Sony DCR-TRV360 / DCR-TRV361 / DCR-TRV460 / DCR-TRV460E / DCR-TRV461E (serv.man4) Service Manual ▷ View online
DCR-TRV360/TRV361/TRV460/TRV460E/TRV461E
6-46
6.
Hi8/Standard8 Switching Position Adjustment
(VC-345 Board) (DCR-TRV460/TRV460E/TRV461E)
(VC-345 Board) (DCR-TRV460/TRV460E/TRV461E)
If deviated in this case cause switching noise or jitter on the Hi8/
Standard8 mode played back screen.
Standard8 mode played back screen.
Mode
VTR playback (PLAY/EDIT mode)
Signal
Hi8/Standard8 alignment tape:
For tracking adjustment
(WR5-1NP (NTSC))
(WR5-1CP (PAL))
For tracking adjustment
(WR5-1NP (NTSC))
(WR5-1CP (PAL))
Measurement Point
CH1: SWP (Pin 5 of CN1011)
CH2: IR VIDEO (Pin 2 of CN1011)
CH2: IR VIDEO (Pin 2 of CN1011)
Measuring Instrument
Oscilloscope
Adjustment Page
C
Adjustment Address
32, 33
Specified value
t1 = 0
±
10
µ
sec
Note 1:
Check that the data of page: 0, address: 10 is “00”.
Adjusting method:
Order Page Address Data
Procedure
1
Insert the alignment tape and
enter the VTR stop mode.
enter the VTR stop mode.
2
0
01
01
3
3
92
Set the bit value of bit2 to “1”,
and press PAUSE button.
(Note 2)
and press PAUSE button.
(Note 2)
4
Set to the playback mode.
5
C
32
Change the data and minimize
“t1”. (Coarse adjustment)
“t1”. (Coarse adjustment)
6
C
32
Press PAUSE button.
7
C
33
Change the data and adjust so
that the switching position (t1)
becomes specified value. (Fine
adjustment)
that the switching position (t1)
becomes specified value. (Fine
adjustment)
8
C
33
Press PAUSE button.
9
3
92
Set the bit value of bit2 to “0”,
and press PAUSE button.
(Note 2)
and press PAUSE button.
(Note 2)
10
0
01
00
Note 2:
For the bit value, refer to “6-4. SERVICE MODE”, “4-3.
3. Bit Value Discrimination”.
3. Bit Value Discrimination”.
Fig. 6-3-4
CH1
CH2
Enlargement
t1=0
±
10
µ
sec
CH1
CH2
DCR-TRV360/TRV361/TRV460/TRV460E/TRV461E
6-47
3-4.
VIDEO SYSTEM ADJUSTMENTS
Before performing the video system adjustments, check that the
data of page: 0, address: 10 is “00”.
If not, select page: 0, address: 10, and set data “00”.
Video system adjustments must be performed in the following or-
der.
data of page: 0, address: 10 is “00”.
If not, select page: 0, address: 10, and set data “00”.
Video system adjustments must be performed in the following or-
der.
Adjusting Procedure:
1. 27 MHz origin oscillation adjustment
2. S VIDEO OUT Y level adjustment
3. S VIDEO OUT C level adjustment
4. VIDEO OUT level check
5. Hi8/Standard8 Y/C output level setting (Note)
6. Hi8/Standard8 AFC f
1. 27 MHz origin oscillation adjustment
2. S VIDEO OUT Y level adjustment
3. S VIDEO OUT C level adjustment
4. VIDEO OUT level check
5. Hi8/Standard8 Y/C output level setting (Note)
6. Hi8/Standard8 AFC f
0
adjustment (Note)
Note:
DCR-TRV360/TRV361/TRV460/TRV460E/TRV461E only
1. 27 MHz Origin Oscillation Adjustment
(VC-345 Board)
Set the frequency of the clock for synchronization.
If deviated, the synchronization will be disrupted and the color
will become inconsistent.
If deviated, the synchronization will be disrupted and the color
will become inconsistent.
Mode
CAMERA
Subject
Arbitrary
Measurement Point
Pin <z., of IC2201
Measuring Instrument
Frequency counter
Adjustment Page
F
Adjustment Address
10
Specified value
f = 13500000
± 68 Hz
Note:
Check that the data of page: 0, address: 10 is “00”.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
F
10
Change the data and set the
frequency (f) to the specified
value.
frequency (f) to the specified
value.
3
F
10
Press PAUSE button.
4
0
01
00
Fig. 6-3-5
2.
S VIDEO OUT Y Level Adjustment (VC-345 Board)
Mode
CAMERA
Subject
Arbitrary
Measurement Point
Y signal terminal of
S VIDEO jack (75
S VIDEO jack (75
Ω terminated)
Measuring Instrument
Oscilloscope
Adjustment Page
C
Adjustment Address
25
Specified value
A = 1000
± 20 mVp-p
Note 1:
Check that the data of page: 0, address: 10 is “00”.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
8
A0
Set the bit value of bit 3 to “1”,
and press PAUSE button.
(Note 2)
and press PAUSE button.
(Note 2)
3
3
0C
02
Press PAUSE button.
4
C
25
Change the data and set the Y
signal level (A) to the
specified value.
signal level (A) to the
specified value.
5
C
25
Press PAUSE button.
6
8
A0
Set the bit value of bit 3 to “0”,
and press PAUSE button.
(Note 2)
and press PAUSE button.
(Note 2)
7
3
0C
00
Press PAUSE button.
