Sony DCR-HC94E / DCR-HC96 / DCR-HC96E (serv.man4) Service Manual ▷ View online

6-8
DCR-HC94E/HC96/HC96E_ADJ
4.
Preparing the Flash Adjustment Box
A dark room is required to provide an accurate flash adjustment.
If it is not available, prepare the flash adjustment box as given
below;
1) Provide woody board A, B and C of 15 mm thickness.
2) Apply black mat paint to one side of woody board A and B.
3) Attach background paper (J-2501-130-A) to woody board C.
4) Assemble so that the black sides and the background paper
side of woody board A, B and C are internal. (Fig. 6-1-7)
Fig. 6-1-6
Fig. 6-1-7
woody board A (2)
400 mm
woody board B (2)
370 mm
woody board C (1)
700 mm
513 mm
513 mm
700 mm
700 mm
730 mm
woody board A
woody board B
woody board B
woody board C
woody board A
6-9
DCR-HC94E/HC96/HC96E_ADJ
1-2.
INITIALIZATION  OF  8,  A,  B,  C,  D,  E,  F,  14,
18,  19,  1A,  1B,  1C,  1E,  1F  PAGE  DATA
Note: If reading/writing data on pages 14, 18, 19, 1A, 1B, 1C,
1E, 1F, set data: 01 to page: 0, address: 10, and then select
pages: 4, 8, 9, A, B, C, E, F.
By this data setting, the pages 14, 18, 19, 1A, 1B, 1C, 1E,
1F, can be selected.
After the data reading/writing finished, return the data on
page: 0, address: 10 to “00”.
1-2-1.
Initialization of A, B, D, 1A, 1B Page Data
Note: Check that the data of page: 0, address: 10 is “00”.
1.
Initializing of A, B, D, 1A, 1B Page Data
Note 1: If the A, B, D, 1A, 1B page data has been initialized, the
following adjustments need to be performed again.
1) Modification of A, B, D, 1A, 1B page data
2) Touch panel adjustment
Adjustment Page
A
Adjustment Address
10 to FF
Adjustment Page
B
Adjustment Address
00 to FF
Adjustment Page
D
Adjustment Address
10 to 7F
Adjustment Page
1A
Adjustment Address
00 to FF
Adjustment Page
1B
Adjustment Address
00 to FF
Initializing method:
Order Page Address Data
Procedure
1
0
01
01
2
0
10
00
3
7
04
Set the following data
40: NTSC model
41: PAL model
Set the following data
20: Initializing A page
21: Initializing B page
22: Initializing D page
23: Initializing 1A page
24: Initializing 1B page
4
7
01
25: Initializing A and 1A
page
26: Initializing B and 1B
page
28: Initializing A, B, D, 1A
and 1B page
5
7
00
01
Press PAUSE (Write) button.
6
7
02
Check the data changes to
“01”.
7
Perform “Modification of A,
B, D, 1A, 1B Page Data”
Note 2: NTSC model: DCR-HC96
PAL model: DCR-HC94E/HC96E
2.
Modification of A, B, D, 1A, 1B Page Data
If the A, B, D, 1A, 1B page data has been initialized, change the
data of the “Fixed data-2” address shown in the following table by
manual input.
Modifying Method:
1) Before changing the data, select page: 0, address: 01, and set
data: 01.
2) If modification of data on pages A, B, D, set data: 00 to page:
0, address: 10, and then select pages A, B, D.
3) If modification of data on pages 1A, 1B, set data: 01 to page:
0, address: 10, and then select pages A, B.
After the modification of data finished, return the data on page:
0, address: 10 to “00”.
4) New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note 1: If copy the data built in the different model, the
camcorder may not operate.
5) When changing the data, press the PAUSE (Write) button of
the adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
6) Check that the data of adjustment addresses is the initial value.
If not, change the data to the initial value.
Processing after Completing Modification A, B, D, 1A, 1B
page data:
Order Page Address Data
Procedure
1
0
10
00
2
2
00
29
3
2
01
29
Press PAUSE (Write) button.
Note 2: If following symptoms occur after completing of the
“Modification A, B, D, 1A, 1B page data”, check that
the data of the “Fixed data-2” address of A, B, D, 1A, 1B
page are same as those of same model of same destina-
tion.
1) The power is shut off so that unit cannot operate.
6-10
DCR-HC94E/HC96/HC96E_ADJ
3.
