Sony DCR-SX73E / DCR-SX83 / DCR-SX83E / HDR-CX110 / HDR-CX110E / HDR-CX115E / HDR-CX116E / HDR-CX150 / HDR-CX150E / HDR-CX155E / HDR-CX170 (serv.man2) Service Manual ▷ View online

– 5 –
DCR-SX73E/SX83/SX83E, HDR-CX110/CX110E/CX115E/CX116E/CX150/CX150E/CX155E/CX170_L2
SAFETY-RELATED  COMPONENT  WARNING!!
COMPONENTS IDENTIFIED BY MARK 
0 OR DOTTED LINE WITH 
MARK 
0 ON THE SCHEMATIC DIAGRAMS AND IN THE PARTS 
LIST ARE CRITICAL TO SAFE OPERATION. REPLACE THESE 
COMPONENTS WITH SONY PARTS WHOSE PART NUMBERS 
APPEAR AS SHOWN IN THIS MANUAL OR IN SUPPLEMENTS 
PUBLISHED BY SONY. 
ATTENTION AU  COMPOSANT  AYANT  RAPPORT 
À  LA  SÉCURITÉ!
LES COMPOSANTS IDENTIFIÉS PAR UNE MARQUE 
0 SUR LES 
DIAGRAMMES SCHÉMATIQUES ET LA LISTE DES PIÈCES SONT 
CRITIQUES POUR LA SÉCURITÉ DE FONCTIONNEMENT. NE 
REMPLACER CES COMPOSANTS QUE PAR DES PIÈCES SONY 
DONT LES NUMÉROS SONT DONNÉS DANS CE MANUEL OU 
DANS LES SUPPLÉMENTS PUBLIÉS PAR SONY.
Caution
Danger of explosion if battery is incorrectly replaced.
Replace only with the same or equivalent type.
Dispose of used batteries according to the instructions.
注意
電池の交換は,正しく行わないと破裂する恐れがあります。
電池を交換する場合には必ず同じ型名の電池又は同等品と
交換してください。
使用済み電池は,取扱指示に従って処分してください。
Unleaded solder
Boards requiring use of unleaded solder are printed with the leadfree 
mark (LF) indicating the solder contains no lead.
(Caution: Some printed circuit boards may not come printed with 
the lead free mark due to their particular size.)
: LEAD FREE MARK
Unleaded solder has the following characteristics.
•   Unleaded solder melts at a temperature about 40°C higher than 
ordinary solder.
Ordinary soldering irons can be used but the iron tip has to be 
applied to the solder joint for a slightly longer time.
Soldering irons using a temperature regulator should be set to 
about 350°C.
Caution:  The printed pattern (copper foil) may peel away if the 
heated tip is applied for too long, so be careful!
•   Strong viscosity
Unleaded solder is more viscous (sticky, less prone to flow) than 
ordinary solder so use caution not to let solder bridges occur such 
as on IC pins, etc.
•   Usable with ordinary solder
It is best to use only unleaded solder but unleaded solder may 
also be added to ordinary solder.
SAFETY  CHECK-OUT
After correcting the original service problem, perform the following 
safety checks before releasing the set to the customer.
1.  Check the area of your repair for unsoldered or poorly-soldered 
connections. Check the entire board surface for solder splashes 
and bridges.
2.  Check the interboard wiring to ensure that no wires are “pinched” 
or contact high-wattage resistors.
3.  Look for unauthorized replacement parts, particularly transistors, 
that were installed during a previous repair. Point them out to 
the customer and recommend their replacement.
4.  Look for parts which, through functioning, show obvious signs 
of deterioration. Point them out to the customer and recommend 
their replacement.
5.  Check the B+ voltage to see it is at the values specified.
6.  Flexible Circuit Board Repairing
 
•   Keep the temperature of the soldering iron around 270°C 
during repairing.
 
•   Do not touch the soldering iron on the same conductor of the 
circuit board (within 3 times).
 
