Sony DCR-TRV75 / DCR-TRV75E / DCR-TRV80 / DCR-TRV80E (serv.man4) Service Manual ▷ View online

6-18
DCR-TRV75/TRV75E/TRV80/TRV80E
1-2-4.
INITIALIZATION OF E, F, 1E, 1F PAGE DATA
Note:
When reading or writing the E, F page data, select page: 0, address:
10, and set data: 00.
When reading or writing the 1E, 1F page data, select page: 0, address:
10, and set data: 01, then select E or F page. The 1E or 1F page can
be chosen by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
1. Initializing the E, F, 1E, 1F Page Data
Note1:
If “Initializing the E, F, 1E, 1F Page Data” is performed, all data
of the E page, F page, 1E page and 1F page will be initialized. (It
is impossible to initialize a single page.)
Note2:
If the E, F, 1E, 1F page data has been initialized, following
adjustments need to be performed again.
1) Modification of E, F, 1E, 1F page data
2) Camera system adjustments
Note3:
The power supply voltage must be 6.3 ± 0.1Vdc.
Note4:
NTSC model: DCR-TRV75/TRV80
PAL model: DCR- TRV75E/TRV80E
Adjusting page
E
Adjusting Address
00 to FF
Adjusting page
F
Adjusting Address
10 to FF
Adjusting page
1E
Adjusting Address
00 to FF
Adjusting page
1F
Adjusting Address
00 to FF
Initializing Method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
0
10
00
Set the data.
3
6
01
Set the following data, and press
PAUSE button.
2D (NTSC), 2F (PAL)
4
6
03
01
Set the data, and press PAUSE
button.
5
6
02
Check that the data changes to
“01”.
6
Perform “Modification of E, F,
1E, 1F Page Data”.
2. Modification of E, F, 1E, 1F Page Data
If the E, F, 1E, 1F page data has been initialized, change the data of
the “Fixed data-2” address shown in the following table by manual
input.
Modifying Method:
1)
Before changing the data, select page: 0, address: 01, and set
data: 01.
2)
When changing the E, F page data, select page: 0, address: 10,
and set data: 00.
3)
When changing the 1F page data, select page: 0, address: 10,
and set data: 01.
After completing the modification of 1F page data, reset the
data of this address to “00”.
4)
New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note:
If copy the data built in the different model, the camcorder may
not operate.
5)
When changing the data, press the PAUSE button of the
adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
6)
Check that the data of adjustment addresses is the initial value.
If not, change the data to the initial value.
Processing after Completing Modification of E, F, 1E, 1F Page data
Order Page Address Data
Procedure
1
0
10
00
Set the data.
2
2
00
29
Set the data.
3
2
01
29
Set the data, and press PAUSE
button.
4
Perform “54MHz/67.5MHz
Origin Osc. Adjustment” of the
camera system adjustment.
6-19
DCR-TRV75/TRV75E/TRV80/TRV80E
3. E Page Table
Note1:
The data of page: 0, address: 10 must be “00”.
Note2:
Fixed data-1: Initialized data. (Refer to “1. Initializing the E, F,
1E, 1F Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of E, F,
1E, 1F Page Data”).
4. F Page Table
Note1:
The data of page: 0, address: 10 must be “00”.
Note2:
Fixed data-1: Initialized data. (Refer to “1. Initializing the E, F,
1E, 1F Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of E, F,
1E, 1F Page Data”).
Table. 6-1-10.
Address
Remark
00 to 04
05
06 to 07
08
09
0A
0B
0C to 0D
0E
0F
10
11 to 1C
1D
1E to 1F
20
21
22
23
24 to 46
47
48 to 52
53
54
55
56 to 5A
5B
5C to 67
68
69 to 6E
6F
70
71 to 9B
9C
9D
9E
9F
A0 to B1
B2
B3 to BC
BD
BE to FF
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Address
Remark
Initial value
Initial value
NTSC PAL
00 to FF
10
11 to 12
13
14
15
16
17
18
19
1A
1B
1C to 23
24
25
26
27
28
29
2A
2B
2C
2D
2E
2F
30
31
32
33
34
35
36
37
38
39
3A to 3D
3E
3F
40
41
42 to 44
45
46
47
48
49
4A
4B
40
39
80
88
47
81
88
CC
77
93
00
00
00
00
00
00
00
00
00
18
06
08
C7
0F
5D
10
76
41
2D
2D
64
02
DE
4E
BE
4D
69
40
39
80
88
47
81
88
C3
75
93
00
00
00
00
00
00
00
00
00
18
06
08
C7
0F
5D
10
76
41
2D
2D
64
02
DE
4E
BE
4D
69
54MHz/67.5MHz origin osc. adj.
Fixed data-1
HALL adj.
MAX GAIN adj.
LV standard data input
Fixed data-1
CCD output 2ch matching adjustment
(1)
Fixed data-1
CCD output 2ch matching adjustment
(2)
AWB standard data input
Auto white balance adj.
Fixed data-1
Color reproduction adj.
Fixed data-1
Color reproduction adj.
Fixed data-1
Strobe white balance adjustment
Color reproduction adj.
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Flange back adj.
6-20
DCR-TRV75/TRV75E/TRV80/TRV80E
Table. 6-1-11.
5. 1E Page Table
Note1:
When reading or writing the 1E page data, select page: 0, address:
10, and set data: 01, then select E page. The 1E page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to “00”.
