Sony DCR-DVD408 (serv.man3) Service Manual ▷ View online

6-38
DCR-DVD408_ADJ
Name
DVD-R Disc
for Self Jitter
DVD-RW
Reference + DOW
Disc
DVD+RDL
Self Disc
Use
Diagnosis and adjustment of DVD-R
Diagnosis and adjustment of DVD-RW
Diagnosis and adjustment of DVD+RDL
Remark
This disc can be used about 78 times (min. 22 times) for the
diagnosis and adjustment. (Note 3)
This disc can be used about 1174 times for the diagnosis and
adjustment. (Note 3)
This disc can be used about 38 times (min. 9 times) for the
diagnosis and adjustment. (Note 3)
Table 6-2-1
Note 3: If the DVD-R Disc for Self Jitter, DVD-RW Reference + DOW Disc and DVD+RDL Self Disc exceeds the use limit, the
following message will be displayed. Replace it with a new disc and click the [OK] button in the message window.
The disc use counts are saved in the PC. Accordingly, the disc and PC used for diagnosis and adjustment must always be
controlled in the same combination.
If the disc is used with another PC, it will be recognized as a new disc, causing the use limit to be unknown.
Fig. 6-2-5
2-1-4.
Alignment disc
To diagnose and adjust the drive block, the discs listed in the following table are used.
Note 1: Use the specified disc that matches each diagnostic and adjustment item. (A message is displayed by the AUDIT)
If a wrong disc is used, the disc could be destroyed and could not be reused.
Note 2: Handle the disc with care, and before use, check if the disc is scratched or dirty.
6-39
DCR-DVD408_ADJ
2-2.
AUDIT (Drive Adjustment Program)
2-2-1.
Installation Method
Extract the compressed file in the ZIP format. If the extracted file (AUDIT for 2007.msi) is executed, the installer will start. Perform the
installation following the instructions given on the screen of the installer.
2-2-2.
AUDIT Starting Method
Click the [Start] button on the task bar, and from the [Programs], click [AUDIT for Service] – [AUDIT for 2007], and the AUDIT will start. The
SeusEX starts simultaneously with the start of AUDIT, and the operation screen appears only for a moment.
Again, the SeusEX starts and the operation screen is displayed, and after it is minimized for display at the lower left of the desktop, the
AUDIT operation screen appears. If the SeusEX cannot start (because, for instance, the HASP key is not connected to the PC), the AUDIT
also does not start.
2-2-3.
Description of Screen
Fig. 6-2-6
1. Diagnosis section
2. Adjustment section
3. Comment display section
4. Status display section
6. 
[SET]
 button
7. Menu section
5. 
[STOP]
 button
1.XX
8. Caution display 
section
6-40
DCR-DVD408_ADJ
1.
Diagnosis section
Use these buttons when diagnosing the drive block.
2.
Adjustment section
Use these buttons when adjusting the drive block.
3.
Comment display section
At the execution of diagnosis and adjustment, its progress situa-
tion is displayed.
1) [Clear] button
This button clears the comment in the display section.
2) [LOG] button
This button saves the comment in the display section as a log
file.
Fig. 6-2-7
4.
Status display section
The result of diagnosis and adjustment is displayed.
Fig. 6-2-8
5.
[STOP] button
This button stops the diagnosis and adjustment in the midway.
6.
[SET] button (After completing the TEST)
This button cancels the TEST mode set to the cam coder during
the diagnosis and adjustment. If the TEST mode is cancelled suc-
cessfully, the following message is displayed.
Note: Before exiting the AUDIT, be sure to cancel the TEST mode
by clicking the SET button of “After completing the TEST”.
Unless the TEST mode is cancelled, the drive may not op-
erate normally, such that “disc cover does not open”, “drive
error is displayed”, etc..
Fig. 6-2-9
7.
Menu section
1) [RESET] button
This button resets internal register.
(Use this button to interrupt the work so far when diagnosis
and adjustment stopped and no response is returned. The work
terminates with the previous adjustment data written to the
camcoder.)
2) [Lid Open] button
This button opens the disc cover.
8.
Caution display section
At the execution of POWER Adjustment, the caution of POWER
Adjustment is displayed.
Fig. 6-2-10
[Clear]
 button
[LOG]
 button
6-41
DCR-DVD408_ADJ
Order
Diagnostic item
Message
Disc
Operation
1
No Disc
Click the 
[START]
 button of “DIAGNOSIS”.
2
No Disc
Check the movement of the pickup lens (Focus
direction/Tracking direction), and click the
[OK]
 button in the message window.
3
No Disc
Check the movement of the sled, and click the
[OK]
 button in the message window.
4
No Disc
Check the rotation of the spindle, and click the
[OK]
 button in the message window.
Sensors
Fig. 6-2-11
2-3-2.
Diagnosing Method
2-3.
DIAGNOSIS
2-3-1.
Menu in Diagnosis Section
START button:
All items of diagnosis buttons are executed
in the descending order.
Diagnosis button: Only the diagnostic item assigned to the
button name is executed.
Status lamp:
Diagnosis status is displayed with color.
White
Not diagnosed
Red blinking
Diagnosis in progress
Green
Diagnosis OK
Red
Diagnosis NG
START button
Status lamp
Diagnosis buttons