Sony DCR-DVD92 (serv.man3) Service Manual ▷ View online

6-25
DCR-DVD92/DVD92E/DVD103/DVD602/DVD602E/DVD653/DVD653E
[Preparation (Using the flange back adjustment jig)]
(Luminance: 300 to 400 lux)
1) Install the flange back adjustment jig so that the distance be-
tween it and the front of lens of camera is less than 3 cm.
2) Make the height of flange back adjustment jig and the camera
equal.
3) Check that the center of chart meets the center of shot image
screen with the zoom lens at TELE end and WIDE end respec-
tively.
Fig. 6-1-12
[Adjusting method]
1) Click the 
[Start]
 button of the CAMERA Adjustment 2.
2) The Automatic Adjustment Program executes “1. Data Setting
during Camera Adj.”.
3) Upon successful completion of the “1. Data Setting during
Camera Adj.”, the following message is displayed. Set the sub-
ject by referring to “Preparation”.
4) If the 
[OK]
 button is clicked, “2. Flange Back Adj.” and “3.
Release of Data Setting during Camera Adj.” will be executed.
5) Upon successful completion of all items of the CAMERA
Adjustment 2, the following message is displayed. Click the
[OK]
 button.
Flange back adjustment jig
Below 3 cm
Camera
4.
CAMERA Adjustment 2
(Using the minipattern box or flange back adjust-
ment jig)
[Automatic Adjustment Program execution items and
sequence]
1. Data Setting during Camera Adj.
2. Flange Back Adj.
3. Release of Data Setting during Camera Adj.
[Preparation (Using the minipattern box)]
1) The minipattern box is installed as shown in the following fig-
ure.
Note:
 The attachment lenses are not used.
2) Install the minipattern box so that the distance between it and
the front of lens of camera is less than 3 cm.
3) Make the height of minipattern box and the camera equal.
4) Check the output voltage of the regulated power supply is the
specified voltage 
±
 0.01 Vdc.
5) Check that the center of Siemens star chart meets the center of
shot image screen with the zoom lens at TELE end and WIDE
end respectively.
Specified voltage: The specified voltage varies according to the
minipattern box, so adjustment the power sup-
ply output voltage to the specified voltage writ-
ten on the sheet which is supplied with the mini-
pattern box.
Fig. 6-1-11
Minipattern box
Below 3 cm
Camera
Red (+)
Black (–)
Yellow (SENS +)
White (SENS –)
Black (GND)
Need not connected
Regulated power supply
Output voltage : Specified voltage 
±
 0.01 Vdc
Output current : more than 3.5 A
6-26
DCR-DVD92/DVD92E/DVD103/DVD602/DVD602E/DVD653/DVD653E
5.
CAMERA Adjustment 2
(Using the flange back adjustment chart and
subject more than 500 m away)
5-1. CAMERA Adjustment 2 (1)
[Automatic Adjustment Program execution items and
sequence]
1. Data Setting during Camera Adj.
2. Flange Back (1) Adj.
3. Release of Data Setting during Camera Adj.
[Preparation]
1) Place the Flange back adjustment chart at 2 m position away
from the lens.
2) Check that the center of Flange back adjustment chart meets
the center of shot image screen with the zoom lens at TELE
end and WIDE end respectively.
[Adjusting method]
1) Click the 
[Start  1 ]
 button of the CAMERA Adjustment 2.
2) The Automatic Adjustment Program executes “1. Data Setting
during Camera Adj.”.
3) Upon successful completion of the “1. Data Setting during
Camera Adj.”, the following message is displayed. Set the sub-
ject by referring to “Preparation”.
4) If the 
[OK]
 button is clicked, “2. Flange Back (1) Adj.” and
“3. Release of Data Setting during Camera Adj.” will be ex-
ecuted.
5) Upon successful completion of all items of the CAMERA
Adjustment 2 (1), the following message is displayed. Click
the 
[OK]
 button.
6) Perform “CAMERA Adjustment 2 (2)”.
( )
5-2. CAMERA Adjustment 2 (2)
[Automatic Adjustment Program execution items and
sequence]
1. Data Setting during Camera Adj.
2. Flange Back (2) Adj.
3. Release of Data Setting during Camera Adj.
[Preparation]
1) Set the zoom lens to the TELE end and expose a subject that is
more than 500 m away.
(subjects with clear contrast such as building, etc.)
(Nearby subjects less than 500 m away should not be in the screen)
[Adjusting method]
1) Click the 
[Start  2 ]
 button of the CAMERA Adjustment 2.
2) The Automatic Adjustment Program executes “1. Data Setting
during Camera Adj.”.
3) Upon successful completion of the “1. Data Setting during
Camera Adj.”, the following message is displayed. Set the sub-
ject by referring to “Preparation”.
4) If the 
[OK]
 button is clicked, “2. Flange Back (2) Adj.” will be
executed.
