DOWNLOAD Sony DCR-TRV738E / DCR-TRV740 / DCR-TRV740E / DCR-TRV840 Service Manual ↓ Size: 18.05 MB | Pages: 127 in PDF or view online for FREE

Model
DCR-TRV738E DCR-TRV740 DCR-TRV740E DCR-TRV840
Pages
127
Size
18.05 MB
Type
PDF
Document
Service Manual
Brand
Device
Movie / LEVEL 3
File
dcr-trv738e-dcr-trv740-dcr-trv740e-dcr-trv840.pdf
Date

Sony DCR-TRV738E / DCR-TRV740 / DCR-TRV740E / DCR-TRV840 Service Manual ▷ View online

5-16
DCR-TRV738E/TRV740/TRV740E/TRV840
1-2-4.
INITIALIZATION OF E, F, 1E, 1F PAGE DATA
Note:
When reading or writing the E, F page data, select page: 0, address:
10, and set data: 00.
When reading or writing the 1E or 1F page data, select page: 0,
address: 10, and set data: 01, then select E or F page. The 1E or 1F
page can be chosen by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
1. Initializing the E, F, 1E, 1F Page Data
Note1: If “Initializing the E, F, 1E, 1F Page Data” is performed,
all data of the E page, F page, 1E page and 1F page will
be initialized. (It is impossible to initialize a single page.)
Note2:
If the E, F, 1E, 1F page data has been initialized, following
adjustments need to be performed again.
1) Modification of E, F, 1E, 1F page data
2) 54MHz/66MHz origin osc. Adj.
3) Camera system adjustments
Note3:
The power supply voltage must be 6.0 ± 0.1Vdc.
Note4:
NTSC model: DCR-TRV840
PAL model: DCR-TRV738E/TRV740E
Adjusting page
E
Adjusting Address
00 to FF
Adjusting page
F
Adjusting Address
10 to FF
Adjusting page
1E
Adjusting Address
00 to 2F
Adjusting page
1F
Adjusting Address
00 to FF
Initializing Method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
0
10
00
Set the data.
3
6
01
Set the following data, and press
PAUSE button.
2D (NTSC), 2F (PAL)
4
6
03
01
Set the data, and press PAUSE
button.
5
6
02
Check that the data changes to
“01”.
6
2
00
29
Set the data
7
2
01
29
Set the data, and press the PAUSE
button.
8
Perform “Modification of E, F, 1E,
1F Page Data”.
2. Modification of E, F, 1E, 1F Page Data
If the E, F, 1E, 1F page data has been initialized, change the data of
the “Fixed data-2” address shown in the following table by manual
input.
Modifying Method:
1)
Before changing the data, select page: 0, address: 01, and set
data: 01.
2)
When changing the E, F page data, select page: 0, address: 10,
and set data: 00.
3)
When changing the 1E, 1F page data, select page: 0, address:
10, and set data: 01.
After completing the modification of 1E, 1F page data, reset
the data of this address to “00”.
4)
New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note:
If copy the data built in the different model, the camcorder may
not operate.
5)
When changing the data, press the PAUSE button of the
adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
6)
Check that the data of adjustment addresses is the initial value.
If not, change the data to the initial value.
Processing after Completing Modification of E, F, 1E, 1F Page
data
Order Page Address Data
Procedure
1
0
10
00
Set the data.
2
2
00
29
Set the data.
3
2
01
29
Set the data, and press PAUSE
button.
5-17
DCR-TRV738E/TRV740/TRV740E/TRV840
3. E Page Table
Note1: The data of page: 0, address: 10 must be “00”.
Note2: Fixed data-1: Initialized data. (Refer to “1. Initializing the E, F,
1E, 1F Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of E, F,
1E, 1F Page Data”.)
Table. 5-1-9.
6F
70
71
72 to 9B
9C
9D
9E
9F to CD
CE
CF to DF
E0
E1
E2
E3
E4
E5
E6
E7
E8
E9
EA
EB to EE
EF
F0 to F6
F7
F8 to FF
Fixed data-2
(Modified data. Copy the data built in the same
model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in the same
model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Address
Remark
00 to 04
05
06 to 07
08
09
0A
0B
0C to 0C
0D
0E
0F to 1A
1B
1C to 1F
20
21
22
23
24
25
26
27
