Sony CCD-TRV101 / CCD-TRV101E Service Manual ▷ View online

6-4
1-1-4. Adjustment remote commander (RM-95 upgraded)
To perform adjustment, the adjustment data stored in the non-volatile
memory must be rewritten using the adjustment remote commander
(RM-95 upgraded).
The adjustment remote commander uses the remote commander signal
line (LANC) to interactively communicate with the merchandise.  The
page, address and up/down command data are sent from the
adjustment remote commander to the merchandise.  In return, the
page, address and data are sent to the adjustment remote commander
from the merchandise.
1. Using the adjustment remote commander
1)
Connect the adjustment remote commander to the LANC
terminal (JK-147 board J101).
2)
Set the NOR-ADJ (or HOLD) switch of the adjustment remote
commander to the “ADJ” (or ON) (service) position.
If the adjustment remote commander is correctly connected, the
adjustment remote commander’s LED will show the display as
shown in Fig. 6-1-6.
3)
Bit value discrimination
It is necessary to discriminate between the bit values with the
data displayed on the adjustment remote commander for all
following items. Identify whether the bit value is “1” or “0” with
the use of the following diagram.
Fig. 6-1-6.
4)
The adjustment remote controller is operated as follows:
Changing the page
The pages increase when the EDIT SEARCH (+) button is
pressed and decrease when the EDIT SEARCH (–) button is
pressed. Altogether there are 16 pages from page “0” to page
“F”.
Changing the address
The address increases when the FF (
)) button is pressed, and
decreases when the REW (
0) button is pressed.  Altogether
there are 256 addresses from address “00” to address “FF”.  Some
addresses, which are not used during adjustment, do not appear.
(Example)
If “8E” is displayed on the adjustment remote commander,
the bit values for bit7 to bit4 are shown in the ‘A’ column,
and the bit values for bit3 to bit0 are shown in the ‘B’
column.
Taking note the already-stored adjustment data
The previous adjustment can be erased if the adjustment remote
commander is incorrectly handled.  To prevent this, it is
recommended that all the stored adjustment data be noted down
on the attached page F address list.
Changing the data (Data setting)
The data increases when the PLAY (
() button is pressed, and
decreases when the STOP (
p) button is pressed.  Altogether
there 256 data from data “00” to data “FF”.
Storing the data
Press the PAUSE button to store the adjustment data (page F)
into the non-volatile memory.
(If the PAUSE button is not pressed after completing the
adjustment, the new adjustment data will not be stored in the
non-volatile memory.)
5)
After completing all adjustments, turn off the main power supply
(7.2 V) once.  This releases the adjustment mode (all modes
except for page F).
0 1 2 3 4 5 6 7 8 9 A B C D E F
0 1 2 3 4 5 6 7 8 9 A b c d E F
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Hexadecimal
notation
LCD display
Decimal
notation after
conversion
Display on the
adjustment
remote
commander
0
1
2
3
4
5
6
7
8
9
A (
A
)
B (
b
)
C (
c
)
D (
d
)
E (
E
)
F (
F
)
Bit values
bit3
or
bit7
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
bit2
or
bit6
0
0
0
0
1
1
1
1
0
0
0
0
1
1
1
1
bit1
or
bit5
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
bit0
or
bit4
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
A
B
6-5
[Sequence of Service Models Using the Adjustment Remote
Commander]
Command Name
Command Function
Normal LANC Command
Page Up
Page + 1
Edit Search +
Page Down
Page – 1
Edit Search –
Direct Page Set
Sets the specified page
Event Clear
Address Up
Address + 1
Fast Forward
Address Down
Address – 1
Rewind
Data Up
Data + 1
Play Back
Data Down
Data – 1
Stop
Store
Stores data in the EE PROM. Pause
2. Precautions when using the adjustment remote
commander
Mishandling of the adjustment remote commander may erase the
correct adjustment data which has already been stored in the memory.
To prevent this, it is recommended that all adjustment data is noted
down on the attached page F address list before starting adjustments
in addition to all new adjustment data after the completion of each
adjustment step.
6-6
1-1-5. Page F address list
Note 1 :
The initial value of the adjustment data is the data
immediately after execution of Pages E and F data
initialization, and Page F data modification. They are
different from the value after all adjustments are executed.
Note 2 :
When the arrow mark 
 is shown in the memo column of
the adjustment data, it indicates that the data of that address
is the fixed data (fixed to the initial value).
Address
00
01
02
03
04
05
06
07
08
09
0A
0B
0C
0D
0E
0F
10
11
12
13
14
15
16
17
18
19
1A
1B
1C
1D
1E
1F
20
21
22
23
24
25
26
27
28
29
2A
Initial Value
00
00
00
00
00
00
00
00
00
00
00
00
[76] (77)
00
23
52
[00] (02)
03
3B
00
7C
00
5F
[41] (41 : E, AUS, HK/40 : AEP)
44 (C4)
00
FE
Memo Column













