Sony DCR-TRV25 / DCR-TRV27 Service Manual ▷ View online

5-11
DCR-TRV25/TRV27
1-2-2.
INITIALIZATION OF B, 1B PAGE DATA
Note:
When reading or writing the B page data, select page: 0, address:
10, and set data: 00.
When reading or writing the 1B page data, select page: 0, address:
10, and set data: 01, then select B page. The 1B page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
1. Initializing the B, 1B Page Data
Note1: If “Initializing the B, 1B Page Data” is performed, all data
of the B page and 1B page will be initialized. (It is
impossible to initialize a single page.)
Note2:
If the B, 1B page data has been initialized, the following
adjustments need to be performed again.
1) Modification of B, 1B page data
Note3:
The power supply voltage must be 6.0 ± 0.1Vdc.
Adjusting page
B
Adjusting Address
00 to FF
Adjusting page
1B
Adjusting Address
00 to FF
Initializing Method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
0
10
00
Set the data.
3
5
02
FF
Set the data.
4
5
01
F3
Set the data, and press PAUSE
button.
5
5
00
01
Set the data, and press PAUSE
button.
6
5
02
Check that the data changes to “00”.
7
Perform “Modification of B, 1B
Page Data”.
2. Modification of B, 1B Page Data
If the B, 1B page data has been initialized, change the data of the
“Fixed data-2” address shown in the following tables by manual
input.
Modifying Method:
1)
Before changing the data, select page: 0, address: 01, and set
data: 01.
2)
When changing the B page data, select page: 0, address: 10,
and set data: 00.
3)
When changing the 1B page data, select page: 0, address: 10,
and set data: 01.
After completing the modification of 1B page data, reset the
data of this address to “00”.
4)
New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note:
If copy the data built in the different model, the camcorder may
not operate.
5)
When changing the data, press the PAUSE button of the
adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
Processing after Completing Modification of B, 1B Page data:
Order Page Address Data
Procedure
1
0
10
00
Set the data.
2
2
00
29
Set the data.
3
2
01
29
Set the data, and press PAUSE
button.
3. B Page Table
Note1:
The data of page: 0, address: 10 must be “00”.
Note2:
Fixed data-1: Initialized data. (Refer to “1. Initializing the B, 1B
Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of B, 1B
Page Data”).
Table. 5-1-4.
4. 1B Page Table
Note1:
When reading or writing the 1B page data, select page: 0, address:
10, and set data: 01, then select B page. The 1B page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
Note2:
Fixed data-1: Initialized data. (Refer to “1. Initializing the B, 1B
Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of B, 1B
Page Data”).
Table. 5-1-5.
Address
00 to FF
Remark
Fixed data-1
Address
00 to FF
Remark
Fixed data-1
5-12
DCR-TRV25/TRV27
1-2-3.
INITIALIZATION OF 8, C PAGE DATA
Note:
The data of page: 0, address: 10 must be “00”.
1. Initializing the 8, C Page Data
Note1: If “Initializing the 8, C Page Data” is performed, all data
of the 8 page and C page will be initialized. (It is
impossible to initialize a single page.)
Note2:
If the 8, C page data has been initialized, following adjustments
need to be performed again.
1) Modification of 8, C page data
2) Serial No. input
3) Viewfinder system adjustments
4) LCD system adjustments
5) Servo and RF system adjustments
6) Video system adjustments
Note3:
The power supply voltage must be 6.0 ± 0.1Vdc.
Adjusting page
8
Adjusting Address
00 to A3
Adjusting page
C
Adjusting Address
10 to FF
Initializing Method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
0
10
00
Set the data.
3
3
81
Check that the data is “00”.
4
3
80
0C
Set the data, and press PAUSE
button.
5
3
80
Check that the data changes to “1C”.
6
Perform “Modification of 8, C
Page Data”.
2. Modification of 8, C Page Data
If the 8, C page data has been initialized, change the data of the
“Fixed data-2” address shown in the following table by manual input.
