DOWNLOAD Sony DCR-TRV240E / DCR-TRV340E (serv.man4) Service Manual ↓ Size: 11.64 MB | Pages: 127 in PDF or view online for FREE

Model
DCR-TRV240E DCR-TRV340E (serv.man4)
Pages
127
Size
11.64 MB
Type
PDF
Document
Service Manual
Brand
Device
Movie / LEVEL 2
File
dcr-trv240e-dcr-trv340e-sm4.pdf
Date

Sony DCR-TRV240E / DCR-TRV340E (serv.man4) Service Manual ▷ View online

5-7
DCR-TRV240E/TRV340E
H
A=B
C=D
A B
B
C
D
A
Enlargement
V
Electronic beam scanning frame
CRT picture frame
B
A
Difference in level
Y
ello
w
Cy
an
Green
White
Magenta
Red
Blue
Y
ello
w
Cy
an
Green
White
Magenta
Red
Blue
Color bar chart (Color reproduction adjustment frame)
Fig. a
(VIDEO terminal
output waveform)
Fig. b (monitor TV picture)
Adjust the camera zoom and direction to
obtain the output waveform shown in Fig. a
and the monitor TV display shown in Fig. b.
White
Black
841mm
1189mm
1-1-3.
Precaution
1. Setting the Switch
Unless otherwise specified, set the switches as follows and perform
adjustments without loading cassette.
1.
POWER switch (SS-1380 block) ........................... CAMERA
2.
NIGHT SHOT switch (Lens block) ................................. OFF
3.
COLOR SLOW SHUTTER (FK-2500 block) ................. OFF
4.
DEMO MODE (Menu display) ....................................... OFF
5.
DIGITAL ZOOM (Menu display) ................................... OFF
6.
STEADY SHOT (Menu display) ..................................... OFF
7.
DISPLAY (Menu display) ................................. V-OUT/LCD
8.
DISPLAY (CF-2500 block) .............................................. ON
9.
FOCUS switch (CF-2500 block) .......................... MANUAL
10. BACK LIGHT (CF-2500 block) ...................................... OFF
11. PROGRAM AE (Menu display) ...................................... OFF
12. PICTURE EFFECT (Menu display) ................................ OFF
13. DIGITAL EFFECT (Menu display) ................................. OFF
14. AUTO SHUTTER (Menu display) .................................. OFF
15. 16 : 9 WIDE (MENU display) ......................................... OFF
2. Order of Adjustments
Basically carry out adjustments in the order given.
Fig.5-1-4.
3. Subjects
1)
Color bar chart (Color reproduction adjustment frame)
When performing adjustments using the color bar chart, adjust
the picture frame as shown in Fig. 5-1-4. (Color reproduction
adjustment frame)
2)
Clear chart (Color reproduction adjustment frame)
Remove the color bar chart from the pattern box and insert a
clear chart in its place. (Do not perform zoom operations during
this time.)
3)
Flange back adjustment chart
Make the chart shown in Fig. 5-1-5 using A0 size (1189mm 
×
841mm) black and white vellum paper.
Fig. 5-1-5.
Note:
Use matte vellum paper bigger than A0, and make sure the edges of
the black and white paper joined together are not rough.
5-8
DCR-TRV240E/TRV340E
1-2.
INITIALIZATION OF 8, A, B, C, D, E, F, 1B, 1C,
1F PAGE DATA
Note1:
When reading or writing the 1B, 1C, 1F page data, select page: 0,
address: 10, and set data: 01, then select B, C or F page. The 1B.
1C or 1F page can be chosen by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
Note2:
The A, B and 1B page are DCR-TRV340E model only.
[Connection of the power supply during the initialization
of the data.]
1)
Connect the regulated power supply and the digital voltmeter
to the battery terminal as shown in Fig. 5-1-6.
2)
Adjust the output voltage of the regulated power supply so that
the digital voltmeter display is 6.0 ± 0.1Vdc.
3)
Turn off the power supply.
4)
Turn on the HOLD switch of the adjusting remote commander.
5)
Turn on the power supply.
6)
Perform the initialization of the data.
Note3:
This is normal though the following message is indicated on the
LCD screen.
“FOR InfoLITHIUM BATTERY ONLY”
[Initialization Procedure]
DCR-TRV240E:
1.
Initialization of D page data
2.
Initialization of 8, C, 1C page data
3.
Initialization of E, F, 1F page data
DCR-TRV340E:
1.
Initialization of A, D page data
2.
Initialization of B, 1B page data
3.
Initialization of 8, C, 1C page data
4.
Initialization of E, F, 1F page data
Digital voltmeter
Regulated power supply
Battery terminal
Fig. 5-1-6.
5-9
DCR-TRV240E/TRV340E
1-2-1.
INITIALIZATION OF D PAGE DATA
(DCR-TRV240E)
Note:
The data of page: 0, address: 10 must be “00”.
1. Initializing the D Page Data
Note1:
If the D page data has been initialized, the following adjustments
need to be performed again.
1) Modification of D page data
Note2:
The power supply voltage must be 6.0 ± 0.1Vdc.
Adjusting page
D
Adjusting Address
10 to FF
Initializing Method:
Order Page Address Data
Procedure
1
0
01
01
Set the data
2
0
10
00
Set the data
3
2
00
35
Set the data
4
2
01
35
Set the data, and press the PAUSE
button.
5
2
02
Check that the data changes to
“01”
6
2
00
29
Set the data
7
2
01
29
Set the data, and press the PAUSE
button.
8
Perform “Modification of D Page
Data”.
2. Modification of D Page Data