•   Be careful not to apply force on the conductor when soldering 
or unsoldering.
1.  注意事項をお守りください。
 
サービスのとき特に注意を要する個所については,キャ
ビネット,シャーシ,部品などにラベルや捺印で注意
事項を表示しています。これらの注意書き及び取扱説
明書等の注意事項を必ずお守り下さい。
2.  指定部品のご使用を
 
セットの部品は難燃性や耐電圧など安全上の特性を
持ったものとなっています。従って交換部品は,使用
されていたものと同じ特性の部品を使用して下さい。
特に回路図,部品表に0印で指定されている安全上重
要な部品は必ず指定のものをご使用下さい。
3.  部品の取付けや配線の引きまわしはもとどおりに
 
安全上,チューブやテープなどの絶縁材料を使用した
り,プリント基板から浮かして取付けた部品がありま
す。また内部配線は引きまわしやクランパによって発
熱部品や高圧部品に接近しないよう配慮されています
ので,これらは必ずもとどおりにして下さい。
4.  サービス後は安全点検を
 
サービスのために取外したネジ,部品,配線がもとど
おりになっているか,またサービスした個所の周辺を
劣化させてしまったところがないかなどを点検し,安
全性が確保されていることを確認して下さい。
5.  チップ部品交換時の注意
 
・ 取外した部品は再使用しないで下さい。
 
・ タンタルコンデンサのマイナス側は熱に弱いため交
換時は注意して下さい。
6.  フレキシブルプリント基板の取扱いについて
 
・ コテ先温度を270℃前後にして行なって下さい。
 
・ 同一パターンに何度もコテ先を当てないで下さい。
(3回以内)
 
・ パターンに力が加わらないよう注意して下さい。
サービス,点検時には次のことにご注意ください。
無鉛半田について
本機には無鉛半田が使用されています。
無鉛半田を使用している基板には,無鉛(Lead Free)を意味
するレッドフリーマークがプリントされています。
(注意:  基板サイズによっては,無鉛半田を使用していて
もレッドフリーマークがプリントされていないも
のがあります)
:レッドフリーマーク
無鉛半田には,以下の特性があります。
・   融点が従来の半田よりも約40℃高い。
従来の半田こてをそのまま使用することは可能ですが,
少し長めにこてを当てる必要があります。温度調節機能
のついた半田こてを使用する場合,約350℃に設定して
下さい。
注意:半田こてを長く当てすぎると,基板のパターン(銅
箔)がはがれてしまうことがありますので,注意
して下さい。
・   粘性が強い
従来の半田よりも粘性が強いため,IC端子などが半田ブ
リッジしないように注意して下さい。
・   従来の半田と混ぜて使用可能
無鉛半田には無鉛半田を追加するのが最適ですが,従来
の半田を追加しても構いません。
– ENGLISH –
– JAPANESE –
1-1
DCR-SX73E/SX83/SX83E, HDR-CX110/CX110E/CX115E/CX116E/CX150/CX150E/CX155E/CX170_L2
1. SERVICE  NOTE
– ENGLISH –
1-3-3. Self-diagnosis Code Table
Self-diagnosis Code
Symptom/State
Correction
Repaired by:
Block
Function
Detailed
Code
C
0
4
0
0
Non-standard battery is used.
Use the InfoLITHIUM battery.
C
0
6
0
0
The battery pack temperature is high.
Change the battery pack or place it in a cool place.
C
1
3
0
1
Memory card is unformatted.
Memory card is broken.
Format the memory card.
Insert a new memory card.
C
1
3
0
2
Disc access error
HDR-CX116E/CX150/CX150E/CX155E
,
 DCR-SX73E/
SX83/SX83E
Remove the power source. Reconnect it again and operate 
your camcorder again.
E
2
0
0
0
Flash memory data are rewritten.
Make flash memory data correct value. (Note)
E
6
1
0
0
Difficult to adjust focus
(Cannot initialize focus)
In case zooming is performed by the touch panel operation,
inspect the focus reset sensor (pin
 
