DOWNLOAD Sony DCR-TRV380 / DCR-TRV480 / DCR-TRV480E (serv.man4) Service Manual ↓ Size: 1.38 MB | Pages: 64 in PDF or view online for FREE

Model
DCR-TRV380 DCR-TRV480 DCR-TRV480E (serv.man4)
Pages
64
Size
1.38 MB
Type
PDF
Document
Service Manual
Brand
Device
Movie / SECTION 6 ADJUSTMENTS
File
dcr-trv380-dcr-trv480-dcr-trv480e-sm4.pdf
Date

Sony DCR-TRV380 / DCR-TRV480 / DCR-TRV480E (serv.man4) Service Manual ▷ View online

6-46
DCR-TRV380/TRV480/TRV480E
3-4.
VIDEO SYSTEM ADJUSTMENTS
Before performing the video system adjustments, check that the
data of page: 0, address: 10 is “00”.
If not, select  page: 0, address: 10, and set data “00”.
Video system adjustments must be performed in the following or-
der.
Adjusting Procedure:
1. 27 MHz origin oscillation adjustment
2. Composite video out level adjustment
3. Hi8/Standard8 Y/C output level setting (Note)
4. Hi8/Standard8 AFC f
0
 adjustment (Note)
Note:
DCR-TRV480/TRV480E only
1. 27 MHz Origin Oscillation Adjustment
(VC-345 Board)
Set the frequency of the clock for synchronization.
If deviated, the synchronization will be disrupted and the color
will become inconsistent.
Mode
CAMERA
Subject
Arbitrary
Measurement Point
Pin <z.,  of IC2201
Measuring Instrument
Frequency counter
Adjustment Page
F
Adjustment Address
10
Specified value
f = 13500000 
± 68 Hz
Note:
Check that the data of page: 0, address: 10 is “00”.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
F
10
Change the data and set the
frequency (f) to the specified
value.
3
F
10
Press PAUSE button.
4
0
01
00
Fig. 6-3-5
IC2201
54
55
108
109
162
163
216
1
198
Measurement
Point
VC-345 BOARD (SIDE A)
6-47
DCR-TRV380/TRV480/TRV480E
2.
Composite Video Out Level Adjustment
(VC-345 Board)
Mode
CAMERA
Subject
Arbitrary
Measurement Point
Video terminal of A/V jack
(75 
Ω terminated)
Measuring Instrument
Oscilloscope
Adjustment Page
C
Adjustment Address
25, 26, 27
Specified value
Sync level:
A = 1 V 
± 20 mVp-p (NTSC)
A = 1 V 
± 20 mVp-p (PAL)
Cr level:
B = 714 
± 14 mVp-p (NTSC)
B = 700 
± 14 mVp-p (PAL)
Cr level:
C = 714 
± 14 mVp-p (NTSC)
C = 700 
± 14 mVp-p (PAL)
Burst level:
D = 286 
± 6 mVp-p (NTSC)
D = 300 
± 6 mVp-p (PAL)
Note 1:
Check that the data of page: 0, address: 10 is “00”.
Note 2:
NTSC model: DCR-TRV380/TRV480
PAL model: DCR-TRV480E
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
8
A0
Set the bit value of bit 3 to “1”,
and press PAUSE button.
(Note 3)
3
3
0C
02
Press PAUSE button.
4
C
25
Change the data and set the Y
signal level (A) to the
specified value.
5
C
25
Press PAUSE button.
6
C
26
Change the data and set the
Cr signal level (B) to the
specified value.
7
C
26
Press PAUSE button.
8
C
27
Change the data and set the
Cb signal level (C) to the
specified value.
9
C
27
Press PAUSE button.
10
Check the burst signal (D) to
the specified value.
11
8
A0
Set the bit value of bit 3 to “0”,
and press PAUSE button.
(Note 3)
12
3
0C
00
Press PAUSE button.
13
0
01
00
Note 3:
For the bit values, refer to  “6-4. SERVICE MODE”, “4-
3. 3. Bit Value Discrimination”.
Fig. 6-3-6
H
A
B
0.28 
µ
sec (NTSC)
0.23 
µ
sec (PAL)
0.28 
µ
sec (NTSC)
0.23 
µ
sec (PAL)
C
D
6-48
DCR-TRV380/TRV480/TRV480E
4.
Hi8/Standard8 AFC f
0
 Adjustment 
RadarW
RadarW
RadarW
RadarW
RadarW
(VC-345 Board) (DCR-TRV480/TRV480E)
Adjust the pull-in range of the clock generator (IC2201) for A/D
conversion during Hi8/Standard8 playback.
Mode
VTR stop (PLAY/EDIT mode)
Signal
No signal
Measurement Point
Displayed data of page: 3, address:
9D
Measuring Instrument
Adjusting remote commander
Adjustment Page
C
Adjustment Address
34
Specified value
The data of page: 3, address: 9D is
“7C” to ”84”.
Note 1:
Check that the data of page: 0, address: 10 is “00”.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
C
34
30
Press PAUSE button.
3
A
10
02
Press PAUSE button.
4
3
0D
04
Press PAUSE button.
5
3
93
04
6
3
9E
01
7
Wait for 1.5 second.
