Sony DCR-TRV238E / DCR-TRV239E (serv.man2) Service Manual ▷ View online
2-12
DCR-TRV238E/TRV239E
2-15.CABINET (L) SECTION
VC-276
Board
Board
8
Four
dowels
3
Claw
9
Cabinet (L)
section
5
External (hot shoe) connector,
Shoe frame
6
Two screws
(M1.7
×
2.5), p
2
Screw
(M1.7
×
2.5), p
7
Screw
(M1.7
×
2.5), p
1
Screw
(M1.7
×
2.5), p
A
A
4
FP-264 flexible
board (15P)
PRECAUTION DURING
CABINET (L) SECTION INSTALLATION
CABINET (L) SECTION INSTALLATION
OK
NG
2-16.CS FRAME ASSEMBLY (25)
5
Cabinet (L) assembly
1
MI screw
(M2
×
4) (H)
3
Two MI screws (M2
×
4) (H)
2
Two MI screws (M2
×
4) (H)
4
Grip belt (ES)
6
CS frame assembly (25)
2-13
DCR-TRV238E/TRV239E
2-17.VC-276 BOARD
2-18.MECHANISM DECK
VC
-276
Board
D
B
A
C
E
D
E
C
B
A
7
VC sheet
8
VC-276 board
2
Screw
(M1.7
×
2.5), p
4
Two screws
(M1.7
×
2.5), p
5
3
FP-410
flexible board
6
FP-264 flexible
board (20P)
1
MI screw
(M2
×
4) (H)
5
MD frame
4
1
Turn over VC-276 board
in the direction of the arrow.
6
Mechanism
deck
VC-276
Board
2
Three screws
(M1.7
×
2.5), p
3
Three dowels
2-14
DCR-TRV238E/TRV239E
Adjustment remote
commander (RM-95)
commander (RM-95)
AC IN
DC IN
AC POWER
ADAPTOR
ADAPTOR
FP-406 flexible
board (30P)
board (30P)
Control switch block
(SS-1380) (12P)
(SS-1380) (12P)
Mechanism deck
CPC-13 jig
(J-6082-443-A)
(J-6082-443-A)
FP-410
flexible board
flexible board
FP-411
flexible board
flexible board
SI-032 board
Battery panel
section
section
Battery terminal
board (6P)
board (6P)
VC-276
board
board
LANC
jack
jack
VC-276
Board
Cabinet (R) block section
(Raise the hook in the direction of the arrow
A
.)
How to raise the cassette
compartment manually
compartment manually
Control switch block
(CF-2500) (22P)
(CF-2500) (22P)
Harness
(PD-117) (20P)
(PD-117) (20P)
CN1109
CN1108
12
2
To eject the cassette, short the circuit
between pin
between pin
qs
and pin
2
(GND) of
CN1109 on VC-276 board for 1 second.
To check the VTR section, set the VTR to the “Forced VTR power ON” mode.
Operate the VTR functions using the adjustment remote commander (with the HOLD switch set in the OFF position).
Operate the VTR functions using the adjustment remote commander (with the HOLD switch set in the OFF position).
[SERVICE POSITION TO CHECK THE VTR SECTION]
Setting the “Forced VTR Power ON” mode
Cnnection to Check the VTR Section
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 0, address: 10, and set data: 00.
3) Select page: D, address: 10, set data: 02 and
2) Select page: 0, address: 10, and set data: 00.
3) Select page: D, address: 10, set data: 02 and
press the PAUSE button of the adjustment remote
commander.
commander.
Exiting the “Forced VTR Power ON” mode
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 0, address: 10, and set data: 00.
3) Select page: D, address: 10, set data: 00, and press
the PAUSE button of the adjustment remote commander.
4) Select page: 0, address: 01, and set data: 00.
2) Select page: 0, address: 10, and set data: 00.
3) Select page: D, address: 10, set data: 00, and press
the PAUSE button of the adjustment remote commander.
4) Select page: 0, address: 01, and set data: 00.
Note : If the machine malfunctions (the operating mode changes by itself), connect the Cabinet (R) section.
A
2-15
DCR-TRV238E/TRV239E
Adjustment remote
commander (RM-95)
commander (RM-95)
AC IN
DC IN
AC POWER
ADAPTOR
ADAPTOR
FP-406 flexible
board (30P)
board (30P)
Control switch block
(SS-1380) (12P)
(SS-1380) (12P)
Mechanism deck
FP-410
flexible board
flexible board
FP-161 flexible
board (16P)
board (16P)
Iris flexible
assembly (24P)
assembly (24P)
Battery panel
section
section
Battery terminal
board (6P)
board (6P)
VC-276
board
board
Lens section
LANC
jack
jack
SI-032 board
VC-276
Board
CD-357 board
Cabinet (R) block section
Control switch block
(CF-2500) (22P)
(CF-2500) (22P)
Harness
(PD-117) (20P)
(PD-117) (20P)
[SERVICE POSITION TO CHECK THE CAMERA SECTION]
Note : If the machine malfunctions (the operating mode changes by itself), connect the Cabinet (R) section.
Connection to Check the Camera Section
To check the camera section, set the camera to the “Forced camera power ON” mode.
When you want to operate to zoom and focus, use the controls on the remote commander (with the HOLD switch off).
When you want to operate to zoom and focus, use the controls on the remote commander (with the HOLD switch off).
Setting the “Forced Camera Power ON” mode
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 0, address: 10, and set data: 00.
3) Select page: D, address: 10, set data: 01 and
2) Select page: 0, address: 10, and set data: 00.
3) Select page: D, address: 10, set data: 01 and
press the PAUSE button of the adjustment remote
commander.
commander.
Exiting the “Forced Camera Power ON” mode
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 0, address: 10, and set data: 00.
3) Select page: D, address: 10, set data: 00, and press
the PAUSE button of the adjustment remote
commander.
4) Select page : 0, address: 01, and set data: 00.
2) Select page: 0, address: 10, and set data: 00.
3) Select page: D, address: 10, set data: 00, and press
the PAUSE button of the adjustment remote
commander.
4) Select page : 0, address: 01, and set data: 00.
FP-411
flexible board
flexible board
Click on the first or last page to see other DCR-TRV238E / DCR-TRV239E (serv.man2) service manuals if exist.