1 to 4 , qk
 of CN1003 
on the  VC-590 board). 
In case zooming is not performed, inspect the focus motor  
drive circuit (IC5306 on the VC-590 board). 
E
6
1
1
0
Zoom operations fault
(Cannot initialize zoom lens.)
Inspect the lens block zoom MR sensor (pin 
qf, wa to wf
 of 
CN1003 on the VC-590 board) when zooming is performed 
when the zoom lever is operated, or the zoom motor drive 
circuit (IC5306 on the VC-590 board) when zooming is not 
performed.
E
6
1
1
1
The abnormalities in initialization of 
the focus lens and the abnormalities 
in initialization of the zoom lens oc-
curred simultaneously.
Check both 
E
: 61: 00 and E: 61: 10 of the self-diagnosis 
code.
E
6
2
0
0
Handshake correction function does 
not work well. (With PITCH angular 
velocity sensor output stopped.)
Inspect PITCH angular velocity sensors (SE6602 on the MS-
431 board) peripheral circuits.
E
6
2
0
1
Handshake correction function does 
not work well. (With YAW angular 
velocity sensor output stopped.)
Inspect YAW angular velocity sensors (SE6603 on the MS-
431 board) peripheral circuits.
E
9
2
0
1
Battery current value goes over the 
max discharge current
Check the remaining battery power because this symptom 
maybe depended on the remaining battery level, and confirm 
whether or not the symptom is occurred after replacing the 
battery.
If the symptom is still occurred, overhaul inspection is 
needed.
Connect MS-431 board to VC-590 board via FP-1185 (VC-
MS) flexible board and connect DC/BATT harness to VC-
590 board (this is the minimum connection to periphery).
in the above state, check each output of DC/DC converter 
(IC4701).
E
9
4
0
0
Fault of writing or erasing the flash 
memory
Inspect the flash memory (IC8101 on the VC-590 board).
E
9
4
0
1
Internal flash memory fault
EXCEPT HDR-CX110/
CX110E
/CX115E
Inspect the flash memory (IC8701 on the JK-395 board).
E
9
4
0
2
BGM data error
Inspect the flash memory (IC8701 on the JK-395 board). If it 
is OK, check the CPU (IC7501 on the VC-590 board).
Note:  Start the Adjust Manual in the Adjust Station and refer to the “Destination data write”.
1-1.  POWER SUPPLY DURING REPAIRS
In this unit, about 10 seconds after power is supplied to the battery terminal using the regulated power supply (8.4 V), the power is shut off 
so
 that the unit cannot operate.
These following method is available to prevent this.
Method:
Use the genuine AC power adaptor
1-2.  PRECAUTION ON REPLACING THE VC-590 BOARD
Turn on the set and establish a USB connection , save the USB serial data before replacing the board.
DESTINATION DATA
When you replace to the repairing board, the written destination data of repairing board also might be changed to original setting.
Start the Adjust Manual in the Adjust Station and execute the “DESTINATON DATA WRITE”.
After the board replacement, the error of the built-in recording media may be displayed.
in this case, execute the [DESTINATION DATA WRITE] then the error will be cleared.
If it is not cleared with [DESTINATION DATA WRITE], format the built-in recording media.
USB SERIAL SAVE
When you replace to the repairing board, get the data from the former one.
Start the Adjust Manual in the Adjust Station and perform “USB SERIAL SAVE” to get the data.
USB SERIAL No.
The set is shipped with a unique ID (USB Serial No.) written in it.
This ID has not been written in a new board for service, and therefore it must be entered after the board replacement.
Start the Adjust Manual in the Adjust Station and execute the “USB SERIAL No. INPUT”.
1-3. SELF-DIAGNOSIS FUNCTION
1-3-1. Self-diagnosis Function
When problems occur while the unit is operating, the self-diagnosis function starts working, and displays on the LCD screen what to do.
Details of the self-diagnosis functions are provided in the Instruction manual.
1-3-2. Self-diagnosis Display
When problems occur while the unit is operating, the counter of the LCD screen shows a 4-digit display consisting of an alphabet and 
numbers, which blinks at 3.2 Hz. This 5-character display indicates the “repaired by:”, “block” in which the problem occurred, and “detailed 
code” of the problem.
1 1
3 1
C
Repaired by:
Refer to “1-3-3. Self-diagnosis Code Table” .
Indicates the appropriate
step to be taken.
E.g.
31 ....Reload the tape.
32 ....Turn on power again.
Block
Detailed Code
Blinks at 3.2Hz
C : Corrected by customer
H : Corrected by dealer
E : Corrected by service
engineer
LCD screen
C : 3 1 : 1 1
The changed portions from
Ver. 1.0 are shown in blue.
Ver. 1.1 2010.02
DCR-SX73E/SX83/SX83E, HDR-CX110/CX110E/CX115E/CX116E/CX150/CX150E/CX155E/CX170_L2
1-2E
1-1.   修理時の電源供給について
本機では,安定化電源(8.4Vdc)からバッテリ端子に電源を供給した場合,約10秒後にシャットオフし,動作しなくなります。
これを避けるため,下記の方法を用いてください。
方法:
ACアダプタを使用する。
1-2.  VC-590基板交換時の注意
基板交換時は下記の仕向書き込みとUSB SERIAL SAVEが必要です。
仕向けデータ
補修用基板と交換する時,補修用基板に書かれている仕向けデータは元の設定と違っている場合があります。
Adjust StationからAdjust Manualを起動させて「Destination data write」を実行させてください。
基板を交換した後,内蔵メモリーのエラーがディスプレイに表示される事があります。
この場合は,[DESTINATION DATA WRITE] を実行することでエラーが解消されます。
エラーが解消されない場合は,[DESTINATION DATA WRITE] と共に内蔵メモリーをフォーマットしてください。
USBシリアルセーブ
補修用基板と交換する時,交換前の基板よりUSBシリアルNo.を取得してください。
データの取得はAdjust StationからAdjust Manualを起動させて「USB SERIAL SAVE」を実行させてください。
USBシリアルNo.
セットは,1台毎に異なる固有のID(USB Serial No.)を書き込んだ後,出荷されています。
新品の補修用基板には,このIDが書き込まれていないので,基板交換後にIDを入力する必要があります。
Adjust StationからAdjust Manualを起動させて「USB serial No. input」を実行させてください。
1-3.  自己診断機能
1-3-1. 自己診断機能について
本機の動作に不具合が生じたとき,自己診断機能が働き,ビューファインダまたはLCD画面に,どう処置したらよいか判断
できる表示を行います。「自己診断表示」と「サービスモード表示」の2つの表示があります。自己診断機能については取扱説
明書にも掲載されています。
1-3-2. 自己診断表示
本機の動作に不具合が生じたとき,LCD画面のカウンタ表示部分がアルファベットと数字の4桁表示になり,3.2Hzで点滅し
ます。この5 文字の表示によって対応者分類および不具合の生じたブロックの分類,不具合の詳細コードを示します。
1-3-3. 自己診断コード表
シート 自己診断表(J) より表を挿入
1 1
C
1
3
対応者分類
「1-3-3.自己診断コード表」
を参照
対応方法の違いにより分類
例 31・・・テープを入れ直す
32・・・電源を入れ直す
ブロック分類
詳細コード
3.2Hz点滅
C:お客さま自身で対応
H:販売店で対応
E:サービスエンジニア
で対応
LCD画面
C : 3 1 : 1 1
1 1
C
1
3
対応者分類
「1-3-3.自己診断コード表」
を参照
対応方法の違いにより分類
例 31・・・テープを入れ直す
32・・・電源を入れ直す
ブロック分類
詳細コード
3.2Hz点滅
C:お客さま自身で対応
H:販売店で対応
E:サービスエンジニア
で対応
LCD画面
C : 3 1 : 1 1
– JAPANESE –
1-3-3. 
自己診断コード表
自己診断コード
症状/状態
対応/方法


