DOWNLOAD Sony DCR-PC2E / DCR-PC3 / DCR-PC3E Service Manual ↓ Size: 34.78 MB | Pages: 127 in PDF or view online for FREE

Model
DCR-PC2E DCR-PC3 DCR-PC3E
Pages
127
Size
34.78 MB
Type
PDF
Document
Service Manual
Brand
Device
Movie / S/M DCR-PC2E/PC3/PC3E 99 CAN
File
dcr-pc2e-dcr-pc3-dcr-pc3e.pdf
Date

Sony DCR-PC2E / DCR-PC3 / DCR-PC3E Service Manual ▷ View online

5-43
6. APC & AEQ Adjustment (MR-41 board)
Mode
Camera record and playback
Subject
Arbitrary
Measurement Point
Pin @º of CN2904 (RF MON) on
VC-220 board (Note 1)
External trigger: Pin !¶ of CN2904
(SWP)
Measuring Instrument
Oscilloscope
Adjustment Page
C
Adjustment Address
18, 19, 1B, 1C, 21, 73
Specified Value
The display data of page: 3,
address: 03 is “00”
Note 1:
Connect a 75
 resistor between Pin @º and Pin !ª (GND) of
CN2904.
75
 resistor (Parts code: 1-247-804-11)
Note 2:
The “5. AGC Center Level Adjustment” must have already been
completed before starting this adjustment.
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 2, address: 30, and set data: 40.
3)
Record the camera signal for a minute.
4)
Playback the recorded segment.
5)
Select page: 3, address: 33, and set data: 08.
6)
Check that the playback RF signal is stable.
7)
Select page: 3, address: 01, set data: 07, and press the PAUSE
button of the adjustment remote commander.
8)
Select page: 3, address: 02, and check that the data changes
from “07” to “00” in about 15 seconds after pressing the PAUSE
button.
9)
Select page: 3, address: 03, and check that the data is “00”.
Note:
If the data of page: 3, address: 03 is other than “00”, adjustment
has errors. (Take an appropriate remedial measures according
to the errors referring to the following table. )
10) Select page: 3, address: 33, and set data: 00.
11) Select page: 2, address: 30, and set data: 00.
12) Select page: 0, address: 01, and set data: 00.
Note 3:
If this data is displayed twice successively, the machine is defective.
(Note4)
Note 4:
Select page: C, address: 24, and change the data from “0F” to
“0D” or “0E”, and perform re-adjustment. If this data of page: 3,
address: 03 is “00” at step.9), the machine is not defective.
Data of page: 3,
address: 03
20
30
50
60
80
Contents of defect
Perform re-adjustment. (Note 3)
The machine is defective. (Note4)
Perform re-adjustment. (Note 3)
The machine is defective. (Note4)
The machine is defective. (Note4)
7. PLL f
0
 & LPF f
0
 Final Adjustment (MR-41 board)
Mode
VTR playback
Signal
Arbitrary
Measurement Point
Display data of page: 3, address: 03
Measuring Instrument
Adjustment remote commander
Adjustment Page
C
Adjustment Address
1F, 20, 22, 47
Specified Value
00
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 3, address: 01, set data: 30, and press the PAUSE
button of the adjustment remote commander.
3)
Select page: 3, address: 02, and check that the data changes to
“00”.
4)
Select page: 3, address: 03, and check that the data is “00”.
Note:
If the data of page: 3, address: 03 is other than “00”, there are
errors. (For the error contents, see the following table. For the
bit values, refer to “5-4. SERVICE MODE”, “4-3. 3. Bit value
discrimination”. )
5)
Select page: 0, address: 01, and set data: 00.
Bit value of page: 3,
Error contents
address: 03
bit 4 = 1
PLL f
0
, even channel is defective
bit 5 = 1
PLL f
0
, odd channel is defective
bit 6 = 1
LPF f
0
 is defective
bit 3 = 1
PLL f
0
 final adjustment is defective
Pin 
Pin 
PB RF signal is stable
6.7 msec
Fig. 5-3-7.
5-44
3-4.  VIDEO SYSTEM ADJUSTMENTS
Before perform the video system adjustments, check that the
specified value of “36 MHz Origin Oscillation Adjustment” of
“CAMERA SYSTEM ADJUSTMENT” is satisfied.
3-4-1. Base Band Block Adjustments
1. Chroma BPF f
0
 Adjustment (VC-220 board)
Set the center frequency of IC1402 chroma band-pass filter.
Mode
VTR stop
Signal
No signal
Measurement Point
CH1: Chroma signal terminal of
S VIDEO jack (75 
 terminated)
CH2: Y signal terminal of S VIDEO
jack (75 
 terminated)
Measuring Instrument
Oscilloscope
Adjustment Page
C
Adjustment Address
2B
Specified Value
A = 100mVp-p or less
B = 200mVp-p or more
Switch setting:
DISPLAY (Menu setting) ............................. V-OUT/LCD
DISPLAY (FK-4750 block) ......................................... ON
Adjusting method:
1)
Check that the burst signal (B) is output to the chroma signal
terminal of S VIDEO jack.
2)
Select page: 0, address: 01, and set data: 01.
3)
Select page: 3, address: 0C, set data: 04, and press the PAUSE
button of the adjustment remote commander.
4)
Select page: C, address: 2B, and change the data for minimum
amplitude of the burst signal level (A).
(The data of address: 2B, should be “00” to “07”.)
5)
Press the PAUSE button of the adjustment remote commander.
6)
Select page: 3, address: 0C, set data: 00, and press the PAUSE
button of the adjustment remote commander.
6)
Check that the burst signal level (B) is satisfied the specified