8
0
01
00
Note 2:
For the bit values, refer to “6-4. SERVICE MODE”, “4-
3. 3. Bit Value Discrimination”.
3. 3. Bit Value Discrimination”.
H
Center of luminance line
A
Fig. 6-3-6
IC2201
54
55
108
109
162
163
216
1
198
Measurement
Point
Point
VC-345 BOARD (SIDE A)
DCR-TRV360/TRV361/TRV460/TRV460E/TRV461E
6-48
3.
S VIDEO OUT C Level Adjustment (VC-345 Board)
Mode
CAMERA
Subject
Arbitrary
Measurement Point
Chroma signal terminal of
S VIDEO jack (75
S VIDEO jack (75
Ω terminated)
External trigger: Y signal terminal of
S VIDEO jack (75
S VIDEO jack (75
Ω terminated)
Measuring Instrument
Oscilloscope
Adjustment Page
C
Adjustment Address
26, 27
Specified value
Cr level: A = 714
± 14 mVp-p (NTSC)
A = 700
± 14 mVp-p (PAL)
Cb level:B = 714
± 14 mVp-p (NTSC)
B = 700
± 14 mVp-p (PAL)
Burst level: C = 286
± 6 mVp-p (NTSC)
C = 300
± 6 mVp-p (PAL)
Note 1:
Check that the data of page: 0, address: 10 is “00”.
Note 2:
NTSC model: DCR-TRV360/TRV361/TRV460
PAL model: DCR-TRV460E/TRV461E
PAL model: DCR-TRV460E/TRV461E
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
8
A0
Set the bit value of bit 3 to “1”,
and press PAUSE button.
(Note 3)
and press PAUSE button.
(Note 3)
3
3
0C
02
Press PAUSE button.
4
C
26
Change the data and set the
Cr signal level (A) to the
specified value.
Cr signal level (A) to the
specified value.
5
C
26
Press PAUSE button.
6
C
27
Change the data and set the
Cb signal level (B) to the
specified value.
Cb signal level (B) to the
specified value.
7
C
27
Press PAUSE button.
8
Check the burst signal (C) to
the specified value.
the specified value.
9
8
A0
Set the bit value of bit 3 to “0”,
and press PAUSE button.
(Note 3)
and press PAUSE button.
(Note 3)
10
3
0C
00
Press PAUSE button.
11
0
01
00
Note 3:
For the bit values, refer to “6-4. SERVICE MODE”, “4-
3. 3. Bit Value Discrimination”.
3. 3. Bit Value Discrimination”.
Fig. 6-3-7
H
C
A
0.28
µ
sec (NTSC)
0.23
µ
sec (PAL)
B
0.28
µ
sec (NTSC)
0.23
µ
sec (PAL)
DCR-TRV360/TRV361/TRV460/TRV460E/TRV461E
6-49
4. VIDEO OUT Level Check (VC-345 Board)
Mode
CAMERA
Subject
Arbitrary
Measurement Point
Video terminal of A/V jack
(75
(75
Ω terminated)
Measuring Instrument
Oscilloscope
Specified value
Sync level:
A = 286
± 18 mVp-p (NTSC)
A = 300
± 18 mVp-p (PAL)
Burst level:
B = 286
± 18 mVp-p (NTSC)
B = 300
± 18 mVp-p (PAL)
Note:
NTSC model: DCR-TRV360/TRV361/TRV460
PAL model: DCR-TRV460E/TRV461E
PAL model: DCR-TRV460E/TRV461E
Checking method:
Order Page Address Data
Procedure
1
Check that the SYNC level
(A) satisfies the specified
value.
(A) satisfies the specified
value.
2
Check that the burst level (B)
satisfies the specified value.
satisfies the specified value.
Fig. 6-3-8
H
B
A
5.
Hi8/Standard8 Y/C Output Level Setting
RadarW
RadarW
RadarW
(VC-345 Board) (DCR-TRV460/TRV460E/TRV461E)
Set the Y/C signal output level during Hi8/Standard8 playback
mode.
mode.
Mode
VTR stop (PLAY/EDIT mode)
Signal
No signal
Adjustment Page
C
Adjustment Address
35, 36
Note 1:
Check that the data of page: 0, address: 10 is “00”.
Note 2:
Perform this adjustment when IC2201 or IC4502 is re-
placed.
placed.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
A
10
02
Press PAUSE button.
3
3
9E
01
4
3
A4
Check the data.
When the data is “53”, proceed
to step 5.
When the data is “03”, proceed
to step 8.
When the data is “53”, proceed
to step 5.
When the data is “03”, proceed
to step 8.
5
C
35
Set the following data and
press PAUSE button.
69: NTSC model
65: PAL model
press PAUSE button.
69: NTSC model
65: PAL model
6
C
36
Set the following data and
press PAUSE button.
64: NTSC model
72: PAL model
press PAUSE button.
64: NTSC model
72: PAL model
7
Proceed to step 10.
8
C
35
A0
Press PAUSE button.
9
C
36
Set the following data and
press PAUSE button.
AA: NTSC model
B8: PAL model
press PAUSE button.
AA: NTSC model
B8: PAL model
10
3
9E
00
11
A
10
00
Press PAUSE button.
12
0
01
00
Click on the first or last page to see other DCR-TRV360 / DCR-TRV361 / DCR-TRV460 / DCR-TRV460E / DCR-TRV461E (serv.man4) service manuals if exist.