DOWNLOAD Sony DCR-TRV22 / DCR-TRV22E (serv.man4) Service Manual ↓ Size: 1.44 MB | Pages: 67 in PDF or view online for FREE

Model
DCR-TRV22 DCR-TRV22E (serv.man4)
Pages
67
Size
1.44 MB
Type
PDF
Document
Service Manual
Brand
Device
Movie / SECTION 6 ADJUSTMENTS
File
dcr-trv22-dcr-trv22e-sm4.pdf
Date

Sony DCR-TRV22 / DCR-TRV22E (serv.man4) Service Manual ▷ View online

6-10
DCR-TRV22/TRV22E
Address
Remark
Initial value
Table. 6-1-3.
4. D Page Table
Note1:
The data of page: 0, address: 10 must be “00”.
Note2:
Fixed data-1: Initialized data. (Refer to “1. Initializing the A, D
Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of A, D
Page Data”.)
Test mode
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed dat a-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
00 to 0F
10
11
12
13 to 15
16
17 to 22
23
24
25
26
27 to 29
2A
2B
2C to 35
36
37
38
39
3A
3B to 57
58
59
5A to 6E
6F
70 to 7F
00
6-11
DCR-TRV22/TRV22E
1-2-2.
INITIALIZATION OF B, 1B PAGE DATA
Note:
When reading or writing the B page data, select page: 0, address:
10, and set data: 00.
When reading or writing the 1B page data, select page: 0, address:
10, and set data: 01, then select B page. The 1B page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
1. Initializing the B, 1B Page Data
Note1: If “Initializing the B, 1B Page Data” is performed, all data
of the B page and 1B page will be initialized. (It is
impossible to initialize a single page.)
Note2:
If the B, 1B page data has been initialized, the following
adjustments need to be performed again.
1) Modification of B, 1B page data
Note3:
The power supply voltage must be 6.0 ± 0.1Vdc.
Adjusting page
B
Adjusting Address
00 to FF
Adjusting page
1B
Adjusting Address
00 to FF
Initializing Method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
0
10
00
Set the data.
3
5
02
FF
Set the data, and press PAUSE
button.
4
5
01
F3
Set the data, and press PAUSE
button.
5
5
00
01
Set the data, and press PAUSE
button.
6
5
02
Check that the data changes to
“00”.
7
Perform “Modification of B, 1B
Page Data”.
2. Modification of B, 1B Page Data
If the B, 1B page data has been initialized, change the data of the
“Fixed data-2” address shown in the following tables by manual
input.
Modifying Method:
1)
Before changing the data, select page: 0, address: 01, and set
data: 01.
2)
When changing the B page data, select page: 0, address: 10,
and set data: 00.
3)
When changing the 1B page data, select page: 0, address: 10,
and set data: 01.
After completing the modification of 1B page data, reset the
data of this address to “00”.
4)
New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note:
If copy the data built in the different model, the camcorder may
not operate.
5)
When changing the data, press the PAUSE button of the
adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
Processing after Completing Modification of B, 1B Page data:
Order Page Address Data
Procedure
1
0
10
00
Set the data.
2
2
00
29
Set the data.
3
2
01
29
Set the data, and press PAUSE
button.
3. B Page Table
Note1:
The data of page: 0, address: 10 must be “00”.
Note2:
Fixed data-1: Initialized data. (Refer to “1. Initializing the B, 1B
Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of B, 1B
Page Data”.)
Table. 6-1-4.
4. 1B Page Table
Note1:
When reading or writing the 1B page data, select page: 0, address:
10, and set data: 01, then select B page. The 1B page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
Note2:
Fixed data-1: Initialized data. (Refer to “1. Initializing the B, 1B
Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of B, 1B
Page Data”.)
Table. 6-1-5.
Address
00 to 02
03
04 to FF
Remark
Fixed data-1
Fixed data-2
Fixed data-1
Address
00 to FF
Remark
Fixed data-1
6-12
DCR-TRV22/TRV22E
1-2-3.
INITIALIZATION OF 8, C, 18, 1C PAGE DATA
Note:
When reading or writing the 8, C page data, select page: 0, address:
10, and set data: 00.
When reading or writing the 18, 1C page data, select page: 0, address:
10, and set data: 01, then select 8 or C page. The 18 or 1C page can
be chosen by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
