DOWNLOAD Sony DCR-TRV12E / DCR-TRV14E / DCR-TRV19 / DCR-TRV19E (serv.man4) Service Manual ↓ Size: 1.26 MB | Pages: 59 in PDF or view online for FREE

Model
DCR-TRV12E DCR-TRV14E DCR-TRV19 DCR-TRV19E (serv.man4)
Pages
59
Size
1.26 MB
Type
PDF
Document
Service Manual
Brand
Device
Movie / SECTION 6 ADJUSTMENTS
File
dcr-trv12e-dcr-trv14e-dcr-trv19-dcr-trv19e-sm4.pdf
Date

Sony DCR-TRV12E / DCR-TRV14E / DCR-TRV19 / DCR-TRV19E (serv.man4) Service Manual ▷ View online

6-8
DCR-TRV12E/TRV14E/TRV19/TRV19E
1-2.
INITIALIZATION OF 8, A, C, D, E, F, 1C
PAGE DATA
Note:
When reading or writing the 1C page data, select page: 0, address:
10, and set data: 01, then select C page. The 1C page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
[Connection of the power supply during the initialization
of the data.]
1)
Connect the regulated power supply and the digital voltmeter
to the battery terminal as shown in Fig. 6-1-6.
2)
Adjust the output voltage of the regulated power supply so that
the digital voltmeter display is 6.0 ± 0.1Vdc.
3)
Turn off the power supply.
4)
Turn on the HOLD switch of the adjusting remote commander.
5)
Turn on the power supply.
6)
Perform the initialization of the data.
Note:
This is normal though the following message is indicated on the
LCD screen.
“FOR InfoLITHIUM BATTERY ONLY”
[Initialization Procedure]
1.
Initialization of A, D page data
2.
Initialization of 8, C, 1C page data
3.
Initialization of E, F page data
fig. 6-1-6
Regulated power supply
Battery terminal
Digital volt meter
COVER
COVER
6-9
DCR-TRV12E/TRV14E/TRV19/TRV19E
1-2-1.
INITIALIZATION OF A, D PAGE DATA
Note:
The data of page: 0, address: 10 must be “00”.
1. Initializing the A, D Page Data
Note1:
If “Initializing the A, D Page Data” is performed, all data of the A
page and D page will be initialized. (It is impossible to initialize a
single page.)
Note2:
If the A, D page data has been initialized, the following adjustments
need to be performed again.
1) Modification of A, D page data
2) Touch panel adjustment
Note3:
The power supply voltage must be 6.0 ± 0.1Vdc.
Note4:
NTSC model: DCR-TRV19
PAL model: DCR-TRV12E/TRV14E/TRV19E
Adjusting page
A
Adjusting Address
10 to 90
Adjusting page
D
Adjusting Address
10 to 6F
Initializing Method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
0
10
00
Set the data.
3
7
03
Set the following data.
01 (NTSC), 81 (PAL)
4
7
00
Set the following data.
20 (Initializing A page)
22 (Initializing D page)
28 (Initializing A and D pages)
5
7
01
Set the following data, and press
PAUSE button.
20 (Initializing A page)
22 (Initializing D page)
28 (Initializing A and D pages)
6
7
02
Check that the data changes to “01”
7
Perform “Modification of A, D
Page Data”.
2. Modification of A, D Page Data
If the A, D page data has been initialized, change the data of the
“Fixed data-2” address shown in the following tables by manual
input.
Modifying Method:
1)
Before changing the data, select page: 0, address: 01, and set
data: 01.
2)
New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note:
If copy the data built in the different model, the camcorder may
not operate.
3)
When changing the data, press the PAUSE button of the
adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
Processing after Completing Modif
ication of A, D Page data
Order Page Address Data
Procedure
1
2
00
29
Set the data.
2
2
01
29
Set the data, and press PAUSE
button.
Note:
If the following symptoms occur after completing of the
“Modification of A, D page data”, check that the data of the “Fixed
data-2” addresses of A and D page are same as those of the same
model of the same destination.
1) The self-diagnosis code “E:20:00” on the LCD screen is displayed.
2) The power is shut off so that unit cannot operate.
3. A Page Table
Note1:
The data of page: 0, address: 10 must be “00”.
Note2:
Fixed data-1: Initialized data. (Refer to “1. Initializing the A, D
Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of A, D
Page Data”).
Table. 6-1-2.
4. D Page Table
Note1:
The data of page: 0, address: 10 must be “00”.
Note2:
Fixed data-1: Initialized data. (Refer to “1. Initializing the A, D
Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of A, D
Page Data”).
Address
Remark
Initial value
Initial value
NTSC PAL
00 to 0F
10 to 29
2A
2B to 2C
2D
2E to 81
82
83
84
85
86 to 90
DA
27
E1
1C
DB
25
DA
23
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Touch panel adj.
Fixed data-1
