DOWNLOAD Sony CCD-TRV300E Service Manual ↓ Size: 18.73 MB | Pages: 127 in PDF or view online for FREE

Model
CCD-TRV300E
Pages
127
Size
18.73 MB
Type
PDF
Document
Service Manual
Brand
Device
Movie / S/M CCD-TRV300E ''98 AEP
File
ccd-trv300e.pdf
Date

Sony CCD-TRV300E Service Manual ▷ View online

5-11
5. E Page Table
Note 1:
Fixed data-1 : Initialized data.
( Refer to “1. Initializing the D,E,F Page Data”.)
Fixed data-2 : Modified data.
(Refer to “2. Modification of D, E, F Page Data”).
Note 2:
See “1-5. LCD SYSTEM ADJUSTMENT”.
Address
Initial Value Remark
Address
Initial Value
Remark
38
Fixed data-2
39
3A
3B
Fixed data-1
3C
3D
3E
3F
Fixed data-2
40
41
42
43
44
45
46
47
48
49
4A
4B
4C
4D
4E
4F
50
Fixed data-1
51
52
Fixed data-2
53
Fixed data-1
54
55
56
57
58
59
Fixed data-2
5A
Fixed data-1
5B
5C
Fixed data-2
5D
Fixed data-1
5E
5F
60
Fixed data-2
61
62
63
64
65
66
67
68
Fixed data-1
69
6A
6B
6C
6D
6E
6F
70
Fixed data-2
71
72
Fixed data-1
73
Fixed data-2
74
Fixed data-1
75
Fixed data-2
76 to 99
Fixed data-1
00
Fixed data-1
01
02
03
04
05
06
07
08
09
0A
0B
0C
0D
0E
0F
10
11
12
13
14
15
16
17
Fixed data-2
18
19
Fixed data-1
1A
1B
Fixed data-2
1C
1D
1E
Fixed data-1
1F
20
21
22
Fixed data-2
23
24
Fixed data-1
25
26
27
Fixed data-2
28
Fixed data-1
29
2A
2B
Fixed data-2
2C
2D
2E
2F
30
31
32
33
34
35
36
37
5-12
D9
Note 2
Color adj. (LCD)
DA
Fixed data-1
DB
Fixed data-2
DC
Fixed data-1
DD
DE
DF
E0
E1
E2
E3
E4
E5
E6
E7
E8
E9
EA
Fixed data-2
EB
EC
Fixed data-1
ED
EE
EF
Fixed data-2
F0
Fixed data-1
F1
F2
F3
Fixed data-2
F4
Fixed data-1
F5
F6
F7
F8
F9
FA
FB
FC to FF
Address
Initial Value
Remark
Address
Initial Value
Remark
9A
Fixed data-2
9B
Fixed data-1
9C
Fixed data-2
9D
Fixed data-1
9E
9F
A0
Fixed data-2
A1
A2
A3
A4
Fixed data-1
A5
A6
A7
A8
A9
AA
AB
AC
AD
AE
AF
B0
B1
B2
B3
B4
B5
B6
B7
B8
B9
BA
BB
BC
Fixed data-2
BD
BE
BF
Note 2
VCO adj. (LCD)
C0
Fixed data-2
C1
C2
Fixed data-1
C3
C4
C5
C6
C7
C8
C9
CA
CB
CC
CD
CE
CF
Note 2
Bright adj. (LCD)
D0
Note 2
Color adj. (LCD)
D1
Note 2
White balance adj. (LCD)
D2
Note 2
White balance adj. (LCD)
D3
Note 2
Contrast adj. (LCD)
D4
Note 2
D range adj. (LCD)
D5
Note 2
V-COM level adj. (LCD)
D6
Note 2
VCO adj. (LCD)
D7
Note 2
V-COM adj. (LCD)
D8
Fixed data-1
5-13
1-3. CAMERA SYSTEM ADJUSTMENTS
Before perform the camera system adjustments, Check that the
specified value of “28MHz Origin Oscillation Adjustment”, “Y OUT
level Adjustment” and “C OUT level Adjustment” of “VIDEO
SYSTEM ADJUSTMENT” are satisfied.
1. G-CAM flip Adjustment
Set the color reproduction conditions to optimum.
Subject
Color bar chart standard picture frame
Measurement Point
Display data of page 1 of the adjusting
remote commander (Note 1)
Measuring Instrument
Adjustment Page
F
Adjustment Address
21
Note 1.
Displayed data of page 1 of the adjusting remote
commander.
1 : XX : XX
n S2
n S1
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 0, address: 03, and set data: 16.
3) Select page: F, address: 21, set data: D2, and press the PAUSE
button of the adjusting remote commander.
4) Select page 1 of the adjusting remote commander, and compare
the higher 2 digits (S1) and lower 2 digits (S2) of the 4-degits
display data.
When S1<S2
Perform steps 5) onwards.
When S1  S2
Perform steps “Processing after Completing Adjustments”.
5) Select page: F, address: 21, set data: 52, and press the PAUSE
button of the adjusting remote commander.
Processing after Completing Adjustments
1) Select page: 0, address: 03, and set data: 00.
2) Select page: 0, address: 01, and set data: 00.
5-14
2. HALL Adjustment
For detecting the position of the lens iris, adjust the hall AMP gain
and offset.
Subject
Not required
Measurement Point
