),
lock ace
q;
Two screws (M2
×
4),
lock ace
qa
Two screws (M2
×
3),
lock ace
qs
FP-188 flexible board (6P)
FP-188 flexible board
qd
Center frame assembly
Center frame assembly
6
Screw
(M2
×
3),
lock ace
7
Two screws
(M2
×
5),
EG grip
8
Two screws
(M2
×
5),
EG grip
4
Screw (M2
×
3),
lock ace
5
CJ-064 harness
9
Lens block assembly
Lens block assembly
2
Tapping screw
(B2
×
5)
3
CCD cover
When installing it.
Align the swich position.
Align the swich position.
PRECAUTION DURING INSTALLATION
VC-358
Board
LA
-028
Board
[SERVICE POSITION TO CHECK THE CAMERA SECTION]
Adjustment remote
commander (RM-95)
commander (RM-95)
AC POWER
ADAPTOR
ADAPTOR
AC IN
DC-IN
connector (3P)
(1-794-637-21)
connector (3P)
(1-794-637-21)
DD-216 board
Mechanism deck
VC-358 board
LA-028 board
JK-267 board
Monitor TV
LANC jack
VIDEO jack
Extension cable
(J-6082-496-A) (50P)
(J-6082-496-A) (50P)
CD-512 board (50P)
Flexible board (39P)
(from zoom lens assembly)
(from zoom lens assembly)
Flexible board (27P)
(from VAP assembly)
(from VAP assembly)
Lens block assembly
FP-186 flexible board (80P)
Insert the FP-186 flexible board in the opposite
direction to the normal insertion direction.
Insert the FP-186 flexible board in the opposite
direction to the normal insertion direction.
FP-191 flexible board (60P)
Insert the FP-191 flexible board in the opposite
direction to the normal insertion direction.
Insert the FP-191 flexible board in the opposite
direction to the normal insertion direction.
Connection to Check the CAMERA Section
To check the CAMERA Section, set the CAMERA to the "forced CAMERA power ON" mode.
Setting the “Forced CAMERA Power ON” mode
1)
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: D, address: 10, set data: 01, and press
the PAUSE button of the adjustment remote
commander.
the PAUSE button of the adjustment remote
commander.
Exiting the “Forced CAMERA Power ON” mode
1)
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: D, address: 10, set data: 00, and press
the PAUSE button of the adjustment remote
commander.
the PAUSE button of the adjustment remote
commander.
3)
Select page: 0, address: 01, and set data: 00.