DOWNLOAD Sony CCD-TR315 / CCD-TR416 / CCD-TR416PK / CCD-TR516 / CCD-TR516PK / CCD-TR716 / CCD-TRV16 / CCD-TRV16PK / CCD-TRV36 / CCD-TRV36PK / CCD-TRV43 / CCD-TRV46 / CCD-TRV46PK (serv.man2) Service Manual ↓ Size: 17.11 MB | Pages: 127 in PDF or view online for FREE

Model
CCD-TR315 CCD-TR416 CCD-TR416PK CCD-TR516 CCD-TR516PK CCD-TR716 CCD-TRV16 CCD-TRV16PK CCD-TRV36 CCD-TRV36PK CCD-TRV43 CCD-TRV46 CCD-TRV46PK (serv.man2)
Pages
127
Size
17.11 MB
Type
PDF
Document
Service Manual
Brand
Device
Movie
File
ccd-tr315-ccd-tr416-ccd-tr416pk-ccd-tr516-ccd-tr51.pdf
Date

Sony CCD-TR315 / CCD-TR416 / CCD-TR416PK / CCD-TR516 / CCD-TR516PK / CCD-TR716 / CCD-TRV16 / CCD-TRV16PK / CCD-TRV36 / CCD-TRV36PK / CCD-TRV43 / CCD-TRV46 / CCD-TRV46PK (serv.man2) Service Manual ▷ View online