ブロック
機能
詳細
コード
C
0   4
0   0
標準でないバッテリを使用している
インフォリチウムバッテリを使用する。
C
0   6
0   0
バッテリが高温になっている
バッテリを交換するか、バッテリを涼しいところに置
く。
C
1   3
0   1
フォーマットしていないメモリー
カードを入れた
メモリーカードが壊れている
メモリーカードをフォーマットする。
新しいメモリーカードに交換する。
C
1   3
0   2
アクセスエラー
電源を外し,再度入れ直してから操作する。
E
2   0
0   0
フラッシュメモリが書き換えられて
いる
フラッシュメモリのデータを元の値に戻す。(注意)
E
6   1
0   0
フォーカスが合いにくい
(フォーカスの初期化ができない)
タッチパネルでフォーカス操作をしたときにフォーカ
ス動作をすれば,レンズブロックのフォーカスリセッ
トセンサ(VC-590基板CN1003 
1 ∼ 4, qk
ピン)を点
検する。フォーカス動作をしなければフォーカスモー
タ駆動回路(VC-590基板IC5306)を点検する。
E
6   1
1   0
ズーム動作の異常(ズームレンズの
初期化ができない)
ズームレバーを操作したときにズーム動作をすれ
ば,レンズブロックのズームMRセンサ(VC-590基板
CN1003 
qf, wa ∼ wf
ピン)を点検する。
ズーム動作をしなければズームモータ駆動回路
(VC-590基板IC5306)を点検する。
E
6   1
1   1
フォーカスレンズ初期化異常,ズー
ムレンズ初期化異常の同時発生
自己診断コード
E:61:00
とE:61:10の両方を点検
する。
E
6   2
0   0
手振れ補正が効きにくい
(PITCH角速度センサ出力張り付き)
PITCH角速度センサ(MS-431基板SE6602)周辺回路を
点検。
E
6   2
0   1
手振れ補正が効きにくい
(YAW角速度センサ出力張り付き)
YAW角速度センサ(MS-431基板SE6603)周辺回路を点
検。
E
9   2
0   1
(バッテリーの)電流値が最大放電電
流を超えた
バッテリ残量に依存する場合があるので,バッテリ残
量を確認する。
次にバッテリを交換して症状が出るか確認する。
バッテリを交換しても症状が出る場合は,エラー発
生後に電源が切れてしまうため,分解して確認する,
VC-590基板にMS-431基板をFP-1185 (VC-MS) フレキ
シブル基板で接続し,DC/バッテリハーネスをVC-590
基板に接続した状態 (最小限の接続) でDC / DCコン
バータ (VC-590基板IC4701) の各チャンネル出力を確
認する。
E
9   4
0   0
フラッシュメモリの書込み/消去動
作不良
フラッシュメモリ(VC-590基板 IC8101)を点検する。
E
9   4
0   1
フラッシュメモリ内部異常
フラッシュメモリ(JK-395基板 IC8701)を点検する。
E
9   4
0   2
BGM データ異常
フラッシュメモリ(JK-395基板 IC8701)を点検する。
異常がない場合は,CPU(VC-590基板 IC7501)を点検
する。
注意:  Adjust StationからAdjust Manualを起動させて「DESTINATION DATA WRITE」を参照してください。
The changed portions from
Ver. 1.0 are shown in blue.
Ver. 1.1 2010.02
2-1
DCR-SX73E/SX83/SX83E, HDR-CX110/CX110E/CX115E/CX116E/CX150/CX150E/CX155E/CX170_L2
2. REPAIR  PARTS  LIST
Follow the disassembly in the numerical order given.
IDENTIFYING  PARTS
AC-
DIS-
Link
ACCESSORIES
ASSEMBLY
VC-590
BT Panel Section
 