1. Initializing the 8, C, 18, 1C Page Data
Note1: If “Initializing the 8, C, 18, 1C Page Data” is performed,
all data of the 8 page, C page, 18 page and 1C page will
be initialized. (It is impossible to initialize a single page.)
Note2:
If the 8, C, 18, 1C page data has been initialized, following
adjustments need to be performed again.
1) Modification of 8, C, 18, 1C page data
2) Viewfinder system adjustments
3) LCD system adjustments
4) Serial No. input
5) Servo and RF system adjustments
6) Video system adjustments
Note3:
The power supply voltage must be 6.0 ± 0.1Vdc.
Adjusting page
8
Adjusting Address
00 to FF
Adjusting page
C
Adjusting Address
10 to FF
Adjusting page
18
Adjusting Address
00 to FF
Adjusting page
1C
Adjusting Address
00 to FF
Initializing Method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
0
10
00
Set the data.
3
3
81
Check that the data is “00”.
4
3
80
0C
Set the data, and press PAUSE
button.
5
3
80
Check that the data changes to
“1C”.
6
Perform “Modification of 8, C,
18, 1C Page Data”.
2. Modification of 8, C, 18, 1C Page Data
If the 8, C, 18, 1C page data has been initialized, change the data of
the “Fixed data-2” address shown in the following table by manual
input.
Modifying Method:
1)
Before changing the data, select page: 0, address: 01, and set
data: 01.
2)
When changing the 8, C page data, select page: 0, address: 10,
and set data: 00.
3)
When changing the 18, 1C page data, select page: 0, address:
10, and set data: 01.
After completing the modification of 18, 1C page data, reset
the data of this address to “00”.
4)
New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note:
If copy the data built in the different model, the camcorder may
not operate.
5)
When changing the data, press the PAUSE button of the
adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
6)
Check that the data of adjustment addresses is the initial value.
If not, change the data to the initial value.
Processing after Completing Modification of 8, C, 18, 1C
Page data
Order Page Address Data
Procedure
1
0
10
00
Set the data.
2
2
00
29
Set the data.
3
2
01
29
Set the data, and press PAUSE
button.
6-13
DCR-TRV22/TRV22E
3. 8 Page Table
Note1:
The data of page: 0, address: 10 must be “00”.
Note2:
Fixed data-1: Initialized data. (Refer to “1. Initializing the 8, C,
18, 1C Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of 8, C,
18, 1C Page Data”.)
Table. 6-1-6.
4. C Page Table
Note1:
The data of page: 0, address: 10 must be “00”.
Note2:
Fixed data-1: Initialized data. (Refer to “1. Initializing the 8, C,
18, 1C Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of 8, C,
18, 1C Page Data”.)
Address
Remark
Initial value
Address
Remark
Initial value
00 to 0F
10
11
12
13
14 to 15
16
17 to 24
25
26
27
28 to 33
34
35
36
37
38
39
3A to 3B
3C
3D
3E
3F
40
41 to 44
45
46
47
48
49
4A
4B
4C
4D
4E
4F
50
51 to 52
53
54
55 to 57
58
59 to 60
61
62
63
64
65 to 9B
EE
00
00
00
E0
86
7D
59
70
6F
9E
80
74
24
70
70
24
A0
06
45
7A
5F
1C
42
Switching position adj.
Fixed data-1
CAP FG duty adj.
Fixed data-1
S VIDEO out Y level adj.
S VIDEO out Cr level adj.
S VIDEO out Cb level adj.
Fixed data-1
Fixed data-2
VCO adj. (EVF)
Fixed data-1
RGB AMP adj. (EVF)
Fixed data-1
White balance adj. (EVF)
Contrast adj. (EVF)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
VCO adj. (LCD)
V COM adj. (LCD)
RGB AMP adj. (LCD)
Black limit adj. (LCD)
PSIG GRAY adj. (LCD)
White balance adj. (LCD)
Contrast adj. (LCD)
Center level adj. (LCD)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Remark
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in the same
model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in the same
model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Address
00 to 29
2A
2B to 33
34
35 to 4E
4F
50 to 7A
7B
7C
7D to 88
89
8A
8B to 91
92
93 to 94
95
96 to AC
AD
AE to B0
B1
B2
B3
B4 to B5
B6
B7 to BE
BF
CO to C7
C8
C9
CA
CB
CC
CD to D5
D6
D7
D8 to FF
Page of 67
Display

Click on the first or last page to see other DCR-TRV22 / DCR-TRV22E (serv.man4) service manuals if exist.