DDS display data of LCD or TV monitor
(Note 3)
Measuring Instrument
Adjustment Page
F
Adjustment Address
2F, 30
Specified Value
96 to 9A during IRIS OPEN (Note 1)
1C to 20 during IRIS CLOSE (Note 2)
Note 1:
Select page: 2, address: 01, set data: 01, and press the
PAUSE button of the adjusting remote commander.
Note 2:
Select page: 2, address: 01, set data: 03, and press the
PAUSE button of the adjusting remote commander.
Note 3:
DDS display data of LCD or TV monitor.
00 00XX
n Object data
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 0, address: 03, and set data: 03.
3) Select page: D, address: 11, set data: 02, and press the PAUSE
button of the adjusting remote commander.
4) Select page: 2, address: 01, set data: 03, and press the PAUSE
button.
5) Select page: F, address: 30, set data: 80, and press the PAUSE
button.
6) Select page: F, address: 2F, set data: 40, and press the PAUSE
button.
7) Read the DDS display data (the bottom two digits of the display
data at the bottom right of the LCD display or the TV monitor),
and this data is named K
2
.
8) Select page: F, address: 2F, set data: 30, and press the PAUSE
button.
9) Read the DDS display data, and this data is named K
1
.
10) Select page: 2, address: 01, set data: 01, and press the PAUSE
button.
11) Read the DDS display data, and this data is named W
1
.
12) Select page: F, address: 2F, set data: 40, and press the PAUSE
button.
13) Read the DDS display data, and this data is named W
2
.
14) Convert W
1
, W
2
, K
1
, K
2
, to decimal notation, and obtain W
1
' ,
W
2
' , K
1
' , K
2
'. (Refer to Table 5-1-2. “Hexadecimal notation -
decimal notation conversion table”.)
15) Calculate X
1
' using the following equations (decimal notation
calculation).
A’= W
2
'+ K
1
'– W
1
'– K
2
'
Equation 1
B’= W
1
' – K
1
'
Equation 2
X
1
'=[1952+(48 x A’)–(16 x B’)] / A’
Equation 3
16) Convert X
1
' to hexadecimal notation, and obtain X
1
.
(Round off to one decimal place)
17) Select page: F, address: 2F, set data: X
1
, and press the PAUSE
button.
18) Select page: 2, address: 01, and set data: 01, and press the PAUSE
button.
19) Select page: F, address: 30, change the data and adjust the DDS
display data to “98”.
20) Press the PAUSE button of the adjusting remote commander.
21) Select page: 2, address: 01, and set data: 03, and press the PAUSE
button.
22)Read the DDS display data, and this data is named K
0
. If K
0
 lies
within the “1C” to “20” range, perform “Processing after
completing adjustments”. If it is lies outside the range, perform
the following adjustments.
23)Convert K
0
 to decimal notation, and obtain K
0
'.
24)Calculate X
2
' using the following equations (decimal notation
calculation).
C’= 152 – B’– K
0
'
Equation 4
X
2
'=[(122 – B’) x ( X
1
' – 48)+(48 x C’)] / C’
Equation 5
( X
1
' and B’ are values obtained from equations 2) and 3) )
25)Convert X
2
' to hexadecimal notation, and obtain X
2
.
(Round off to one decimal place)
26)Select page: F, address: 2F, set data: X
2
, and press the PAUSE
button.
27)Select page: 2, address: 01, set data: 03, and press the PAUSE
button.
28)Select page: F, address: 30, change the data and adjust the DDS
display data to “1E”.
29)Press the PAUSE button of the adjusting remote commander.
30)Select page: 2, address: 01, set data: 01, and press the PAUSE
button.
31)Check the DDS display data lies within the “96” to “9A” range.
Processing after Completing Adjustments
1) Select page: D, address: 11, and set data: 00, and press the PAUSE
button.
2) Select page: 0, address: 01, and set data: 00.
3) Select page: 2, address: 01, and set data: 00, and press the PAUSE
button.
4) Select page: 0, address: 03, and set data: 00.
Page of 127