Sony DCR-TRV16 / DCR-TRV16E / DCR-TRV18 / DCR-TRV18E (serv.man2) Service Manual ▷ View online

5-53
DCR-TRV16/TRV16E/TRV18/TRV18E/TRV116E/TRV118E
4-2.
DATA PROCESS
The calculation of the DDS display and the adjustment remote
commander display data (hexadecimal notation) are required for
obtaining the adjustment data of some adjustment items. In this case,
after converting the hexadecimal notation to decimal notation,
calculate and convert the result to hexadecimal notation, and use it
as the adjustment data. Indicates the hexadecimal-decimal
conversion table.
Hexadecimal-decimal Conversion Table
Lower digit of
hexadecimal 
Upper digit 
of hexadecimal
0
1
2
3
4
5
6
7
8
9
A
(
A
)
B
(
b
)
C
(
c
)
D
(
d
)
E
(
E
)
F
(
F
)
0
1
2
3
4
5
6
7
8
9
A (
A
)
B (
b
)
C (
c
)
D (
d
)
E (
E
)
F (
F
)
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
174
159
175
160
161
162
163
164
165
166
167
168
169
170
171
172
173
177
176
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
0
1
Note :
The characters shown in the parenthesis (  ) shown the display on the adjustment remote commander.
(Example)
If the DDS display or the adjustment remote commander shows BD (
bd
);
Because the upper digit of the adjustment number is B (
b
), and the lower digit is D (
d
), the meeting point 
“189” of 1 and 2 in the above table is the corresponding decimal number.
0
2
Table. 5-4-1.
5-54
DCR-TRV16/TRV16E/TRV18/TRV18E/TRV116E/TRV118E
4-3.
SERVICE MODE
Note:
Before performing the adjustments, check the data of page: 0,
address: 10 is “00”. If not, set data: 00 to this address.
1. Setting the Test Mode
Page D
Address 10
• Before setting the data , select page: 0, address: 01, and set data:
01.
• For page D, the data set is recorded in the non-volatile memory
by pressing the PAUSE button of the adjustment remote
commander. In this case, take note that the test mode will not be
exited even when the main power is turned off.
• After completing adjustments/repairs, be sure to return the data
of this address to 00, and press the PAUSE button of the adjustment
remote commander.
Select page: 0, address: 01, and set data: 00.
2. Emergence Memory Address
Page C
Address F4 to FF
When no error occurs in this unit, data “00” is written in the above
addresses (F4 to FF). when first error occurs in the unit, the data
corresponding to the error is written in the first emergency address
(F4 to F7). In the same way, when the second error occurs, the data
corresponding to the error is written in the second emergency address
(F8 to FB). Finally, when the last error occurs, the data corresponding
to the error is written in the last emergency address (FC to FF).
Note:
After completing adjustments, be sure to initialize the data of
addresses F4 to FF to “00”.
Initializing method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 3, address: 01, set data: 37, and press the PAUSE
button.
3)
Select page: 0, address: 01, and set data: 00.
Contents
EMG code when first error occurs
Upper: MSW code when shift starts when first
error occurs
Lower: MSW code when first error occurs
Lower: MSW code to be moved when first error
occurs
EMG code when second error occurs
Upper: MSW code when shift starts when second
error occurs
Lower: MSW code when second error occurs
Lower: MSW code to be moved when second error
occurs
EMG code when last error occurs
Upper: MSW code when shift starts when last error
occurs
Lower: MSW code when last error occurs
Lower: MSW code to be moved when last error
occurs
Address
F4
F6
F7
F8
FA
FB
FC
FE
FF
2-1. EMG Code (Emergency Code)
Codes corresponding to the errors which occur are written in
addresses F4, F8 and FC. The type of error indicated by the code
are shown in the following table.
Emergency Type
No error
Loading motor emergency during loading
Loading motor emergency during unloading
T reel emergency during normal rotation
S reel emergency during normal rotation
T reel emergency (Short circuit between S reel
terminal and T reel terminal)
FG emergency at the start up of the capstan
FG emergency at the start up of the drum
FG emergency during normal rotation of the drum
Code
00
10
11
22
23
24
30
40
42
Function
Normal
Forced camera power ON
Forced VTR power ON
Forced camera + VTR power ON
Forced memory power ON
Data
00
01
02
03
05
5-55
DCR-TRV16/TRV16E/TRV18/TRV18E/TRV116E/TRV118E
0010=2
1110=E
 