Note2:
Fixed data-1: Initialized data. (Refer to “1. Initializing the E, F,
1E, 1F Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of E, F,
1E, 1F Page Data”).
Address
Remark
Initial value
Initial value
NTSC PAL
F Page
4C
4D
4E
4F
50
51
52
53
54
55
56
57
58
59
5A
5B
5C
5D
5E
5F
60
61
62
63
64
65
66
67
68
69
6A
6B
6C
6D to 71
72
73
74 to 75
76
77
78
79
7A
7B
7C
7D
7E
7F
80
81
82
83
84
85
86
Address
Remark
Initial value
Initial value
NTSC PAL
87
88
89
8A
8B
8C
8D
8E
8F
90
91
92
93 to B0
B1
B2 to F8
F9
FA to FF
1E
54
00
00
00
00
6E
19
19
32
00
06
00
80
80
80
80
40
C0
40
C0
40
C0
40
C0
20
00
00
00
00
00
00
40
00
34
00
30
00
2A
00
20
00
40
3A
31
31
35
1E
80
80
80
80
80
80
01
E0
80
80
80
20
19
1E
54
00
00
00
00
6E
19
19
32
00
06
00
80
80
80
80
40
C0
40
C0
40
C0
40
C0
20
00
00
00
00
00
00
40
00
34
00
30
00
2A
00
1E
00
40
3A
31
31
35
1E
80
80
80
80
80
80
01
E0
80
80
80
20
19
Flange back adj.
Fixed data-1
MR adj.
HALL adj.
Fixed data-1
Fixed data-2
Fixed data-1
Mechanical shutter adj.
Mechanical shutter adj.
Strobe light level adjustment
Hall adj.
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Table. 6-1-12.
6. 1F Page Table
Note1:
When reading or writing the 1F page data, select page: 0, address:
10, and set data: 01, then select F page. The 1F page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to “00”.
Note2:
Fixed data-1: Initialized data. (Refer to “1. Initializing the E, F,
1E, 1F Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of E, F,
1E, 1F Page Data”).
Address
Remark
00 to C8
C9
CA
CB
CC
CD
CE
CF
D0
D1
D2 to FF
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Address
Remark
00 to F2
F3
F4 to FF
Fixed data-1
Fixed data-2
Fixed data-1
Table. 6-1-13.
6-21
DCR-TRV75/TRV75E/TRV80/TRV80E
1-3.
CAMERA SYSTEM ADJUSTMENTS
Before perform the camera system adjustments (except for “54MHz/
67.5MHz Origin Oscillation Adjustment”), check that the specified
values of “VIDEO SYSTEM ADJUSTMENTS” are satisfied.
And check that the data of page: 0, address: 10 is “00”. If not, set
data: 00 to this address.
1. 54MHz/67.5MHz Origin Oscillation Adjustment
(CD-437 board)
Set the frequency of the clock for synchronization.
If deviated, the synchronization will be disrupted and the color will
become inconsistent.
Subject
Not required
Measurement Point
Pin <zc.> of IC2101 on VC-316 board
(R2132)
Measuring Instrument
Frequency counter
Adjustment Page
F
Adjustment Address
10
Specified Value
f=13500000 ± 68Hz
Note:
The data of page: 0, address: 10 must be “00”.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
F
10
Change the data and set the
frequency (f) to the specified
value.
3
F
10
Press PAUSE button.
4
0
01
00
Set the data.
2. HALL Adjustment
For detecting the position of the lens iris and ND filter, adjust AMP
gain and offset.
Subject
Not required
Measurement Point
Display data of page 1 (Note1)
Measuring Instrument
Adjustment remote commander
Adjustment Page
F
Adjustment Address
13 to 18, 92
Specified Value 1
D6 to DA
Specified Value 2
26 to 2A
Specified Value 3
D3 to DD
Specified Value 4
23 to 2D
Note1:
Displayed data of page 1 of the adjustment remote commander.
1 : XX : XX
IRIS display data
ND display data
Note2:
The data of page: 0, address: 10 must be “00”.
Switch setting:
POWER ......................................................................... CAMERA
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
6
01
6D
Set the data, and press PAUSE
button.
3
6
02
Check that the data changes to
“01”. (Note3)
4
6
01
00
Set the data, and press PAUSE
button.
Note3:
The adjustment data will be automatically input to page: F, address:
13 to 18, 92.
Checking method:
Order Page Address Data
Procedure
1
0
03
03
Set the data.
2
6
01
01
Set the data, and press PAUSE
button.
3
6
01
03
Set the data, and press PAUSE
button.
4
1
Check that the IRIS display data
(Note1) satisfies the specified value 1.
5
6
01
01
Set the data, and press PAUSE
button.
6
1
Check that the IRIS display data
(Note1) satisfies the specified value.2.
7
6
01
6B
Set the data, and press PAUSE
button.
8
6
01
69
Set the data, and press PAUSE
button.
9
1
Check that the ND display data
(Note1) satisfies the specified value 3.
10
6
01
6B
Set the data, and press PAUSE
button.
11
1
Check that the ND display data
(Note1) satisfies the specified value 4.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
6
01
00
Set the data, and press PAUSE
button.
2
0
03
00
Set the data.
3
0
01
00
Set the data.
Fig. 6-1-9.
COVER
COVER
IC2101
R2132
VC-316 board