value.
7)
Select page: 0, address: 01, and set data: 00.
2. S VIDEO OUT Y Level Adjustment (VC-220 board)
Mode
Camera
Subject
Arbitrary
Measurement Point
Y signal terminal of S VIDEO jack
(75 
 terminated)
Measuring Instrument
Oscilloscope
Adjustment Page
C
Adjustment Address
25
Specified Value
A = 1000 ± 14mV
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 2, address: 35. After note down the data of this
address, set data: 01 to the address.
3)
Select page: 3, address: 0C, set data: 02, and press the PAUSE
button of the adjustment remote commander.
4)
Select page: C, address: 25, change the data and set the Y signal
level (A) to the specified value.
5)
Press the PAUSE button of the adjustment remote commander.
6)
Select page: 3, address: 0C, set data: 00, and press the PAUSE
button of the adjustment remote commander.
7)
Select page: 2, address: 35. and set the data that is noted down
at step 2).
8)
Select page: 0, address: 01, and set data: 00.
Fig. 5-3-9.
CH1
CH2
A
H
H
CH1
B
Fig. 5-3-8.
H
Center of luminance line
A
When the data pf page: 3, address: 0C, is 04:
When the data pf page: 3, address: 0C, is 00:
5-45
3. S VIDEO OUT Chroma Level Adjustment
    (VC-220 board)
 Mode
Camera
Subject
Arbitrary
Measurement Point
Chroma signal terminal of S VIDEO
jack (75 
 terminated)
External trigger: Y signal terminal of
S VIDEO jack
Measuring Instrument
Oscilloscope
Adjustment Page
C
Adjustment Address
26, 27
Specified Value
Cr level:
A = 714 ± 14mV(NTSC)
A = 700 ± 14mV(PAL)
Cb level:
B = 714 ± 14mV(NTSC)
B = 700 ± 14mV(PAL)
Burst level: C = 286 ± 6mV(NTSC)
C = 300 ± 6mV(PAL)
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 2, address: 35. After note down the data of this
address, set data: 01 to the address.
3)
Select page: 3, address: 0C, set data: 02, and press the PAUSE
button of the adjustment remote commander.
4)
Select page: C, address: 26, change the data and set the Cr
signal level (A) to the specified value.
5)
Press the PAUSE button of the adjustment remote commander.
6)
Select page: C, address: 27, change the data and set the Cb
signal level (B) to the specified value.
7)
Press the PAUSE button of the adjustment remote commander.
8)
Check that the burst signal level (C) is satisfied the specified
value.
9)
Select page: 3, address: 0C, set data: 00, and press the PAUSE
button of the adjustment remote commander.
10) Select page: 2, address: 35. and set the data that is noted down
at step 2).
11) Select page: 0, address: 01, and set data: 00.
4. AV OUT Y, Chroma Level Check (VC-220 board)
Mode
Camera
Subject
Arbitrary
Measurement Point
Video terminal of AUDIO/VIDEO
jack (75 
 terminated)
Measuring Instrument
Oscilloscope
Specified Value
Sync level: A = 286 ± 18mV(NTSC)
A = 300 ± 18mV(PAL)
Burst level: B = 286 ± 18mV(NTSC)
B = 300 ± 18mV(PAL)
Adjusting method:
1)
Select page: 2, address: 35. After note down the data of this
address, set data: 01 to the address.
2)
Select page: 3, address: 0C, set data: 02, and press the PAUSE
button of the adjustment remote commander.
3)
Check that the sync signal level (A) satisfies the specified value.
4)
Check that the burst signal level (B) satisfies the specified value.
5)
Select page: 3, address: 0C, set data: 00, and press the PAUSE
button of the adjustment remote commander.
6)
Select page: 2, address: 35. and set the data that is noted down
at step 1).
Fig. 5-3-10.
Fig. 5-3-11.
H
C
A
0.28 
µ
sec (NTSC)
0.23 
µ
sec (PAL)
B
0.28 
µ
sec (NTSC) 
0.23 
µ
sec (PAL)
H
B
A
5-46
5. PLL Adjustment (VC-220 board)
    (Except AEP/UK model)
Set the VCO center level of the video input circuit (IC1200).
Mode
VTR stop
Signal
Color bar (Video terminal of AUDIO/
VIDEO jack input)
Measurement Point
Display data of page: 3, address: 04
Measuring Instrument
Adjustment remote commander
Adjustment Page
F
Adjustment Address
4D
Specified Value
08 or 09 (Note 1), 08 to 0A (Note 2)
Note 1:
When the data of page: F, address: 4D is “00” to “FE”.
Note 2:
When the data of page: F, address: 4D is “FF”.
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 3, address: 0C, set data: 80, and press the PAUSE
button of the adjustment remote commander.
3)
Select page: F, address: 4D, and set data: 00, and press the
PAUSE button.
4)
Select page: 3, address: 04, and check. If the data is “08” or
“09”, proceed to step 7).
5)
Select page: F, address: 4D, add “10”(hexadecimal) to the data
and press the PAUSE button.
Note 3:
If the data of page: F, address: 4D is “F0”, change the data to
“FF” and press the PAUSE button.
6)
Select page: 3, address: 04, and check the data satisfies the
specified value. If not repeat steps 5) to 6).
7)
Select page: 3, address: 0C, set data: 00, and press the PAUSE
button of the adjustment remote commander.
8)
Select page: 0, address: 01, and set data: 00.
Page of 127
Display

Sony DCR-PC2E / DCR-PC3 / DCR-PC3E Service Manual ▷ Download