DOWNLOAD Sony DCR-HC47E / DCR-HC48 / DCR-HC48E (serv.man4) Service Manual ↓ Size: 788.14 KB | Pages: 77 in PDF or view online for FREE

Model
DCR-HC47E DCR-HC48 DCR-HC48E (serv.man4)
Pages
77
Size
788.14 KB
Type
PDF
Document
Service Manual
Brand
Device
Movie / SECTION 6 ADJUSTMENTS
File
dcr-hc47e-dcr-hc48-dcr-hc48e-sm4.pdf
Date

Sony DCR-HC47E / DCR-HC48 / DCR-HC48E (serv.man4) Service Manual ▷ View online

6-71
DCR-HC47E/HC48/HC48E_ADJ
10. Record of Use Check (1)
Page 7
Address A4 to AF
Note 1: This data will not be erased (reset) when the lithium 3 V
power supply (CF-102 board BT901) is removed.
Note 2: When the drum was replaced, initialize the drum rota-
tion counted time.
Note 3: Check that the data of page: 0, address: 10 is “00”.
Using method:
1) The record of use data is displayed at page: 7, addresses: A4 to
AF.
Initializing method:
Order Page Address Data
Procedure
1
7
A4
00
Press PAUSE (Write) button.
2
7
A5
00
Press PAUSE (Write) button.
3
7
A6
00
Press PAUSE (Write) button.
4
7
A7
00
Press PAUSE (Write) button.
5
7
A8
00
Press PAUSE (Write) button.
6
7
A9
00
Press PAUSE (Write) button.
7
7
AA
00
Press PAUSE (Write) button.
8
7
AB
00
Press PAUSE (Write) button.
9
7
AC
00
Press PAUSE (Write) button.
10
7
AD
00
Press PAUSE (Write) button.
11
7
AE
00
Press PAUSE (Write) button.
12
7
AF
00
Press PAUSE (Write) button.
Address
A4
A5
A6
A7
A8
A9
AA
AB
AC
AD
AE
AF
Function
Power supplying
Hour (H)
time
Hour (M)
Hour (L)
(BCD code)
Minute
Drum rotation
Hour (H)
counted time
Hour (M)
Hour (L)
(BCD code)
Minute
Tape run time
Hour (H)
Hour (M)
Hour (L)
(BCD code)
Minute
Remarks
100000th place digit and 10000th place digit of counted time (decimal digit)
1000th place digit and 100th place digit of counted time (decimal digit)
10th place digit and 1st place digit of counted time (decimal digit)
100000th place digit and 10000th place digit of counted time (decimal digit)
1000th place digit and 100th place digit of counted time (decimal digit)
10th place digit and 1st place digit of counted time (decimal digit)
100000th place digit and 10000th place digit of counted time (decimal digit)
1000th place digit and 100th place digit of counted time (decimal digit)
10th place digit and 1st place digit of counted time (decimal digit)
6-72
DCR-HC47E/HC48/HC48E_ADJ
11.  Record of Use Check (2)
Page 7
Address 90 to 95
Note 1: This data will not be erased (reset) when the lithium 3 V
power supply (CF-102 board BT901) is removed.
Note 2: When the drum was replaced, initialize the drum rota-
tion counted time.
Note 3: Check that the data of page: 0, address: 10 is “00”.
Using method:
1) The record of use data is displayed at page: 7, addresses: 90 to
95.
Initializing method:
Order Page Address Data
Procedure
1
7
90
00
Press PAUSE (Write) button.
2
7
91
00
Press PAUSE (Write) button.
3
7
92
00
Press PAUSE (Write) button.
4
7
93
00
Press PAUSE (Write) button.
5
7
94
00
Press PAUSE (Write) button.
6
7
95
00
Press PAUSE (Write) button.
12. Record of Use Check (3)
Page 7
Address C8 to CD
Note 1: This data will not be erased (reset) when the lithium 3 V
power supply (CF-102 board BT901) is removed.
Note 2: Check that the data of page: 0, address 10 is “00”.
Using method:
1) The record of use data is displayed at page: 7, addresses: C8 to
CD.
Address
90
91
92
93
94
95
Function
Eject count with tape
Count (H)
Count (M)
(BCD code)
Count (L)
Eject count without
Count (H)
 tape
Count (M)
(BCD code)
Count (L)
Remarks
100000th place digit and 10000th place digit of Eject count (decimal digit)
1000th place digit and 100th place digit of Eject count (decimal digit)
10th place digit and 1st place digit of Eject count (decimal digit)
100000th place digit and 10000th place digit of Eject count (decimal digit)
1000th place digit and 100th place digit of Eject count (decimal digit)
10th place digit and 1st place digit of Eject count (decimal digit)
Address
C8
C9
CA
CB
CC
CD
Function
User initial power
Year
on date
Month
(BCD code)
Day
Final condensation
Year
occurrence date
Month
(BCD code)
Day
Remarks
After setting the clock, set the date of power on next
6-73
DCR-HC47E/HC48/HC48E_ADJ
13. Record of Self-diagnosis Check
Page 7
Address B0 to C6
Note 1: This data will not be erased (reset) when the lithium 3 V
power supply (CF-102 board BT901) is removed.
Note 2: Check that the data of page: 0, address 10 is “00”.
Address
Self-diagnosis code
B0
“Repaired by” code (Occurred 1st time)   *1
B1
“Block function” code (Occurred 1st time)
B2
“Detailed” code (Occurred 1st time)
B4
“Repaired by” code (Occurred 2nd time)   *1
B5
“Block function” code (Occurred 2nd time)
B6
“Detailed” code (Occurred 2nd time)
B8
“Repaired by” code (Occurred 3rd time)   *1
B9
“Block function” code (Occurred 3rd time)
BA
“Detailed” code (Occurred 3rd time)
BC
“Repaired by” code (Occurred 4th time)   *1
BD
“Block function” code (Occurred 4th time)
BE
“Detailed” code (Occurred 4th time)
C0
“Repaired by” code (Occurred 5th time)   *1
C1
“Block function” code (Occurred 5th time)
C2
“Detailed” code (Occurred 5th time)
C4
“Repaired by” code (Occurred the last time)   *1
C5
“Block function” code (Occurred the last time)
C6
“Detailed” code (Occurred the last time)
*1 : “01” 
t “C”, “03” t “E”
Using method:
1) The past self-diagnosis codes are displayed at page: 7, address:
BC to C6. Refer to “1-5. SELF-DIAGNOSIS FUNCTION” of
“SERVICE MANUAL, LEVEL 2” for detail of the self-diag-
nosis code.
Initializing method:
Order Page Address Data
Procedure
1
7
01
C0
2
7
00
01
Press PAUSE (Write) button.
3
7
B0 to C6
Check that the data is “00”.
4
7
00
00
5
7
01
00
6-74
DCR-HC47E/HC48/HC48E_ADJ
6-74E
DCR-HC48
FOR  CAMERA  COLOR  REPRODUCTION  ADJUSTMENT
Take  a copy of CAMERA COLOR
REPRODUCTION FRAME with a
clear sheet for use.
R-Y
B-Y
R
G
B
M
G
C
Y
Y
E
R-Y
B-Y
R
G
B
M
G
C
Y
Y
E
DCR-HC47E/HC48E
For NTSC model
For PAL model
Page of 77
Display