DOWNLOAD Sony DCR-TRV145E / DCR-TRV147E / DCR-TRV245E / DCR-TRV250E (serv.man3) Service Manual ↓ Size: 1.73 MB | Pages: 64 in PDF or view online for FREE

Model
DCR-TRV145E DCR-TRV147E DCR-TRV245E DCR-TRV250E (serv.man3)
Pages
64
Size
1.73 MB
Type
PDF
Document
Service Manual
Brand
Device
Movie / SECTION 6 ADJUSTMENTS
File
dcr-trv145e-dcr-trv147e-dcr-trv245e-dcr-trv250e-sm.pdf
Date

Sony DCR-TRV145E / DCR-TRV147E / DCR-TRV245E / DCR-TRV250E (serv.man3) Service Manual ▷ View online

DCR-TRV145E/TRV147E/TRV245E/TRV250E
6-3
• Adjusting items when replacing a board or EEPROM
When replacing a board or EEPROM, adjust the items indicated by z in the following table.
Table 6-1-1 (2)
Replaced part
Adjustment Section
Adjustment
(COMPLETE)
(COMPLETE)
(EEP ROM)
PD-180 board
VC-304 board
VC-304 board IC4502
Supporting
Initialization of 8, A, C,
Initializing of A, D page data
z
z
D, E, F, 1C page data
Initializing of 8, C, 1C page data
z
z
Initializing of E, F page data
z
z
Camera
HALL adj.
z
z
z
Flange back adj.
z
z
z
Optical axis adj.
z
z
Color reproduction adj.
z
z
LV standard data input
z
z
z
AWB standard data input
z
z
z
Auto white balance adj.
z
z
z
Angular velocity sensor output check
and steadyshot check (Note 3)
z
z
z
EVF
VCO adj.
z
z
RGB AMP adj.
z
z
z
Contrast adj.
z
z
z
LCD
VCO adj.
z
z
z
RGB AMP adj.
z
z
z
Contrast adj.
z
z
z
COM AMP adj.
z
z
z
V-COM adj.
z
z
z
White balance adj.
z
z
z
System control
Node uniqe ID No. input
z
z
Servo, RF
REEL FG adj.
z
z
z
CAP FG duty adj.
z
z
z
Switching position adj.
z
z
z
SD error rate check (LP)
z
z
z
Video
27 MHz origin osillation adj.
z
z
S VIDEO OUT Y level adj.
z
z
S VIDEO OUT C level adj.
z
z
Mechanism
Tape path adj.
RadarW
RadarW
RadarW
DCR-TRV145E/TRV147E/TRV245E/TRV250E
6-4
COVER
COVER
J-1
J-2
J-6
J-3
J-7
J-8
J-4
J-5
Fig. 6-1-1
J-9
J-10
J-11
Ref. No.
J-1
J-2
J-3
J-4
J-5
J-6
J-7
J-8
J-9
J-10
J-11
J-12
Name
Filter for color temperature correction (C14)
ND filter 1.0
ND filter 0.4
ND filter 0.1
Pattern box PTB-450
Color chart for pattern box
Adjustment remote commander (RM-95 upgraded).
Siemens star chart
Clear chart for pattern box
CPC jig connector
I/F unit for LANC control
Mini pattern box
Camera table
Multi CPC jig
Parts Code
J-6080-058-A
J-6080-808-A
J-6080-806-A
J-6080-807-A
J-6082-200-A
J-6020-250-A
J-6082-053-B
J-6080-875-A
J-6080-621-A
J-6082-539-A
J-6082-521-A
J-6082-353-B
J-6082-384-A
J-6082-311-A
Usage
Auto white balance adjustment/check
White balance adjustment/check
White balance check
White balance check
White balance check
For checking the flange back
For connecting the adjustment remote commander
For connecting the adjustment remote commander
For adjusting the flange back
For adjusting the flange back
For adjusting the LCD system
6-1. CAMERA SECTION ADJUSTMENTS
1-1.
PREPARATIONS BEFORE ADJUSTMENTS (CAMERA SECTION)
1-1-1.
List of Service Tools
• Oscilloscope
• Color monitor
• Vectorscope
• Regulated power supply
• Digital voltmeter
• Frequency counter
J-12
DCR-TRV145E/TRV147E/TRV245E/TRV250E
6-5
Fig. 6-1-2
1-1-2. Preparations
Note 1:
For details of how remove the cabinet and boards, refer