Adjustment Data
Address
2B
2C
2D
2E
2F
30
31
32
33
34
35
36
37
38
39
3A
3B
3C
3D
3E
3F
40
41
42
43
44
45
46
47
48
49
4A
4B
4C
4D
4E
4F
50
51
52
53
54
55
Initial Value
3B
77
56
CD
19
92
21
12
14
00
00
00
80
80
80
20
80
80
40
1B
1B
AE
42
44
34
2A
89
59
38
41
41
00
19
00
2E
00
00
00
00
80
80
00
00
Memo Column
Adjustment Data
Table 6-1-1 (1).
Table 6-1-1 (2).
No mark : NTSC/PAL
[   ] :
NTSC
(   ) :
PAL
Hong Kong model is abbreviated as HK.
Australian model is abbreviated as AUS.
6-7
Address
56
57
58
59
5A
5B
5C
5D
5E
5F
60
61
62
63
64
65
66
67
68
69
6A
6B
6C
6D
6E
6F
70
71
72
73
74
75
76
77
78
79
7A
7B
7C
7D
7E
7F
80
81
82
83
84
85
86
Initial Value
00
00
00
[7E] (5F)
[9E] (7D)
[9C] (7D)
3C
00
7A
8D
7A
3A
C0
00
A2
50
8A
D8
[46] (40)
40
[28] (20)
[00] (F8)
[99] (AA)
[6B] (65)
A2
[6A] (70)
D5
D5
D5
D5
[9A] (9B)
[8F] (8A)
BC
BC
BC
BC
00
00
00
00
7E
80
7C
80
0C
[18] (00)
76
40
75
Memo Column




Adjustment Data
Address
87
88
89
8A
8B
8C
8D
8E
8F
90
91
92
93
94
95
96
97
98
99
9A
9B
9C
9D
9E
9F
A0
A1
A2
A3
A4
A5
A6
A7
A8
A9
AA
AB
AC
AD
AE
AF
B0
B1
B2
B3
B4
B5
B6
B7
Initial Value
73
12
95
A5
68
4A
F0
00
01
[68] (28)
[80] (60)
[6F] (10)
[60] (5A)
68
70
40
[2E] (25)
[58] (28)
[A0] (70)
[30] (10)
[14] (4A)
[58] (28)
[C0] (FF)
[30] (10)
[26] (25)
[78] (28)
70
[4C] (30)
[06] (00)
[58] (28)
D0
[60] (30)
[0F] (00)
[62] (60)
91
[62] (70)
[A2] (92)
[62] (70)
[91] (A2)
[62] (70)
[A2] (A3)
04
[D4] (D5)
04
[D5] (D6)
40
00
B3
B3
Memo Column
















































Adjustment Data
Table 6-1-1 (3).
Table 6-1-1 (4).
No mark : NTSC/PAL
[   ] :
NTSC
(   ) :
PAL
Page of 127
Display

Click on the first or last page to see other CCD-TRV101 / CCD-TRV101E service manuals if exist.