DOWNLOAD Sony DCR-DVD100 / DCR-DVD100E (serv.man4) Service Manual ↓ Size: 933.62 KB | Pages: 52 in PDF or view online for FREE

Model
DCR-DVD100 DCR-DVD100E (serv.man4)
Pages
52
Size
933.62 KB
Type
PDF
Document
Service Manual
Brand
Device
Movie / SECTION 6 ADJUSTMENTS
File
dcr-dvd100-dcr-dvd100e-sm4.pdf
Date

Sony DCR-DVD100 / DCR-DVD100E (serv.man4) Service Manual ▷ View online

6-8
DCR-DVD100/DVD100E
COVER
COVER
1-2.
INITIALIZATION OF A, B, C, D, E, F, 1F
PAGE DATA
Note:
When reading or writing the 1F page data, select page: 0, address:
10, and set data: 01, then select F page. The 1F page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
1-2-1.
INITIALIZATION OF A, B, C, D PAGE DATA
Note:
The data of page: 0, address: 10 must be “00”.
1. Initializing the A, B, C, D Page Data
Note1:
Reading/writing the C page data by using the 
 is
impossible.
Note2:
If the B page data has been initialized, the following adjustments
need to be performed again.
1) Viewfinder system adjustments
2) LCD system adjustments
3) Video system adjustments
Note3:
NTSC model: DCR-DVD100
PAL model: DCR-DVD100E
Adjusting page
A
Adjusting Address
10 to FF
Adjusting page
B
Adjusting Address
30 to FF
Adjusting page
C
Adjusting Address
10 to FF
Adjusting page
D
Adjusting Address
10 to 75
Initializing Method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
0
10
00
Set the data.
3
7
03
Set the following data.
00(NTSC), 80(PAL)
4
7
00
XX
Set the data. (Note4)
5
7
01
XX
Set the data, and press PAUSE
button. (Note4)
6
7
02
Check that the data changes to
“01”
7
Perform “Modification of A, B,
C, D Page Data”.
Note4:
XX=20 : Initializing A page
XX=21 : Initializing B page
XX=23 : Initializing D page
XX=24 : Initializing C page
XX=28 : Initializing A, B, C and D page
2. Modification of A, B, C, D Page Data
If the A, B, C or D page data has been initialized, change the data of
the  “Fixed data-2” address of the initialized page shown in the
following tables by manual input.
Modifying Method:
1)
Before changing the data, select page: 0, address: 01, and set
data: 01.
2)
New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note:
If copy the data built in the different model, the camcorder may
not operate.
3)
When changing the data, press the PAUSE button of the
adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
Processing after Completing Modification of A, B, C, D Page data
Order Page Address Data
Procedure
1
0
01
00
Set the data.
2
Turn off the power and turn on
again
Note:
If the following symptoms occur after completing of the
“Modification of A, B, C, D page data”, check that the data of the
“Fixed data-2” addresses of A and D page are same as those of the
same model of the same destination.
1) The self-diagnosis code “E:20:00” on the LCD screen is displayed.
2) The power is shut off so that unit cannot operate.
6-9
DCR-DVD100/DVD100E
3. A Page Table
Note1:
The data of page: 0, address: 10 must be “00”.
Note2:
Fixed data-1: Initialized data. (Refer to “1. Initializing the A, B,
C, D Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of A, B,
C, D Page Data”).
4. B Page Table
Note1:
The data of page: 0, address: 10 must be “00”.
Note2:
Fixed data-1: Initialized data. (Refer to “1. Initializing the A, B,
C, D Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of A, B,
C, D Page Data”).
Table. 6-1-2.
Address
Remark
00 to 0F
10 to 17
18
19 to FF
Fixed data-1
Fixed data-2
Fixed data-1
Table. 6-1-3.
00 to 2F
30
31
32
33
34
35
36
37 to 40
41
42
43
44 to 47
48
49 to 4A
4B
4C to 50
51
52
53
54
55
56
57
58
59 to 60
61
62
63
64
65
66
67
68
69
6A
6B to FF
88
9A
6E
68
80
97
8D
73
37
68
82
A2
A3
07
3E
7D
65
26
3D
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
S VIDEO out Y level adj.
S VIDEO out chroma level adj.
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
VCO adj. (EVF)
Fixed data-1
RGB AMP adj. (EVF)
