DOWNLOAD Sony DCR-PC109 / DCR-PC109E (serv.man4) Service Manual ↓ Size: 1.17 MB | Pages: 65 in PDF or view online for FREE

Model
DCR-PC109 DCR-PC109E (serv.man4)
Pages
65
Size
1.17 MB
Type
PDF
Document
Service Manual
Brand
Device
Movie / SECTION 6 ADJUSTMENTS
File
dcr-pc109-dcr-pc109e-sm4.pdf
Date

Sony DCR-PC109 / DCR-PC109E (serv.man4) Service Manual ▷ View online

6-58
DCR-PC109/PC109E
Data (4 digits)
8. Switch check (4)
Page 7
Address F3
Note: The data of page: 0, address: 10 must be “00”.
Using method:
1)
Select page: 7, address: F3.
2)
By discriminating the bit value of display data, the state of the switch can be discriminated.
Bit
1
2
3
Function
Handycam station connector (CR-047 board CN801)
S VIDEO jack (Handycan station)
A/V jack (FP-843 flexible J002 or Handycam station)
When bit value=1
Used
Used
Used
When bit value=0
Not used
Not used
Not used
9. Switch check (5)
Page 7
Address F4
Note: The data of page: 0, address: 10 must be “00”.
Using method:
1)
Select page: 7, address: F4.
2)
By discriminating the bit value of display data, the state of the switch can be discriminated.
Bit
2
Function
MIC jack (SE-140 board J401)
When bit value=1
Used
When bit value=0
Not used
10. Switch check (6)
Page 7
Address 60 to 69
Note: The data of page: 0, address: 10 must be “00”.
Using method:
1)
Select page: 7, address: 60 to 69.
2)
By discriminating the display data, the pressed key can be discriminated.
Example: If the data of address: 60 is “00” and the data of address: 61 is “02”, the data of KEY AD0 signal is “0002”. It can be
discriminated that the START/STOP button is pressed.
Address
60 (Upper digits)
61 (Lower digits)
(KEY AD0)
(IC8401 <zc.>)
62 (Upper digits)
63 (Lower digits)
(KEY AD1)
(IC8401 <zv/>>)
64 (Upper digits)
65 (Lower digits)
(KEY AD2)
(IC8401 <zvz>>)
66 (Upper digits)
67 (Lower digits)
(KEY AD3)
(IC8401 <zvx>>)
68 (Upper digits)
69 (Lower digits)
(KEY AD4)
(IC8401  <zvc>)
0000
(0000 to 0033)
REC START/STOP
(SS6800 block)
(S002)
REC START/STOP
(SB6300 block)
(S001)
PHOTO
(PHOTO REC)
(ZM6800 block)
(S002)
EASY
(CR-047 board)
(S801)
PANEL REVERSE
(FP-926 flexible)
(S101)
006C
(0034 to 009B)
PANEL CLOSE
(FP-847 flexible)
(S001)
00D4
(009C to 010F)
LCD BACK LIGHT
ON/OFF
(SB6300 block)
(S002)
033C
(02DC to 039B)
BACK LIGHT
(SS6800 block)
(S003)
03FC
(039C to 03FF)
No key input
No key input
No key input
PANEL OPEN
(FP-847 flexible)
(S001)
PANEL NORMAL
(FP-926 flexible)
(S101)
014C
(0110 to 019B)
PHOTO
(PHOTO FREEZE)
(ZM6800 block)
(S001)
6-59
DCR-PC109/PC109E
11. LED check
Page 7
Address 00, 01, 04
Note:
The data of page: 0, address: 10 must be “00”.
Using method:
1)
Select page: 7, address: 01, and set data: 90.
2)
Select page: 7, address: 04, and set data: 01.
3)
Select page: 7, address: 00, set data: 01 and press the PAUSE button.
4)
Check that the following LEDs are lit.
TALLY, CHARGE, CAMERA-TAPE, CAMERA-MEMORY, PLAY/EDIT, MEMORY STICK, NIGHT SHOT light,
EASY OPERATION
5)
Select page: 7, address: 01, and set data: 90.
6)
Select page: 7, address: 04, and set data: 00.
7)
Select page: 7, address: 00, set data: 01 and press the PAUSE button.
8)
Select page: 7, address: 00, and set data: 00.
9)
Select page: 7, address: 01, and set data: 00.