8
3
01
82
Press PAUSE button. (Note 3)
9
3
02
Check the data changes to
“00”.
10
3
03
Check the data is “00”.
11
3
9D
Check that the data satisfied
the specified value.
12
3
0D
00
Press PAUSE button.
13
3
93
00
14
3
9E
00
15
A
10
00
Press PAUSE button.
16
0
01
00
Note 2:
For the bit value, refer to “6-4. SERVICE MODE”, “4-3.
3. Bit Value Discrimination”.
Note 3:
The adjustment data will be automatically input to page:
C, address: 34.
3.
Hi8/Standard8 Y/C Output Level Setting 
RadarW
RadarW
RadarW
RadarW
RadarW
(VC-345 Board) (DCR-TRV480/TRV480E)
Set the Y/C signal output level during Hi8/Standard8 playback
mode.
Mode
VTR stop (PLAY/EDIT mode)
Signal
No signal
Adjustment Page
C
Adjustment Address
35, 36
Note 1:
Check that the data of page: 0, address: 10 is “00”.
Note 2:
Perform this adjustment when IC2201 or IC4502 is re-
placed.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
A
10
02
Press PAUSE button.
3
3
9E
01
4
3
A4
Check the data.
When the data is “53”, proceed
to step 5.
When the data is “03”, proceed
to step 8.
5
C
35
Set the following data and
press PAUSE button.
69: NTSC model
65: PAL model
6
C
36
Set the following data and
press PAUSE button.
64: NTSC model
72: PAL model
7
Proceed to step 10.
8
C
35
A0
Press PAUSE button.
9
C
36
Set the following data and
press PAUSE button.
AA: NTSC model
B8: PAL model
10
3
9E
00
11
A
10
00
Press PAUSE button.
12
0
01
00
6-49
DCR-TRV380/TRV480/TRV480E
1. Hi8/Standard8 AFM BPF f
0
 Adjustment
(VC-345 Board) (DCR-TRV480/TRV480E)
Sets the BPF passing frequency of IC5401 so that the AFM signal
can separate from the playback RF signal properly. If deviated.
the mono/stereo mode will be differentiated incorrectly, and noises
and distortions will increase during high volume playback.
Mode
Playback (PLAY/EDIT mode)
Signal
Hi8/Standard  alignment tape:
For BPF adjustment
(WR5-11NS (NTSC))
(WR5-11CS (PAL))
Measurement Point
Audio left or right terminal of A/V
jack
Measuring Instrument
Distortion meter
Adjustment Page
C
Adjustment Address
3A
Specified Value
The Main and Sub channel distortion
rate should be almost the same
(within 
± 1%) and minimum.
Note:
Check that the data of page: 0, address: 10 is “00”.
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Set the MULTI sound switch (menu display) to “2”.
3) Select page: C, address: 3A, change the data and minimize the
distortion rate.
4) Press the PAUSE button of the adjustment remote commander.
5) Set the MULTI sound switch (menu display) to “1”.
6) Select page: C, address: 3A, change the data and minimize the
distortion rate.
7) Press the PAUSE button of the adjustment remote commander.
8) Repeat steps 2) to 7) and set the data of address: 3A so that the
distortions rates when the MULTI sound switch is set to “2”
and set to “1” respectively are almost the same and minimum.
9) Press the PAUSE button of the adjustment remote commander.
10) Select page: 0, address: 01, and set data: 00.
11) Set the MULTI sound switch to “STEREO”.
3-5.
AUDIO SYSTEM ADJUSTMENTS
Before performing the audio system adjustments, check that the
data of page: 0, address: 10 is “00”.
If not, select  page: 0, address: 10, and set data “00”.
[Connecting the measuring instruments for the audio]
Connect the audio system measuring instruments in addition to
the video system measuring instruments as shown in Fig. 6-3-7.
[Adjustment Procedure]
1) Hi8/Standard8 AFM BPF f
0
 adjustment (Note)
2) Hi8/Standard8 AFM 1.5 MHz deviation adjustment (Note)
3) Hi8/Standard8 AFM 1.7 MHz deviation adjustment (Note)
4) Digital8 playback level check
Note:
DCR-TRV480/TRV480E only
Fig. 6-3-7
Main unit
47 k 
47 k 
: 1-249-437-11
Audio level meter or
distortion meter
TV monitor
A/V jack
Video
Audio (L)
Audio (R)
In Playback
Page of 64
Display

Click on the first or last page to see other DCR-TRV380 / DCR-TRV480 / DCR-TRV480E (serv.man4) service manuals if exist.