A Page table
Note 1: Check that the data of page: 0, address: 10 is“00”.
Note 2: Fixed data-1: Initialized data. (Refer to“1. Initializing the
A, B, D, 1A, 1B Page Data”)
Fixed data-2: Modified data. (Refer to“2. Modification
of A, B, D, 1A, 1B Page Data”)
Address
Initial value
Remark
NTSC PAL
10
00
00
Test mode
11 to 16
Fixed data-1 (Initialized data)
17
18
Fixed data-2
19
Fixed data-1 (Initialized data)
1A
Fixed data-2
1B to 2E
Fixed data-1 (Initialized data)
2F
Fixed data-2
30
Fixed data-1 (Initialized data)
31
32
Fixed data-2
33 to 4F
Fixed data-1 (Initialized data)
50
Fixed data-2
51 to 5F
Fixed data-1 (Initialized data)
60
61
62
Fixed data-2
63
64 to 8F
Fixed data-1 (Initialized data)
90
E6
E8
91
10
0E
92
D5
CB
Touch panel adj.
93
23
31
94 to CF
Fixed data-1 (Initialized data)
D0
D1
Fixed data-2
D2
D3, D4
Fixed data-1 (Initialized data)
D5
Fixed data-2
D6
Fixed data-1 (Initialized data)
D7
Fixed data-2
D8
Fixed data-1 (Initialized data)
D9
Fixed data-2
DA to EF
Fixed data-1 (Initialized data)
F0
F1
Fixed data-2
F2
F3 to FF
Fixed data-1 (Initialized data)
4.
B Page table
Note 1: Check that the data of page: 0, address: 10 is “00”.
Note 2: Fixed data-1: Initialized data. (Refer to “1. Initializing
the A, B, D, 1A, 1B Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of A, B, D, 1A, 1B Page Data”)
Address
Initial value
Remark
NTSC PAL
00 to FF
Fixed data-1 (Initialized data)
6-11
DCR-HC94E/HC96/HC96E_ADJ
6.
1A Page table
Note 1: If reading/writing data on pages 1A, set data: 01 to page:
0, address: 10, and then select pages: A. By this data set-
ting, the pages 1A can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 2: Fixed data-1: Initialized data. (Refer to “1. Initializing
the A, B, D, 1A, 1B Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of A, B, D, 1A, 1B Page Data”)
Address
Initial value
Remark
NTSC PAL
00 to FF
Fixed data-1 (Initialized data)
7.
1B Page table
Note 1: If reading/writing data on pages 1B, set data: 01 to page:
0, address: 10, and then select pages: B. By this data set-
ting, the pages 1B can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 2: Fixed data-1: Initialized data. (Refer to “1. Initializing
the A, B, D, 1A, 1B Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of A, B, D, 1A, 1B Page Data”)
Address
Initial value
Remark
NTSC PAL
00 to FA
Fixed data-1 (Initialized data)
FB
Fixed data-2
FC
Fixed data-1 (Initialized data)
FD
Fixed data-2
FE, FF
Fixed data-1 (Initialized data)
5.
D Page table
Note 1: Check that the data of page: 0, address: 10 is “00”.
Note 2: Fixed data-1: Initialized data. (Refer to “1. Initializing
the A, B, D, 1A, 1B Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of A, B, D, 1A, 1B Page Data”)
Address
Initial value
Remark
NTSC PAL
10 to 13
Fixed data-1 (Initialized data)
14
Fixed data-2
15
Fixed data-1 (Initialized data)
16
Fixed data-2
17 to 27
Fixed data-1 (Initialized data)
28
29
2A
2B
2C
Fixed data-2
2D
2E
2F
30
31, 32
Fixed data-1 (Initialized data)
33
34
Fixed data-2
35 to 48
Fixed data-1 (Initialized data)
49
4A
Fixed data-2
4B
Fixed data-1 (Initialized data)
4C
Fixed data-2
4D
Fixed data-1 (Initialized data)
4E
Fixed data-2
4F to 56
Fixed data-1 (Initialized data)
57
Fixed data-2
58 to 79
Fixed data-1 (Initialized data)
7A
Fixed data-2
7B to 7F
Fixed data-1 (Initialized data)
Ver. 1.3  2007.09
Page of 79
Display

Click on the first or last page to see other DCR-HC94E / DCR-HC96 / DCR-HC96E (serv.man4) service manuals if exist.