12. Record of Use check (1)
Page 7
Address A7 to A9
Note1: When replacing the drum assembly or the mechanism deck, initialize the data of address: A7 to A9.
Note2: This data will be kept even if the lithium battery (MS-201 board BT501) is removed.
Note3: The data of page: 0, address: 10 must be “00”.
Address
A7
A8
A9
Function
Drum rotation
Hour (H)
counted time
Hour (M)
(BCD code)
Hour (L)
Remarks
100000th place digit and 10000th place digit of counted time
1000th place digit and 100th place digit of counted time
10th place digit and 1st place digit of counted time
Using method:
1)
The record of use data is displayed at addresses: A7 to A9.
Initializing method:
1)
Select page: 7, address: A7, set data: 00 and press the PAUSE button.
2)
Select page: 7, address: A8, set data: 00 and press the PAUSE button.
3)
Select page: 7, address: A9, set data: 00 and press the PAUSE button.
13. Record of Use check (2)
Page 7
Address C8 to CD
Note1: This data will be kept even if the lithium battery (MS-201 board BT501) is removed.
Note2: The data of page: 0, address: 10 must be “00”.
Using method:
1)
The record of use data is displayed at addresses: C8 to CD.
Address
C8
C9
CA
CB
CC
CD
Function
User initial power
Year
on date
Month
(BCD code)
Day
Final condensation
Year
occurrence data
Month
(BCD code)
Day
Remarks
After setting the clock, set the date of power on next
6-60
DCR-PC109/PC109E
14. Record of Self-diagnosis check
Page 7
Address B0 to C6
Note1: This data will be kept even if the lithium battery (MS-201 board
BT501) is removed.
Note2: The data of page: 0, address: 10 must be “00”.
Address
Self-diagnosis code
B0
“Repaired by” code (Occurred 1st time)   *1
B1
“Block function” code (Occurred 1st time)
B2
“Detailed” code (Occurred 1st time)
B4
“Repaired by” code (Occurred 2nd time)   *1
B5
“Block function” code (Occurred 2nd time)
B6
“Detailed” code (Occurred 2nd time)
B8
“Repaired by” code (Occurred 3rd time)   *1
B9
“Block function” code (Occurred 3rd time)
BA
“Detailed” code (Occurred 3rd time)
BC
“Repaired by” code (Occurred 4th time)   *1
BD
“Block function” code (Occurred 4th time)
BE
“Detailed” code (Occurred 4th time)
C0
“Repaired by” code (Occurred 5th time)   *1
C1
“Block function” code (Occurred 5th time)
C2
“Detailed” code (Occurred 5th time)
C4
“Repaired by” code (Occurred the last time)   *1
C5
“Block function” code (Occurred the last time)
C6
“Detailed” code (Occurred the last time)
*1: “01” 
t “C”, “03” t “E”
Using method:
1)
The past self-diagnosis codes are displayed at addresses: BC to C6. Refer to the following table.
Initializing method:
1)
Select page: 7, address: 01, and set data: C0.
2)
Select page: 7, address: 00, set data: 01 and press the PAUSE button.
3)
Check that the data of page: 7, address: B0 to C7 are “00”.
4)
Select page: 7, address: 00, and set data: 00.
5)
Select page: 7, address: 01, and set data: 00.
Take a copy of CAMERA COLOR
REPRODUCTION FRAME with
a clear sheet for use.
FOR CAMERA COLOR REPRODUCTION ADJUSTMENT
DCR-PC109
For NTSC model
For PAL model
DCR-PC109E
DCR-PC109/PC109E
6-61E
Page of 65
Display

Click on the first or last page to see other DCR-PC109 / DCR-PC109E (serv.man4) service manuals if exist.