Table. 6-1-3.
Address
Remark
Initial value
Address
Remark
Initial value
00 to 0F
10
11
12
13 to 57
58
59 to 6E
6F
00
Test mode
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
6-10
DCR-TRV12E/TRV14E/TRV19/TRV19E
1-2-2.
INITIALIZATION OF 8, C, 1C PAGE DATA
Note:
When reading or writing the 8, C page data, select page: 0, address:
10, and set data: 00.
When reading or writing the 1C page data, select page: 0, address:
10, and set data: 01, then select C page. The 1C page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
1. Initializing the 8, C, 1C Page Data
Note1:
If “Initializing the 8, C, 1C Page Data” is performed, all data of
the 8 page, C page and 1C page will be initialized. (It is impossible
to initialize a single page.)
Note2:
If the 8, C, 1C page data has been initialized, following adjustments
need to be performed again.
1) Modification of 8, C, 1C page data
2) Viewfinder system adjustments
3) LCD system adjustments
4) Serial No. input
5) Servo and RF system adjustments
6) Video system adjustments
Note3:
The power supply voltage must be 6.0 ± 0.1Vdc.
Adjusting page
8
Adjusting Address
00 to FF
Adjusting page
C
Adjusting Address
10 to FF
Adjusting page
1C
Adjusting Address
00 to FF
Initializing Method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
0
10
00
Set the data.
3
3
81
Check that the data is “00”.
4
3
80
0C
Set the data, and press PAUSE
button.
5
3
80
Check that the data changes to
“1C”.
6
Perform “Modification of 8, C,
1C Page Data”.
2. Modification of 8, C, 1C Page Data
If the 8, C, 1C page data has been initialized, change the data of the
“Fixed data-2” address shown in the following table by manual input.
Modifying Method:
1)
Before changing the data, select page: 0, address: 01, and set
data: 01.
2)
When changing the 8, C page data, select page: 0, address: 10,
and set data: 00.
3)
When changing the 1C page data, select page: 0, address: 10,
and set data: 01.
After completing the modification of 1C page data, reset the
data of this address to “00”.
4)
New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note:
If copy the data built in the different model, the camcorder may
not operate.
5)
When changing the data, press the PAUSE button of the
adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
6)
Check that the data of adjustment addresses is the initial value.
If not, change the data to the initial value.
Processing after Completing Modif
ication of 8, C, 1C Page data
Order Page Address Data
Procedure
1
0
10
00
Set the data.
2
2
00
29
Set the data.
3
2
01
29
Set the data, and press PAUSE
button.
6-11
DCR-TRV12E/TRV14E/TRV19/TRV19E
3. 8 Page Table
Note1:
The data of page: 0, address: 10 must be “00”.
Note2:
Fixed data-1: Initialized data. (Refer to “1. Initializing the 8, C,
1C Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of 8, C,
1C Page Data”).
Table. 6-1-4.
4. C Page Table
Note1:
The data of page: 0, address: 10 must be “00”.
Note2:
Fixed data-1: Initialized data. (Refer to “1. Initializing the 8, C,
1C Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of 8, C,
1C Page Data”).
Address
Remark
00 to 33
34
35 to 4E
4F
50 to 79
7A
7B
7C
7D to 91
92
93 to AB
AC
AD to AF
B0
B1
B2 to B4
B5
B6 to B7
B8
B9
BA
BB
BC to CB
CC
CD to D5
D6
D7
D8 to FF
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2 (Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2 (Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Address
Remark
Initial value
Address
Remark
Initial value
00 to 0F
10
11
12
13
14 to 15
16
17 to 24
25
26
27
28 to 33
34
35
36
37
38
39
3A to 3D
3E
3F
40
41 to 44
45
46
47
48
49
4A
4B
4C
4D
4E
4F
50
51 to 52
53
54
55 to 57
58
59 to 60
61
62
63
64
65 to A6
A7
A8
A9
EE
00
00
00
E0
88
E3
A1
70
6F
97
37
70
70
20
9F
06
41
80
80
24
55
Switching position adj.
Fixed data-1
CAP FG duty adj.
Fixed data-1
S VIDEO out Y level adj.
S VIDEO out Cr level adj.
S VIDEO out Cb level adj.
Fixed data-1
Fixed data-2
VCO adj. (EVF)
Fixed data-1
RGB AMP adj. (EVF)
Fixed data-1
Contrast adj. (EVF)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
VCO adj. (LCD)
V COM adj. (LCD)
RGB AMP adj. (LCD)
Black limit adj. (LCD)
PSIG GRAY adj. (LCD)
White balance adj. (LCD)
Contrast adj. (LCD)
Center level adj. (LCD)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Page of 59
Display

Click on the first or last page to see other DCR-TRV12E / DCR-TRV14E / DCR-TRV19 / DCR-TRV19E (serv.man4) service manuals if exist.