to “2. DISASSEMBLY”.
Note 2:
When performing only the adjustments, the lens block
and boards need not be disassembled.
1) Connect the equipment for adjustments according to Fig. 6-1-
4.
2) Connect the adjustment remote commander to VC-304 board
CN1011 via I/F unit for LANC control (J-6082-521-A) and
CPC jig connector (J-6082-539-A). (Fig. 6-1-3)
To operate the adjustment remote commander, connect the AC
power adaptor to the DC IN jack of I/F unit for LANC control,
or connect the L series Info-LITHIUM battery to the battery
terminal of I/F unit for LANC control.
3) The front panel block (SI-035 board,  video light, microphone
unit) need not be assembled except during the steadyshot op-
eration check.
Note 3:
As removing the cabinet (R) (removing the VC-304 board
CN1007) means removing the lithium 3V power supply
(CF-3000 block BT001), data such as date, time, user-
set menus will be lost. After completing adjustments,
reset these data. If the cabinet (R) has been removed, the
self-diagnosis data, data on history of use (total drum
rotation time, etc. ) will be lost. Before removing, note
down the self-diagnosis data (data of page: 7, address:
B0 to C6) and data on history use (data of page: 7, ad-
dress: A7 to A9 and C8 to CF). (Refer to “SELF-DIAG-
NOSIS FUNCTION” for the self-diagnosis data, and to
“6-4. Service Mode” for the data on the history use)
Note 4:
Setting the “Forced Camera Power ON” Mode
1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, address: 10, set data: 01, and press
the PAUSE button of the adjustment remote com-
mander.
The above procedure will enable the camera power
to be turned on with the power switch (SS-3000 block)
removed. After completing adjustments, be sure to
exit the “Forced Camera Power ON Mode”.
Note 5:
Exiting the “Forced Camera Power ON” Mode
1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, address: 10, set data: 00, and press
the PAUSE button of the adjustment remote com-
mander.
3) Select page: 0, address: 01, and set data: 00.
Fig. 6-1-3
Front of the lens
1.5 m
Pattern box
CN1011
16
1
Conductor 
side
DCR-TRV145E/TRV147E/TRV245E/TRV250E
6-6
Fig. 6-1-4
Adjustment
remote commander
L series
Info LITHIUM
battery
(7.2 Vdc)
LANC
jack
I/F unit for LANC control
(J-6082-521-A)
Must be connected
AC power adaptor
AC power adaptor
PD-180 board
CABINET (R)
LENS BLOCK
EVF BLOCK
FRONT PANEL BLOCK
CN5501
CN5601
CN5701
CN5702
CN5502
VC-304 board
DC IN jack
To CONTROL SWITCH BLOCK (CF-3000)
To PD-180 board CN5701
FP-577 flexible
CD-418 board
CN2403
CN3201
CN2404
CN951
CN1005
CN1551
CN1001
CN1011
CN1501
CN1003
CN1002
CN1009
CN4001
CN2402
CN2401
CN1007
CPC jig connector
Video
(yellow)
Color monitor
Vector scope
Terminated
75 
Audio R (red)
Audio L (white)
Multi CPC jig
(J-6082-311-A)
Must be connected when performing
the LCD sytem adjustment.
Must be connected when performing
the EVF sytem adjustment.
Must be connected 
when performing
the steadyshot check.
(J-6082-539-A)
To SI-035 board
CN753
Note:
Use either the AC power adaptor or the InfoLITHIUM battery as the power supply of I/F unit for LANC control.
Page of 64
Display