28 to 3B
3C
3D
3E
3F
40 to 41
42
43 to 46
47
48 to 53
54
55
56 to 5A
5B
5C
5D
5E
5F
60
61
62
63
64 to 65
66
67
68
69
6A to 6E
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in the same
model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in the same
model.)
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in the same
model.)
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in the same
model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in the same
model.)
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in the same
model.)
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in the same
model.)
Fixed data-1
Address
Remark
5-18
DCR-TRV738E/TRV740/TRV740E/TRV840
4. F Page Table
Note1: The data of page: 0, address: 10 must be “00”.
Note2: Fixed data-1: Initialized data. (Refer to “1. Initializing the E, F,
1E, 1F Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of E, F,
1E, 1F Page Data”.)
Table. 5-1-10.
00 to FF
10
11 to 12
13
14
15
16 to 18
19
1A
1B
1C to 2F
30
31
32
33
34
35
36
37
38
39
3A to 3F
40
41
42 to 43
44
45
46
47
48
49
4A
4B
4C
4D
4E
4F
50
51
52
53
54
55
56
57
58
59 to 71
72
73
74 to 75
76
77
78
79
7A
7B
7C
7D
7E
7F
80
81
82
83
84
85
86
87
88
89
8A
8B
8C
8D
8E
8F
90 to 97
98
99
9A
9B
9C to A8
A9
AA
AB
AC to CF
D0
D1 to D7
D8
D9
DA
DB
DC
DD
DE
DF
E0 to E2
E3
E4
E5 to F6
E7
E8 to F4
F5
F6
F7
F8
F9
FA
FB
FC to FD
FE
FF
40
44
CE
17
80
7A
4D
3E
64
59
98
75
3A
2E
FE
DF
28
8E
34
69
11
64
00
00
00
00
2B
19
00
2F
00
00
00
40
00
34
00
30
00
2A
00
28
00
40
3A
31
31
35
1E
80
80
80
80
80
80
03
80
80
80
54/66MHz origin osc. adj.
Fixed data-1
HALL adj.
Fixed data-1
Fixed data-2
AWB & LV standard data input
Fixed data-1
AWB & LV standard data input
Auto white balance adj.
Fixed data-1
Color reproduction adj.
Fixed data-1
Color reproduction adj.
Fixed data-1
Color reproduction adj.
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in
the same model.)
Flange back adj.
Fixed data-1
Fixed data-2
Fixed data-1
Mechanical shutter adj.
Mechanical shutter adj.
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in
the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in
the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Address
Remark
Initial value
Address
Remark
Initial value
5-19
DCR-TRV738E/TRV740/TRV740E/TRV840
5. 1E Page Table
Note1:
When reading or writing the 1E page data, select page: 0, address:
10, and set data: 01, then select E page. The 1E page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
Note2:
Fixed data-1: Initialized data. (Refer to “1. Initializing the E, F,
1E, 1F Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of E, F,
1E, 1F Page Data”.)
Table. 5-1-11.
6. 1F Page Table
Note1:
When reading or writing the 1F page data, select page: 0, address:
10, and set data: 01, then select F page. The 1F page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
Note2:
Fixed data-1: Initialized data. (Refer to “1. Initializing the E, F,
1E, 1F Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of E, F,
1E, 1F Page Data”.)
Table. 5-1-12.
00 to 1F
20
21
22
23
24
25
26
27
28
29
2A
2B
2C
2D
2E
2F
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
Fixed data-1
Black defective CCD adj.
Address
Remark
Initial value
00 to 38
39
3A to 41
42
43 to 44
45
46
47 to 9F
A0
A1
A2
A3 to AB
AC
AD
AE
AF
B0 to B1
B2
B3
B4
B5 to B7
B8
B9
BA
BB to BD
BE
BF to C9
CA
CB
CC
CD to CE
CF
D0 to DC
DD
DE to E4
E5
E6 to FF
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in the same
model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in the same
model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Address
Remark
Page of 127
Display

Click on the first or last page to see other DCR-TRV738E / DCR-TRV740 / DCR-TRV740E / DCR-TRV840 service manuals if exist.