DOWNLOAD Sony DCR-DVD105 (serv.man3) Service Manual ↓ Size: 1.63 MB | Pages: 82 in PDF or view online for FREE

Model
DCR-DVD105 (serv.man3)
Pages
82
Size
1.63 MB
Type
PDF
Document
Service Manual
Brand
Device
Movie / SECTION 6 ADJUSTMENTS BRAZIL
File
dcr-dvd105-sm3.pdf
Date

Sony DCR-DVD105 (serv.man3) Service Manual ▷ View online

6-38
DCR-DVD105
8.
CAMERA Adjustment 5
[Automatic Adjustment Program execution items and
sequence]
1. Data Setting during Camera Adj.
2. Steady Shot Check
3. Release of Data Setting during Camera Adj.
[Adjusting method]
1) Click the 
[Start]
 button of the CAMERA Adjustment 5.
2) The Automatic Adjustment Program executes “1. Data Setting
during Camera Adj.”.
3) Upon successful completion of the “1. Data Setting during
Camera Adj.”, the following message is displayed.
With the camcoder in stationary state, click the 
[OK]
 button.
4) If the 
[OK]
 button is clicked, “2. Steady Shot Check” is ex-
ecuted.
Upon successful completion of the “2. Steady Shot Check”,
the following message is displayed. Check that the steadyshot
function operates normally in accordance with the message.
5) If the 
[OK]
 button is clicked, “3. Release of Data Setting dur-
ing Camera Adj.” is executed.
6) Upon successful completion of all items of the CAMERA
Adjustment 5, the following message is displayed. Click the
[OK]
 button.
6-39
DCR-DVD105
1-6.
LCD/EVF SYSTEM ADJUSTMENTS
1.
Function of Each Button on LCD/EVF System
Adjustment Screen
Click the 
[LCD/EVF SYSTEM ADJUSTMENT]
 button on the
Main Menu screen, and the “LCD/EVF SYSTEM ADJUST-
MENT” screen in Fig. 6-1-14 will appear.
Fig. 6-1-14
1
[To Menu]
 button
The Main Menu screen comes back.
2
Model Select radio button
Selects the model to be adjusted.
Note:
NTSC model: DCR- DVD105/DVD605
PAL model: DCR- DVD105E/DVD605E
3
[Start]
 button
Each adjustment “LCD adjustment” or “EVF Adjustment” or
“Touch Panel Adjustment” starts.
4
[Release Data Setting]
 button
The data setting at the adjustment is cancelled.
During the data setting, the button color changes from “white”
to “red”. When the data setting is cancelled, the button color
returns to “white”.
(Use this button when an error occurred in the LCD/EVF ad-
justment. If the adjustment completed successfully, the data
setting is automatically cancelled and the button color returns
to “white”.)
2.
Adjustment Items of LCD/EVF System Adjustment
The adjustment items of LCD/EVF system adjustment are as listed
in Table 6-1-4. The Automatic Adjustment Program executes the
adjustment items if the LCD/EVF Adjustment Start button is
clicked.
Table 6-1-4
Button
Name
Adjustment
Page
Address
VCO Adj. (LCD)
0C
50, 51
Contrast Adj. (LCD)
0C
58
V-COM Adj. (LCD)
0C
52
VCO Adj. (EVF)
0C
3F, 40
Contrast Adj. (EVF)
0C
47
White Balance Adj. (EVF)
0C
45, 46
0C
56, 57
0C
7B, 7C
Transmissive Mode White
Balance Adj. (LCD)
Reflective Mode White
Balance Adj. (LCD)
Touch Panel Adj.
0A
90 to 93
LCD
Adjustment
EVF
Adjustment
Touch Panel
Adjustment
4
2
3
1
6-40
DCR-DVD105
5) If the 
[End]
 button is clicked, the following screen is displayed
during the execution of “4. Transmissive Mode White Balance
Adj.”. Check that the LCD screen is not colored. If colored,
using the 
[Up]
 / 
[Down]
 button on the screen, adjust so that
the LCD screen is not colored. After the adjustment, click the
[End]
 button in the screen.
6) If the 
[End]
 button is clicked, “5. Reflective Mode White Bal-
ance Adj.” will be executed.
7) Upon successful completion of the “5. Reflective Mode White
Balance Adj.”, “6. Release of Data Setting during LCD/EVF
Adj.” will be executed.
8) Upon successful completion of all item the LCD Adjustment,
the following message is displayed. Click the 
[OK]
 button.
3.
LCD Adjustment
[Automatic Adjustment Program execution items and
sequence]
1. Data Setting during LCD/EVF Adj.
2. LCD Automatic Adj.
(VCO Adj., Contrast Adj.)
3. V-COM Adj.
4. Transmissive Mode White Balance Adj.
5. Reflective Mode White Balance Adj.
6. Release of Data Setting during LCD/EVF Adj.
[Adjusting method]
1) Select the model with the Model Select radio button.
Note:
NTSC model: DCR- DVD105/DVD605
PAL model: DCR-DVD105E/DVD605E
2) Click the 
[Start]
 button of the LCD Adjustment.
3) The Automatic Adjustment Program executes the “1. Data
Setting during LCD/EVF Adj.” and “2. LCD Automatic Adj.”.
4) After that, the following screen is displayed during the execu-
tion of “3. V-COM Adj.”. Using the 
[Up]
 / 
[Down]
 button on
the screen, adjust so that the brightness of portions A and B on
the LCD panel is equal. After the adjustment, click the 
[End]
button in the screen.
6-41
DCR-DVD105
5.
Touch Panel Adjustment
[Automatic Adjustment Program execution items and
sequence]
1. Touch Panel Adj.
2. Release of Data Setting during LCD/EVF Adj.
[Adjusting method]
1) Click the 
[Start]
 button of the Touch Panel Adjustment.
2) The Automatic Adjustment Program executes the “1. Touch
Panel Adj.1”.The following message is displayed, and then
adjust the LCD screen in accordance with the instructions given
on the screen. After the adjustment, click the 
[OK]
 button in
the message window.
3) If the 
[OK]
 button is clicked, “2. Release of Data Setting dur-
ing LCD/EVF Adj.” will be executed.
4) Upon successful completion of all item the Touch Panel Ad-
justment, the following message is displayed. Click the 
[OK]
button.
4.
EVF Adjustment
[Automatic Adjustment Program execution items and
sequence]
1. Data Setting during LCD/EVF Adj.
2. EVF Automatic Adj.
(VCO Adj., Contrast Adj.)
3. White Balance Adj.
4. Release of Data Setting during LCD/EVF Adj.
[Adjusting method]
1) Select the model with the Model Select radio button.
Note:
NTSC model: DCR- DVD105/DVD605
PAL model: DCR-DVD105E/DVD605E
2) Click the 
[Start]
 button of the EVF Adjustment.
3) The Automatic Adjustment Program executes the “1. Data
Setting during LCD/EVF Adj.” and “2. EVF Automatic Adj.”.
4) After that, the following screen is displayed during the execu-
tion of “3. White Balance Adj.”. Check that the EVF screen is
not colored. If colored, using the 
[Up]
 / 
[Down]
 button on the
screen, adjust so that the EVF screen is not colored. After the
adjustment, click the 
[End]
 button in the screen.
5) If the 
[End]
 button is clicked,“4.Release of Data Setting dur-
ing LCD/EVF Adj.” will be executed.
6) Upon successful completion of all item the EVF Adjustment,
the following message is displayed. Click the 
[OK]
 button.
Page of 82
Display

Click on the first or last page to see other DCR-DVD105 (serv.man3) service manuals if exist.