DOWNLOAD Sony DCR-HC94E / DCR-HC96 / DCR-HC96E (serv.man2) Service Manual ↓ Size: 7.55 MB | Pages: 72 in PDF or view online for FREE

Model
DCR-HC94E DCR-HC96 DCR-HC96E (serv.man2)
Pages
72
Size
7.55 MB
Type
PDF
Document
Service Manual
Brand
Device
Movie / LEVEL 2
File
dcr-hc94e-dcr-hc96-dcr-hc96e-sm2.pdf
Date

Sony DCR-HC94E / DCR-HC96 / DCR-HC96E (serv.man2) Service Manual ▷ View online

1-2
DCR-HC94E/HC96/HC96E_L2
ENGLISH
JAPANESE
ENGLISH
JAPANESE
1-5. SELF-DIAGNOSIS  FUNCTION
1-5-1. Self-diagnosis Function
When problems occur while the unit is operating, the self-diagnosis
function starts working, and displays on the viewfinder or LCD
screen what to do. This function consists of two display; self-
diagnosis display and service mode display.
Details of the self-diagnosis functions are provided in the Instruction
manual.
1-5-2. Self-diagnosis Display
When problems occur while the unit is operating, the counter of the
viewfinder or LCD screen shows a 4-digit display consisting of an
alphabet and numbers, which blinks at 3.2 Hz. This 5-character
display indicates the “repaired by:”, “block” in which the problem
occurred, and “detailed code” of the problem.
1 1
3 1
C
Repaired by:
Refer to “1-5-3. Self-diagnosis Code Table”.
Indicates the appropriate
step to be taken.
E.g.
31 ....Reload the tape.
32 ....Turn on power again.
Block
Detailed Code
Blinks at 3.2Hz
C : Corrected by customer
H : Corrected by dealer
E : Corrected by service
engineer
Viewfinder or LCD screen
C : 3 1 : 1 1
1-4. USING SERVICE JIG
Connect the CPC-15 jig connector (J-6082-564-A) and I/F unit for LANC control (J-6082-521 A) to the CN1014 of VC-419 board.
1
8
CN1014
VC-419 BOARD
(SIDE A)
CPC-15
(J-6082-564-A)
I/F unit for LANC control
(J-6082-521-A)
1-3
DCR-HC94E/HC96/HC96E_L2
ENGLISH
JAPANESE
ENGLISH
JAPANESE
1-5-3. Self-diagnosis Code Table
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
Block
Function
0
4
2
1
2
2
3
1
3
1
3
1
3
1
3
1
3
1
3
1
3
1
3
1
3
1
3
1
3
1
3
1
3
2
3
2
3
2
3
2
3
2
3
2
3
2
3
2
3
2
3
2
3
2
3
2
3
2
Detailed
Code
0
0
0
0
0
0
1
0
1
1
2
0
2
1
2
2
2
3
3
0
3
1
4
0
4
1
4
2
4
3
4
4
1
0
1
1
2
0
2
1
2
2
2
3
3
0
3
1
4
0
4
1
4
2
4
3
4
4
Symptom/State
Non-standard battery is used.
Condensation.
Video head is dirty.
LOAD direction. Loading does not
complete within specified time
UNLOAD direction. Loading does not
complete within specified time
T reel side tape slacking when unloading.
S reel side tape slacking when unloading.
T reel fault.
S reel fault.
FG fault when starting capstan.
FG fault during normal capstan operations.
FG fault when starting drum.
PG fault when starting drum.
FG fault during normal drum operations.
PG fault during normal drum operations.
Phase fault during normal drum operations.
LOAD direction loading motor time-
out.
UNLOAD direction loading motor
time-out.
T reel side tape slacking when
unloading.
S reel side tape slacking when
unloading.
T reel fault.
S reel fault.
FG fault when starting capstan.
FG fault during normal capstan
operations.
FG fault when starting drum.
PG fault when starting drum.
FG fault during normal drum
operations.
PG fault during normal drum
operations.
Phase fault during normal drum
operations.
Self-diagnosis Code
Repaired b
y:
Correction
Use the InfoLITHIUM battery.
Remove the cassette, and insert it again after one hour.
Clean with the optional cleaning cassette.
Load the tape again, and perform operations from the beginning.
Load the tape again, and perform operations from the beginning.
Load the tape again, and perform operations from the beginning.
Load the tape again, and perform operations from the beginning.
Load the tape again, and perform operations from the beginning.
Load the tape again, and perform operations from the beginning.
Load the tape again, and perform operations from the beginning.
Load the tape again, and perform operations from the beginning.
Load the tape again, and perform operations from the beginning.
Load the tape again, and perform operations from the beginning.
