DOWNLOAD Sony CCD-TR3200E Service Manual ↓ Size: 16.58 MB | Pages: 127 in PDF or view online for FREE

Model
CCD-TR3200E
Pages
127
Size
16.58 MB
Type
PDF
Document
Service Manual
Brand
Device
Movie
File
ccd-tr3200e.pdf
Date

Sony CCD-TR3200E Service Manual ▷ View online

5-21
Subject
Pattern A
Measurement Point
Video output terminal
Measuring Instrument
Oscilloscope
Adjustment Page
F
Adjustment Address
44
12. Steady shot adjustment
• Perform the steady shot adjustment only when replacing the
angular velocity sensor. When the microprocessor, circuit, etc.
malfunctions, do not perform this adjustment but check operations
only.
• Record the sensitivity label of the angular velocity sensor (repair
part), including to which side of the board it was attached to, etc.
If it has been attached incorrectly, the image will move up and
down or to the left and right during steady shot operation. Be sure
to take note of this.
Precautions on the Parts Replacement
There are two types of repair parts.
Type A ENC03EA or ENC03JA
Type B ENC03EB or ENC03JB
Replace the broken sensor with a same type sensor. If replace with
other type parts, the image will vibrate up and down or left and
right during hand-shake correction operations. After replacing, re-
adjust according to the adjusting method after replacement.
Precautions on Angular Velocity Sensor
The sensor incorporates a precision oscillator. Handle it with care
as if it dropped, the balance of the oscillator will be disrupted and
operations will not be performed properly.
Switch setting:
1) Steady Shot (Menu display) ...........................................ON
2) Digital zoom (Menu display) .........................................OFF
Adjusting method:
1) Expose pattern A with the zoom TELE end.
Note:
Digital zoom (Menu display) ............................... OFF
2) Adjust the inclination of the camera so that the vertical black
line comes to the center of the screen.
3) Select page: 0, address: 01, and set data: 01.
4) Select page: E, address: 4E, set data: 08, and press the pause
button of the adjusting remote commander.
5) Adjust to the falling edge of the waveform with vertical scale
on the oscilloscope. (Oscilloscope is H period).
6) Select page: E, address: 4E, set data: 09, and press the pause
button of the adjusting remote commander.
At this time, measure the moving amount t1 (
µ
sec) of the falling
edge of the waveform.
7) Obtain D
44
' using the following equation (decimal calculation).
D
44
' = (4.00/t1) x [0.58/(SE602 sensor sensitivity)] x 84
Note:
The SE602 sensor sensitivity of the VP-47 board is labeled
only on the repair part.
8) Raise D
44
' to a whole number, convert it to a hexadecimal digit
and take this as D
44
. (Refer to Table 5-1-2. “Hexadecimal
notation-Decimal notation conversion table”.)
9) Select page: F, address: 44, set data: D
44
, and press the pause
button of the adjusting remote commander.
10) Select page: E, address: 4E, set data: 08, and press the pause
button.
Procedure after adjustment
1) Select page: 0, address: 01, and set data: 00.
2) Check that the steady shot operation is performed normally.
12-1. Steady Shot Adjustment (1)
Fig. 5-1-12.
Fig. 5-1-11.
Pattern A
Black
A4 size (297mm x 210mm)
White
White
H
Falling edge of waveform
when data is 08
Falling edge of waveform
when data is 09
t1 (
µ
sec)
5-22
Fig. 5-1-13.
Adjusting method:
1) Expose pattern B with the zoom TELE end.
Note:
Digital zoom (Menu display) ...............................OFF
2) Adjust the inclination of the camera so that the horizontal black
line comes to the center of the screen.
3) Select page: 0, address: 01, and set data: 01.
4) Select page: E, address: 4D, set data: 08, and press the pause