Fixed data-1
White balance adj. (EVF)
Contrast adj. (EVF)
Fixed data-1
VCO adj. (LCD)
V COM adj. (LCD)
Bright adj. (LCD)
Black limit adj. (LCD)
PSIG GRAY adj. (LCD)
White balance adj. (LCD)
Contrast adj. (LCD)
Center level adj. (LCD)
Fixed data-1
Address
Remark
Initial value
6-10
DCR-DVD100/DVD100E
5. C Page Table
Note1:
Reading/writing the C page data by using the                        is
impossible.
Note2:
The data of page: 0, address: 10 must be “00”.
Note3:
Fixed data-1: Initialized data. (Refer to “1. Initializing the A, B,
C, D Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of A, B,
C, D Page Data”).
6. D Page Table
Note1:
The data of page: 0, address: 10 must be “00”.
Note2:
Fixed data-1: Initialized data. (Refer to “1. Initializing the A, B,
C, D Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of A, B,
C, D Page Data”).
Table. 6-1-4.
Address
Remark
00 to 0F
10 to FF Fixed data-1
Table. 6-1-5.
00 to 0F
10
11
12
13 to 15
16
17 to 18
19
1A to 37
38
39 to 3E
3F
40 to 6E
6F
70 to 75
00
Test mode
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Address
Remark
Initial value
6-11
DCR-DVD100/DVD100E
Address
Remark
00 to 13
14
15
16
17
18 to 26
27
28 to FF
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
1-2-2.
INITIALIZATION OF E, F, 1F PAGE DATA
Note:
When reading or writing the E, F page data, select page: 0, address:
10, and set data: 00.
When reading or writing the 1F page data, select page: 0, address:
10, and set data: 01, then select F page. The 1F page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
1. Initializing the E, F, 1F Page Data
Note1:
If “Initializing the E, F, 1F Page Data” is performed, all data of the
E page, F page and 1F page will be initialized. (It is impossible to
initialize a single page.)
Note2:
If the E, F, 1F page data has been initialized, following adjustments
need to be performed again.
1) Modification of E, F, 1F page data
2) Camera system adjustments
Note3:
NTSC model: DCR-DVD100
PAL model: DCR-DVD100E
Adjusting page
E
Adjusting Address
00 to FF
Adjusting page
F
Adjusting Address
10 to FF
Adjusting page
1F
Adjusting Address
00 to F7
Initializing Method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
0
10
00
Set the data.
3
6
01
Set the following data, and press
PAUSE button.
2D (NTSC), 2F (PAL)
4
6
03
01
Set the data, and press PAUSE
button.
5
6
02
Check that the data changes to
“01”.
6
Perform “Modification of E, F,
1F Page Data”.
2. Modification of E, F, 1F Page Data
If the E, F, 1F page data has been initialized, change the data of the
“Fixed data-2” address shown in the following table by manual input.
Modifying Method:
1)
Before changing the data, select page: 0, address: 01, and set
data: 01.
2)
When changing the E, F page data, select page: 0, address: 10,
and set data: 00.
3)
When changing the 1F page data, select page: 0, address: 10,
and set data: 01.
After completing the modification of 1F page data, reset the
data of this address to “00”.
4)
New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note:
If copy the data built in the different model, the camcorder may
not operate.
5)
When changing the data, press the PAUSE button of the
adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
6)
Check that the data of adjustment addresses is the initial value.
If not, change the data to the initial value.
Processing after Completing Modification of E, F, 1F Page data
Order Page Address Data
Procedure
1
0
10
00
Set the data.
2
2
00
29
Set the data.
3
2
01
29
Set the data, and press PAUSE
button.
4
Perform  “36MHz Origin Osc.
Adjustment” of the camera system
adjustment.
3. E Page Table
Note1:
The data of page: 0, address: 10 must be “00”.
Note2:
Fixed data-1: Initialized data. (Refer to “1. Initializing the E, F, 1F
Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of E, F,
1F Page Data”).
Table. 6-1-6.
Page of 52
Display