← 
UNLOAD
Lock released
Cassette compartment
Pinch roller pressing
LS chassis movement section
EJ
BL
1010=A
1110=E
ULE
BL
1000=8
1110=E
SR
BL
1100=C
1110=E
GL
BL
0100=4
1110=E
STOP
BL
0110=6
R/P
LOAD 
 A (MSB) 
 B
 C
 D (LSB) (Fixed at “0”)
Mechanical Position
Position
EJ
BL
ULE
SR
GL
STOP
R/P
NULL
Code
2
E
A
8
C
4
6
0
F
Contents
Position at which the cassette component lock is released, at the farthest unload side mechanically
at which the mechanism can move no further in the UNLOAD direction.
BLANK code, at the boundary between codes.
EJECT completion position. when the cassette is ejected, the mechanism will stop at this position.
Cassette IN standby. The guide will start protruding out as the mechanism moves towards the
LOAD position.
Position at which it is possible to release the S ratchet.
Guide loading are performed here.
Stop position in the loading state. The pinch roller separates, the tension regulator returns, and the
brake is imposed on both reels.
PB, REC, CUE, REVIEW, PAUSE positions. When pinch roller is pressed, and the tension
regulator is ON, the mechanism is operating at this position in modes in which normal images are
shown.
Code not existing in the MD. Default value.
Status before finding any mechanism position.
2-2. MSW Code
MSW when errors occur:
Information on MSW (mode SW) when errors occur
MSW when movement starts:
 Information on MSW when movements starts when the mechanism position is moved (When the L motor is moved)
MSW of target of movement:
 Information on target MSW of movement when the mechanism position is moved
5-56
DCR-TRV16/TRV16E/TRV18/TRV18E/TRV116E/TRV118E
Display on the
adjustment
remote
commander
0
1
2
3
4
5
6
7
8
9
A (
A
)
B (
b
)
C (
c
)
D (
d
)
E (
E
)
F (
F
)
Bit values
bit3
or
bit7
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
bit2
or
bit6
0
0
0
0
1
1
1
1
0
0
0
0
1
1
1
1
bit1
or
bit5
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
bit0
or
bit4
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
B
Example:
If “8E” is displayed on the adjustment remote commander, the
bit values for bit7 to bit4 are shown in the A column, and the
bit values for bit3 to bit0 are shown in the B column.
Page
Address
bit3 to bit0 discrimination
bit7 to bit4 discrimination
Display on the adjustment remote commander
3. Bit value discrimination
Bit values must be discriminated using the display data of the
adjustment remote commander for following items. Use the table
below to discriminate if the bit value is “1” or “0”.
A
4. Switch check (1)
Page 7
Address 0E
Note:
The data of page: 0, address: 10 must be “00”.
Bit
1
2
3
Function
MIC jack (MA-409 board J5901)
AUDIO/VIDEO jack (JK-217 board J5302)
S VIDEO jack (JK-217 board J5302)
When bit value=1
Used
Used
Used
When bit value=0
Not used
Not used
Not used
Bit
0
1
2
3
4
5
6
7
Function
POWER SW (VTR MODE SW) (PS-CX2670 block S001)
POWER SW (CAM MODE SW) (PS-CX2670 block S001)
START/STOP SW (PS-CX2670 block S002)
EJECT SW (FP-443 flexible S201)
CC DOWN SW (Mechanism chassis)
PHOTO FREEZE SW (PS-CX2670 block S071)
POWER SW (PHOTO STBY SW) (PS-CX2670 block S001)
When bit value=1
ON (VCR/PLAYER)
ON (CAMERA)
ON
ON
ON (DOWN)
ON
ON (MEMORY)
When bit value=0
OFF
OFF
OFF
OFF
OFF (UP)
OFF
OFF
Using method:
1)
Select page: 7, address: 0E.
2)
By discriminating the bit value of display data, the state of the switch can be discriminated.
5. Switch check (2)
Page 7
Address 0C
Note:
The data of page: 0, address: 10 must be “00”.
Using method:
1)
Select page: 7, address: 0C.
2)
By discriminating the bit value of display data, the state of the switch can be discriminated.
Page of 127
Display

Sony DCR-TRV16 / DCR-TRV16E / DCR-TRV18 / DCR-TRV18E (serv.man2) Service Manual ▷ Download