If the D page data has been initialized, change the data of the “Fixed
data-2” address shown in the following tables by manual input.
Modifying Method:
1)
Before changing the data, select page: 0, address: 01, and set
data: 01.
2)
New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note:
If copy the data built in the different model, the camcorder may
not operate.
3)
When changing the data, press the PAUSE button of the
adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
Processing after Completing Modification of D Page data
Order Page Address Data
Procedure
1
2
00
29
Set the data
2
2
01
29
Set the data, and press the PAUSE
button.
Note:
If the following symptoms occur after completing of the
“Modification of D page data”, check that the data of the “Fixed
data-2” addresses of D page are same as those of the same model of
the same destination.
1) The self-diagnosis code “E: 20:00” is displayed on the LCD
screen.
2) The power is shut off so that unit cannot operate.
3. D Page Table
Note1:
The data of page: 0, address: 10 must be “00”.
Note2:
Fixed data-1: Initialized data. (Refer to “1. Initializing the D Page
Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of D Page
Data”.)
00 to 0F
10
11
12
13
14
15 to 32
33
34 to 42
43
44
45
46
47
48
49
4A to 4C
4D
4E to 4F
50
51
52
53
54
55 to 57
58
59
5A
5B
5C
5D to 64
65
66
67
68
69 to 6B
6C
6D
6E
6F
70 to 77
78
79
7A
7B
7C
7D to 8D
8E
8F
90 to B6
B7
B8
B9
BA to CF
D0
D1
D2 to FF
00
00
00
Test mode
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Modified data. Copy the data built in
the same model.
Fixed data-1
Fixed data-2
Modified data. Copy the data built in
the same model.
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Modified data. Copy the data built in
the same model.
Fixed data-1
Fixed data-2
Modified data. Copy the data built in
the same model.
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Drum rotation counted time.
(Refer to “5-4. SERVICE MODE.”)
Fixed data-1
Address
Remark
Initial value
Table. 5-1-2.
5-10
DCR-TRV240E/TRV340E
1-2-2.
INITIALIZATION OF A, D PAGE DATA
(DCR-TRV340E)
Note:
The data of page: 0, address: 10 must be “00”.
1. Initializing the A, D Page Data
Note1: If “Initializing the A, D Page Data” is performed, all data
of the A page and D page will be initialized. (It is
impossible to initialize a single page.)
Note2:
If the A, D page data has been initialized, the following adjustments
need to be performed again.
1) Modification of A, D page data
Note3:
The power supply voltage must be 6.0 ± 0.1Vdc.
Adjusting page
D
Adjusting Address
10 to 67
Adjusting page
A
Adjusting Address
10 to FF
Initializing Method:
Order Page Address Data
Procedure
1
0
01
01
Set the data
2
0
10
00
Set the data
3
7
03
80
Set the data
4
7
00
28
Set the data
5
7
01
28
Set the data, and press the PAUSE
button.
6
7
02
Check that the data changes to
“01”
7
2
00
29
Set the data
8
2
01
29
Set the data, and press the PAUSE
button.
9
Perform “Modification of A, D
Page Data”.
2. Modification of A, D Page Data
If the A, D page data has been initialized, change the data of the
“Fixed data-2” address shown in the following tables by manual
input.
Modifying Method:
1)
Before changing the data, select page: 0, address: 01, and set
data: 01.
2)
New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note:
If copy the data built in the different model, the camcorder may
not operate.
3)
When changing the data, press the PAUSE button of the
adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
Processing after Completing Modification of A, D Page data
Order Page Address Data
Procedure
1
2
00
29
Set the data.
2
2
01
29
Set the data, and press PAUSE
button.
Note:
If the following symptoms occur after completing of the
“Modification of A, D page data”, check that the data of the “Fixed
data-2” addresses of D page are same as those of the same model of
the same destination.
1) The battery end mark on the LCD screen is flashing.
2) The power is shut off so that unit cannot operate.
3. D Page Table
Note1:
The data of page: 0, address: 10 must be “00”.
Note2:
Fixed data-1: Initialized data. (Refer to “1. Initializing the A, D
Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of A, D
Page Data”.)
Table. 5-1-4.
00 to 0F
10
11 to 15
16
17 to 21
22
23
24
25
26
27 to 29
2A
2B
2C to 36
37
38 to 39
3A
3B to 49
4A
4B
4C
4D
4E
4F to 67
00
Test mode
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data built
in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data built
in the same model.)
Fixed data-1
Address
Remark
Initial value
00 to 0F
10 to 17
18
19
1A
1B to 31
32
33 to 59
5A
5B to FF
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Address
Remark
Table. 5-1-3.
4. A Page Table
Note1:
The data of page: 0, address: 10 must be “00”.
Note2:
Fixed data-1: Initialized data. (Refer to “1. Initializing the A, D
Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of A, D
Page Data”.)
Page of 127
Display