Modifying Method:
1)
Before changing the data, select page: 0, address: 01, and set
data: 01.
2)
New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note:
If copy the data built in the different model, the camcorder may
not operate.
3)
When changing the data, press the PAUSE button of the
adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
4)
Check that the data of adjustment addresses is the initial value.
If not, change the data to the initial value.
Processing after Completing Modification of 8, C Page data
Order Page Address Data
Procedure
1
2
00
29
Set the data.
2
2
01
29
Set the data, and press PAUSE
button.
3. 8 Page Table
Note1:
The data of page: 0, address: 10 must be “00”.
Note2:
Fixed data-1: Initialized data. (Refer to “1. Initializing the 8, C
Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of 8, C
Page Data”).
Table. 5-1-6.
00 to 18
19
1A to 28
29
2A to 2E
2F
30 to 3A
3B
3C to 49
4A
4B to 59
5A
5B to 79
7A
7B
7C
7D
7E
7F
80
81
82
83 to 89
8A
8B
8C
8D
8E
8F
90
91
92
93
94 to A3
08
00
46
01
02
00
00
00
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Serial No. input
Fixed data-1
Address
Remark
Initial value
5-13
DCR-TRV25/TRV27
4. C Page Table
Note1:
The data of page: 0, address: 10 must be “00”.
Note2:
Fixed data-1: Initialized data. (Refer to “1. Initializing the 8, C
Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of 8, C
Page Data”).
00 to 0F
10
11
12
13
14 to 15
16
17
18
19
1A
1B
1C
1D
1E
1F
20
21
22
23 to 24
25
26
27
28
29
2A to 2B
2C
2D to 4E
4F
50
51
52
53
54
55
56
57
58
59 to 5E
5F
60
61
62
63
64
65
66
67
68
69
6A
EE
00
00
00
E0
2A
2A
32
32
25
3E
3E
DC
99
88
E3
A1
04
20
03
87
6F
97
80
80
37
80
70
80
30
C0
80
80
50
Switching position adj.
Fixed data-1
CAP FG duty adj.
Fixed data-1
AEQ adj.
Fixed data-1
AEQ adj.
Fixed data-1
AGC center level adj.
PLL fo adj.
APC adj.
LPF fo adj.
Fixed data-1
S VIDEO out Y level adj.
S VIDEO out Cr level adj.
S VIDEO out Cb level adj.
Chroma BPF fo adj.
PLL fo adj.
Fixed data-1
APC adj.
Fixed data-1
Fixed data-2
VCO adj. (EVF)
Fixed data-2
RGB AMP adj. (EVF)
Fixed data-1
White balance adj. (EVF)
Contrast adj. (EVF)
Fixed data-1
Fixed data-2
VCO adj. (LCD)
V COM adj. (LCD)
RGB AMP adj. (LCD)
Fixed data-1
COM AMP adj. (LCD)
White balance adj. (LCD)
Contrast adj. (LCD)
Fixed data-1
Address
Remark
Initial value
Address
Remark
Initial value
6B
6C
6D to 80
81
82
83 to 88
89
8A
8B
8C
8D to A9
AA
AB to AC
AD
AE
AF
B0 to C0
C1
C2
C3
C4
C5
C6
C7 to C8
C9
CA
CB
CC
CD
CE
CF to D0
D1
D2
D3
D4
D5
D6
D7
D8
D9
DA
DB
DC
DD
DE
DF
E0
E1
E2
E3
E4 to E7
E8
E9
EA
EB
EC
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
5-14
DCR-TRV25/TRV27
Table. 5-1-7.
Address
Remark
Initial value
ED
EE
EF
F0 to F1
F2
F3
F4
F5
F6
F7
F8
F9
FA
FB
FC
FD
FE
FF
00
00
00
00
00
00
00
00
00
00
00
00
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Emergency memory address
C Page
Page of 127
Display