Load the tape again, and perform operations from the beginning.
Load the tape again, and perform operations from the beginning.
Load the tape again, and perform operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
1-4
DCR-HC94E/HC96/HC96E_L2
ENGLISH
JAPANESE
ENGLISH
JAPANESE
E
E
E
E
E
E
Block
Function
6
1
6
1
6
1
6
2
6
2
9
1
Detailed
Code
0
0
1
0
1
1
0
0
0
1
0
1
Symptom/State
Difficult to adjust focus
(Cannot initialize focus.)
Zoom operations fault
(Cannot initialize zoom lens.)
Focus lens initializing failure and zoom
lens initializing failure occur simulta-
neously.
Steadyshot function does not work well.
(With pitch angular velocity sensor output
stopped.)
Steadyshot function does not work well.
(With yaw angular velocity sensor output
stopped.)
Abnormality when flash is being charged.
Self-diagnosis Code
Repaired b
y:
Correction
Inspect the lens block focus MR sensor (Pin ql, wa of CN3801 of
VC-419 board) when focusing is performed when the touch panel is
operated in the focus manual mode and the focus motor drive circuit
(IC3801 of VC-419 board) when the focusing is not performed.
Inspect the lens block zoom MR sensor (Pin qh, qk of CN3801 of
VC-419 board) when zooming is performed when the zoom switch
is operated and the zoom motor drive circuit (IC3801 of VC-419
board) when zooming is not performed.
Inspect the flexible board for breakage or loose connection.
If not faulty, inspect the focus and zoom motor drive circuit (IC3801
of VC-419 board).
Inspect pitch angular velocity sensor (SE401 of SI-054 board)
peripheral circuits.
Inspect yaw angular velocity sensor (SE402 of SI-054 board)
peripheral circuits.
Checking of flash unit or replacement of flash unit. (Note)
1-6. PROCESS  AFTER  FIXING  FLASH  ERROR
When “FLASH error” (Self-diagnosis Code E:91:**) occurs, to prevent any abnormal situation caused by high voltage, setting of the flash is
changed automatically to disabling charge and flash setting.
After fixing, this setting needs to be deactivated. Connect the adjustment remote commander (RM-95 or NEW LANC JIG) and perform the
following process.
Order Page Address Data
Procedure
1
7
01
75
2
7
00
01
Press PAUSE (Write) button.
3
7
02
Check the data changes to “01”.
Note: After repair, be sure to perform “1-6. PROCESS AFTER FIXING FLASH ERROR”.
1-7. PRECAUTION  ON  REPLACING  THE  VC-419  BOARD
Exif Model Data Check
When you replace to the repairing board, the written data of repairing board also might be changed to original setting.
When the data has changed because of board replaceing etc, check the data setting (Exif Model Data) is right. If not, rewrite to the right value.
Exif Model Data
Writing Method:
1) Select page: 0, address: 01 and set data: 01.
2) Select page: C, address: D2 to D4, and set the Exif Model Data.
Note: To write in the non-volatile memory (EEPROM), press the PAUSE (Write) button each time to set the data.
3) Select page: 0, address: 01, and set data: 00.
Page
C
C
C
Data
DCR-HC94E
39
34
45
DCR-HC96
39
36
00
DCR-HC96E
39
36
45
Address
D2
D3
D4
1-5
DCR-HC94E/HC96/HC96E_L2
ENGLISH
JAPANESE
ENGLISH
JAPANESE
1. SERVICE NOTE
1-2. イジェクトしない時のカセット取出し方法(強制イジェクト)
1
2. DISASSEMBLYを参照し,メカデッキを外す。
2
カセコン組立を押さえながら,安定化電源より+4.5Vをローディングモータに加え,アンローディングさせる。
ローディングモータ
安定化電源(+4.5Vdc)
1-3. 強制電源ONモードの設定
調整リモコン(RM-95またはNEW LANC JIG)を使用して,電源を入れることが出来ます。
VTR操作は調整リモコンで行えます。
1-3-1. 強制カメラ電源ONモードの設定
1) ページ:0,アドレス:01にデータ:01をセット。
2) ページ:A,アドレス:10にデータ:01をセットしPAUSE(Write)ボタンを押す。
1-3-2. 強制VTR電源ONモードの設定
1) ページ:0,アドレス:01にデータ:01をセット。
2) ページ:A,アドレス:10にデータ:02をセットしPAUSE(Write)ボタンを押す。
1-3-3. 強制電源ONモードの解除
1) ページ:0,アドレス:01にデータ:01をセット。
2) ページ:A,アドレス:10にデータ:00をセットしPAUSE(Write)ボタンを押す。
3) ページ:0,アドレス:01にデータ:00をセット。
1-1. 修理時の電源供給について
本機では,安定化電源(8.4Vdc)からバッテリ端子に電源を供給した場合,約10秒後にシャットオフし,動作しなくなります。
これを避けるため,下記の方法を用いてください。
方法:
DC入力端子を使用する。(ACアダプタ(AC-L25A/L25Bなど)を使用する。)
Page of 72
Display

Click on the first or last page to see other DCR-HC94E / DCR-HC96 / DCR-HC96E (serv.man2) service manuals if exist.