button of the adjusting remote commander.
5) Adjust to the falling edge of the waveform with vertical scale
on the oscilloscope. (Oscilloscope is V period).
6) Select page: E, address: 4D, set data: 09, and press the pause
button of the adjusting remote commander.
At this time, measure the moving amount t2 (msec) of the falling
edge of the waveform.
7) Obtain D
43
' using the following equation (decimal calculation).
D
43
' = (1.88/t2) x [0.62/ (SE601 sensor sensitivity)] x 77
Note:
The SE601 sensor sensitivity of the VP-47 board is labeled
only on the repair part.
8) Raise D
43
' to a whole number, convert it to a hexadecimal digit
and take this as D
43
. (Refer to Table 5-1-2. “Hexadecimal
notation-Decimal notation conversion table”.)
9) Select page: F, address: 43, set data: D
43
, and press the pause
button of the adjusting remote commander.
10) Select page: E, address: 4D, set data: 08, and press the pause
button.
Procedure after adjustment
1) Select page: 0, address: 01, and set data: 00.
2) Check that the steady shot operation is performed normally.
Subject
Pattern B
Measurement Point
Video output terminal
Measuring Instrument
Oscilloscope
Adjustment Page
F
Adjustment Address
43
12-2. Steady Shot Adjustment (2)
Fig. 5-1-14.
V
Falling edge of waveform
when data is 08
Falling edge of waveform
when data is 09
t2 (msec)
Pattern B
Black
A4 size (297mm x 210mm)
White
White
5-23
1-4. MONOCHROME ELECTRONIC VIEWFINDER
SYSTEM ADJUSTMENTS
1-4-1. Horizontal Slant Check
Adjusting method:
1) Adjust RV904 (BRIGHT) (VF-104 board) so that the CRT can
be seen easily and clearly.
2) Check that the difference between the horizontal line and the tilt
of the black mask satisfies the specified value.
Mode
Playback
Signal
Alighment tape :
For checking operations
(WR5-8CSE)
Monoscope section
Specified Value
±
 1.5 
°
Fig. 5-1-15.
Fig. 5-1-16.
1-4-2. Centering Adjustment
Adjusting method:
1) Use the centering adjustment ring and adjust so that the left,
right, top, and bottom sides of the display are uniform. (Refer to
Fig. 5-1-16.)
Note :
As the centering position changes due to earth magnetism,
rotate it 360˚ in the horizontal direction, and adjust with
the center section of the modifying position.
Mode
Playback
Signal
Alighment tape :
For checking operations
(WR5-8CSE)
Monoscope section
Specified Value
±
 4%
Mode
Playback
Signal
Alighment tape :
For checking operations
(WR5-8CSE)
Monoscope section
Fig. 5-1-17.
1-4-3. Focus Adjustment
Adjusting method:
1) Adjust the focus ring to obtain the optimum focus. (Refer to Fig.
5-1-16.)
RV903
RV904
SOL901
VF-104 BOARD (SIDE A)
5-24
1-4-4. Aberration Adjustment
Mode
VTR stop
Signal
Dot pattern
Specified Value
b1   2 • a1
b2   0.8 • a2
Adjusting method:
1) Adjust the aberration adjustment ring so that the tracing of the
dot satisfies the specified value.
2) If the centering becomes displaced here, perform the centering
adjustment from the beginning again.
Fig. 5-1-18.
1-4-5. Horizontal Amplitude Adjustment
(VF-104 board)
Mode
Playback
Signal
Alighment tape :
For checking operations
(WR5-8CSE)
Monoscope section
Adjusting Element
C909 (SOL901)
Specified Value
14 
±
 6%
Adjusting method:
1) Rotate RV903, and adjust the top and bottom sides of the
monoscope image to the top and bottom edges of the display.
2) Rotate RV904 so that the brightness is the normal level.
3) Solder or unsolder SOL901 pattern of the H size adjustment
capacitor (C909) to “short” or “open”, so that the horizontal
direction over scan becomes 14 
±
 6% (Left and right totals).
Fig. 5-1-19.
SOL901
Size H
Open
Small
Short
Big
RV903
RV904
SOL901
VF-104 BOARD (SIDE A)
Page of 127
Display

Click on the first or last page to see other CCD-TR3200E service manuals if exist.