The following message is displayed during the execution of
adjustment, and then place the ND filter on the lens so as to
obtain the optimum image.
5) If “2. Flange Back Adj.” completed successfully, “3. Release
of Data Setting during Camera Adj.” will be executed.
6) Upon successful completion of all items of the CAMERA
Adjustment 2 (2), the following message is displayed. Click
the 
[OK]
 button.
(
)
6-27
DCR-DVD92/DVD92E/DVD103/DVD602/DVD602E/DVD653/DVD653E
6.
CAMERA Adjustment 3
[Automatic Adjustment Program execution items and
sequence]
1. Data Setting during Camera Adj.
2. Flange Back Check
3. Release of Data Setting during Camera Adj.
[Adjusting method]
1) Click the 
[Start]
 button of the CAMERA Adjustment 3.
2) The Automatic Adjustment Program executes “1. Data Setting
during Camera Adj.”.
3) Upon successful completion of the “1. Data Setting during
Camera Adj.”, the following message is displayed. Set the sub-
ject in accordance with the message.
4) If the 
[OK]
 button is clicked, “2. Flange Back Check” is ex-
ecuted. The following messages are displayed, and then oper-
ate the camera to make a check in accordance with the mes-
sages.
5) Upon completion of “2. Flange Back Check”, “3. Release of
Data Setting during Camera Adj.” is executed.
6) Upon successful completion of all items of the CAMERA
Adjustment 3, the following message is displayed. Click the
[OK]
 button.
6-28
DCR-DVD92/DVD92E/DVD103/DVD602/DVD602E/DVD653/DVD653E
7. Optical Axis Adjustment
Correct a deviation of optical axis between the lens and the CCD
imager.
If deviated, the screen center will be shifted when the lens is
zoomed from TELE end to WIDE end.
Subject
Siemens Star
Measurement Point
Check operation on monitor TV
Measuring Instrument
Adjustment Page
F
Adjustment Address
66
Note 1:
  Check that the data of page: 0, address: 10 is “00”.
Note 2:
“Flange Back Adjustment” must be already finished.
Note 3:
Check that the data of page: 6, address: 48 is “00”. If
not, set data: 00 to this address.
Switch setting:
1) POWER ............................................................. MOVIE mode
2) DIGITAL ZOOM (Menu setting) .................................... OFF
3) STEADYSHOT (Menu setting) ...................................... OFF
Preparation before adjustments:
1) Connect a DV camcorder to the monitor TV.
2) Playback the monoscope segment of the DV system check tape
(XH5-5 (NTSC), XH5-5P (PAL)).
3) Attach the optical axis frame chart (transparent) on the moni-
tor TV screen. Center of monoscope image and that of optical
axis frame must be agree.
4) Disconnect the DV camcorder from the monitor TV, and con-
nect the DVD camcorder to the monitor TV.
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: F, address: 66, and set data: 00, then press the
PAUSE button on the adjusting remote commander.
3) Place the Siemens Star at 2 m position away from the lens.
4) Shoot the Siemens Star with the zoom at TELE end.
5) Change the lens direction so that the center of Siemens Star
coincides with the center of optical axis deviation specifica-
tion frame.
6) Shoot the Siemens Star with the zoom at WIDE end.
7) Check on the monitor TV which area the center of Siemens
Star exists of the optical axis deviation specification frame.
At this time, measure the amount of deviation “L1” (distance
from the center of Siemens Star to the center of optical axis
deviation specification frame).
8) From the following table, read correction data according to
the area.
9) Select page: F, address: 66, and set correction data, then press
the PAUSE button on the adjusting remote commander.
10) Shoot the Siemens Star with the zoom at TELE end.
11) Change the lens direction so that the center of Siemens Star
coincides with the center of optical axis deviation specifica-
tion frame.
12) Shoot the Siemens Star with the zoom at WIDE end.
13) Measure the amount of deviation “L2” (distance from the cen-
ter of Siemens Star to the center of optical axis deviation speci-
fication frame).
Fig. 6-1-13
0
180
90
67.5
22.5
337.5
292.5
247.5
202.5
157.5
112.5
8
4
5
7
1
6
2
3
270
14) Compare L1 and L2, and make sure that the L2 is smaller than
L1.
If large, select page: F, address: 66, and set data: 00, then press
the PAUSE button on the adjusting remote commander.
Processing after completion of adjustment:
1) Select page: 0, address: 01, and set data: 00.
Area
1
2
3
4
5
6
7
8
Deviation Phase
22.6
°
 to 67.5
°
67.6
°
 to 112.5
°
112.6
°
 to 157.5
°
157.6
°
 to 202.5
°
202.6
°
 to 247.5
°
247.6
°
 to 292.5
°
292.6
°
 to 337.5
°
337.6
°
 to 22.5
°
Correction Data
01
02
03
04
05
06
07
08
Page of 80