DOWNLOAD Sony DCR-HC90 / DCR-HC90E (serv.man2) Service Manual ↓ Size: 9.17 MB | Pages: 72 in PDF or view online for FREE

Model
DCR-HC90 DCR-HC90E (serv.man2)
Pages
72
Size
9.17 MB
Type
PDF
Document
Service Manual
Brand
Device
Movie / LEVEL 2
File
dcr-hc90-dcr-hc90e-sm2.pdf
Date

Sony DCR-HC90 / DCR-HC90E (serv.man2) Service Manual ▷ View online

— 7 —
DCR-HC90/HC90E
5.
REPAIR PARTS LIST
5-1.
EXPLODED VIEWS ······················································ 5-3
5-1-1. OVERALL SECTION ····················································· 5-3
5-1-2. CABINET (R) SECTION ··············································· 5-4
5-1-3. LCD SECTION ······························································· 5-5
5-1-4. CABINET (UPPER) SECTION ······································ 5-6
5-1-5. LENS BLOCK SECTION ··············································· 5-7
5-1-6. CABINET (L) SECTION-1 ············································ 5-8
5-1-7. CABINET (L) SECTION-2 ············································ 5-9
5-1-8. OVERALL MECHANISM DECK SECTION ············· 5-10
5-1-9. LS/MECHANICAL CHASSIS BLOCK ASSEMBLY-1 · 5-11
5-1-10. LS/MECHANICAL CHASSIS BLOCK ASSEMBLY-2 ·· 5-12
Checking supplied accessories ················································ 5-13
5-2.
ELECTRICAL PARTS LIST ········································ 5-15
Electrical parts list of the CD-540, CK-145, IR-
055, LD-176 and VC-380 board are not shown.
Pages from 5-17 to 5-27 are not shown.
1-1
DCR-HC90/HC90E
Make sure that the flat cable and flexible board are not cracked of 
bent at the terminal.
Do not insert the cable insufficiently nor crookedly.
Cut and remove the part of gilt 
which comes off at the point.
(Take care that there are 
some pieces of gilt left inside)
When remove a connector, don't pull at wire of connector.
Be in danger of the snapping of a wire.
When installing a connector, don't press down at wire of connector.
Be in danger of the snapping of a wire.
1-1. SERVICE NOTE
1.
NOTE FOR REPAIR
ENGLISH
JAPANESE
ENGLISH
JAPANESE
1. SERVICE NOTE
1-2
DCR-HC90/HC90E
ENGLISH
JAPANESE
ENGLISH
JAPANESE
2.
POWER SUPPLY DURING REPAIRS
In this unit, about 10 seconds after power is supplied to the battery terminal using the regulated power supply (8.4V), the power is shut off so
that the unit cannot operate.
This following two methods are available to prevent this. Take note of which to use during repairs.
Method 1.
Use the AC power adaptor.
Method 2.
Connect the servicing remote commander RM-95 (J-6082-053-B) to the LANC jack, and set the commander switch to the “ADJ” side.
3.
TO TAKE OUT A CASSETTE WHEN NOT EJECT (FORCE EJECT)
1
Remove the front panel section.
2
Remove the cabinet (R) section.
3
Remove the cabinet (upper) block assembly.
4
Remove the lens section.
5
Remove the FP-064 flexible board and ST-114 board.
6
Remove the VC-380 board.
7
Remove the MD frame and mechanism deck.
8
Connect the mechanism and the VC-380 board by inserting the three flexible boards from the left except the one going to CN1008
(29P, 0.3mm).
9
Supply +4.5V from the DC power supply to the loading motor and unload with pressing the cassette compartment.
VC-380 board
DC power supply (+4.5Vdc)
Loading motor
CN1008
Connect the three flexible board, 
but not the flexible board going to CN1008.
1-3
DCR-HC90/HC90E
ENGLISH
JAPANESE
ENGLISH
JAPANESE
4.
DISCHARGING OF THE FLASHLIGHT POWER SUPPLY CAPACITOR
The power supply capacitor (ST-114 board C8404, 8405) of the flash are charged up to the maximum 300V potential.
There is a danger of electric shock by this high voltage when the capacitors are handled by hand. The electric shock is caused by the charged
voltage which is kept without discharging when the main power of the unit is simply turned off. Therefore, the remaining voltage must be
discharged as described below.
4-1.
PREPARING THE SHORT JIG
To preparing the short jig, a small clip is attached to each end of a resistor of 1k
/1W (1-215-869-11)
Wrap insulating tape fully around the reads of the resistor to prevent electric shock.
4-2.
DISCHARGING THE  CAPACITOR
1
Open the cabinet (G) assembly.
2
Remove the cabinet top.
3
Connect the CL8404 (Check land of discharge) on the ST-114 board and the MD frame by using the short jig for about 10 seconds.
1 k
 
/1 W
Wrap insulating tape
Shorting jig
(1k
 / 1w)
Capacitor
ST-114 
board
CL8404
(Check land of discharge)
MD frame
Page of 72
Display

Click on the first or last page to see other DCR-HC90 / DCR-HC90E (serv.man2) service manuals if exist.