[Disassembly]
 [Exploded 
View]
 • 
MS-431 
Board
 
• FP-1189 Flexible Board
Cabinet (R) Section
 
[Disassembly]
 [Exploded 
View]
 • 
LCD 
Section
 
  •  PD-404 Board
 
• Cabinet (R) Section
 
  • JK-395 Board
 
  • FP-1183 Flexible Board
 
  • FP-1191 Flexible Board
 
  • FP-1192 Flexible Board
         (CX116E/CX150/CX150E/CX155E/
          CX170/SX73E/SX83/SX83E)
Lens Section
 • 
CM-114 
Board
Cabinet (L) Section
Cabinet (F) Section
Cabinet BM Block
VC-590 Board
Cabinet T Section
(ENGLISH)
NOTE:
•  -XX, -X mean standardized parts, so they may have some 
differences from the original one.
•  Items marked “*” are not stocked since they are seldom re-
quired for routine service. Some delay should be anticipated 
when ordering these items.
•  The mechanical parts with no reference number in the exploded 
views are not supplied.
•  Due to standardization, replacements in the parts list may 
be different from the parts specified in the diagrams or the 
components used on the set.
(JAPANESE)
【使用上の注意】
•  ここに記載されている部品は,補修用部品であるため,回
路図及びセットに付いている部品と異なる場合があります。
•  -XX,-Xは標準化部品のため,セットに付いている部品と異
なる場合があります。
•  *印の部品は常備在庫しておりません。
•  Color Indication of Appearance Parts
 Example:
 
(SILVER) : Cabinet’s Color
 
(Silver) 
: Parts Color
•  外装部品色表示
 
例:
 
(SILVER) :セットの色を表す。
 
(Silver)  :部品の色を表す。
The components identified by mark  
or dotted line with mark  are critical 
for safety.
Replace only with part number specified.
Les composants identifiés par une 
marque  sont critiques pour la sécurité.
Ne les remplacer que par une pièce 
portant le numéro spécifié.
印の部品,または印付の点線で囲まれた部品は,
安全性を維持するために,重要な部品です。
従って交換時は,必ず指定の部品を使用してください。
• Abbreviation
 AUS : 
Australian 
model
  BR  
: Brazilian model
  CH  
: Chinese model
  CND   : Canadian model
  HK   : Hong Kong model
  KR  
: Korea model
  NE  
: North European model
Right View
Left View
Front View
Bottom View
Top View
Back View
View Position
Page of 28
Display

Click on the first or last page to see other DCR-SX73E / DCR-SX83 / DCR-SX83E / HDR-CX110 / HDR-CX110E / HDR-CX115E / HDR-CX116E / HDR-CX150 / HDR-CX150E / HDR-CX155E / HDR-CX170 (serv.man2) service manuals if exist.