5-12
Address
Initial
Remark
Value
Address
Initial
Remark
Value
5. E Page Table
Note 1:
Fixed data-1 : Initialized data.
( Refer to “1. Initializing the D,E,F Page Data”.)
Fixed data-2 : Modified data.
(Refer to “2. Modification of D, E, F Page Data”).
Note 2:
See “1-5. LCD SYSTEM ADJUSTMENT”.
00
Fixed data-1
01
02
03
04
05
06
07
08
09
0A
Fixed data-2
0B
0C
Fixed data-1
0D
0E
0F
10
11
12
13
14
15
16
17
18
19
1A
1B
1C
1D
1E
1F
20
Fixed data-2
21
Fixed data-1
22
23
24
25
26
27
28
29
2A
2B
Fixed data-2
2C
2D
2E
2F
Fixed data-1
30
31
32
33
34
35
36
37
38
Fixed data-1
39
3A
3B
Fixed data-2
3C
Fixed data-1
3D
3E
3F
40
41
42
43
44
45
46
47
48
49
4A
4B
4C
4D
4E
4F
Fixed data-2
50
Fixed data-1
51
52
53
Fixed data-2
54
55
Fixed data-1
56
57
58
59
Fixed data-2
5A
5B
Fixed data-1
5C
Fixed data-2
5D
Fixed data-1
5E
5F
60
Fixed data-2
61
62
63
Fixed data-1
64
Fixed data-2
65
66
67
Fixed data-1
68
69
6A
6B
Fixed data-2
6C
6D
Fixed data-1
6E
Fixed data-2
6F
70
Fixed data-1
71
TR model:Fixed data-1/TRV model:Fixed data-2
72
Fixed data-1
73
Fixed data-2
74
Fixed data-1
75
Fixed data-2
76 to 99
Fixed data-1
5-13
Address
Initial
Remark
Value
Address
Initial
Remark
Value
9A
Fixed data-2
9B
Fixed data-1
9C
Fixed data-2
9D
Fixed data-1
9E
9F
A0
Fixed data-2
A1
Fixed data-1
A2
TR model:Fixed data-1/TRV model:Fixed data-2
A3
Fixed data-2
A4
Fixed data-1
A5
A6
A7
A8
A9
AA
AB
AC
AD
AE
AF
B0
B1
B2
B3
B4
B5
B6
B7
B8
B9
BA
Fixed data-2
BB
BC
BD
BE
BF
TR model : Fixed data-1
C0
TRV model : Fixed data-2
C1
C2
VCO adj. (Color EVF)
C3
Bright adj. (Color EVF)
C4
Contrast adj. (Color EVF)
C5
White balance adj. (Color EVF)
C6
White balance adj. (Color EVF)
C7
Fixed data-2 : Color EVF model
C8
Fixed data-1 : B/W EVF model
C9
CA
CB
CC
Backlight consumption current adj. (Color EVF)
CD
Fixed data-1
CE
CF
Note 2
Bright adj. (LCD)
D0
Note 2
Color adj. (LCD)
D1
Note 2
White balance adj. (LCD)
D2
Note 2
White balance adj. (LCD)
D3
Note 2
Contrast adj. (LCD)
D4
Note 2
D range adj. (LCD)
D5
Note 2
V-COM level adj. (LCD)
D6
Note 2
VCO adj. (LCD)
D7
Note 2
V-COM adj. (LCD)
D8
Fixed data-1
D9
Fixed data-1
DA
DB
TR model:Fixed data-1/TRV model:Fixed data-2
DC
Fixed data-1
DD
DE
DF
E0
E1
E2
E3
E4
E5
E6
E7
E8
E9
EA
Fixed data-2
EB
Fixed data-1
EC
ED
EE
EF
Fixed data-2
F0
Fixed data-1
F1
F2
F3
Fixed data-2
F4
Fixed data-1
F5
F6
F7
F8
F9
FA
FB
FC to FF
5-14
1-3. CAMERA SYSTEM ADJUSTMENTS
Before perform the camera system adjustments, Check that the
specified value of “28MHz Origin Oscillation Adjustment”, “Y OUT
level Adjustment” and “C OUT level Adjustment” of “VIDEO
SYSTEM ADJUSTMENT” are satisfied.
1. G-CAM flip Adjustment
Set the color reproduction conditions to optimum.
Subject
Color bar chart standard picture frame
Measurement Point
Display data of page 1 of the adjusting
remote commander (Note 1)
Measuring Instrument
Adjustment Page
F
Adjustment Address
21
Note 1.
Displayed data of page 1 of the adjusting remote com-
mander.
1 : XX : XX
n S2
n S1
Note 2.
[   ] : CCD-TR516/TR516PK
CCD-TRV36/TRV36PK
< > : CCD-TR716
CCD-TRV43/TRV46/TRV46PK
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 0, address: 03, and set data: 16.
3) Select page 1 of the adjusting remote commander, and compare
the higher 2 digits (S1) and lower 2 digits (S2) of the 4-degits
display data.
When S1<S2
Perform steps 4) onwards.
When S1  S2
Perform steps “Processing after Completing Adjustments”.
4) Select page: F, address: 21, set data:
when the read data is [52] or <50>, change to [D2] or <D0>, and
the read data is [D2] or <D0>, change to [52] or <50>, (initial
value is 52) and press the PAUSE button of the adjusting remote
commander.
Processing after Completing Adjustments
1) Select page: 0, address: 03, and set data: 00.
2) Select page: 0, address: 01, and set data: 00.
5-15
2. HALL Adjustment
For detecting the position of the lens iris, adjust the hall AMP gain
and offset.
Subject
Not required
Measurement Point
DDS display data of LCD or TV monitor
(Note 3)
Measuring Instrument
Adjustment Page
F
Adjustment Address
2F, 30
Specified Value
7E to 82 during IRIS OPEN (Note 1)
13 to 17 during IRIS CLOSE (Note 2)
Note 1:
Select page: 2, address: 01, set data: 01, and press the
PAUSE button of the adjusting remote commander.
Note 2:
Select page: 2, address: 01, set data: 03, and press the
PAUSE button of the adjusting remote commander.
Note 3:
DDS display data of LCD or TV monitor.
00 00XX
n Object data
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 0, address: 03, and set data: 03.
3) Select page: D, address: 11, set data: 02, and press the PAUSE
button of the adjusting remote commander.
4) Select page: 2, address: 01, set data: 03, and press the PAUSE
button.
5) Select page: F, address: 30, set data: 80, and press the PAUSE
button.
6) Select page: F, address: 2F, set data: 40, and press the PAUSE
button.
7) Read the DDS display data (the bottom two digits of the display
data at the bottom right of the LCD display or the TV monitor),
and this data is named K
2
.
8) Select page: F, address: 2F, set data: 30, and press the PAUSE
button.
9) Read the DDS display data, and this data is named K
1
.
10)Select page: 2, address: 01, set data: 01, and press the PAUSE
button.
11)Read the DDS display data, and this data is named W
1
.
12)Select page: F, address: 2F, set data: 40, and press the PAUSE
button.
13)Read the DDS display data, and this data is named W
2
.
14)Convert W
1
, W
2
, K
1
, K
2
, to decimal notation, and obtain W
1
' ,
W
2
' , K
1
' , K
2
'. (Refer to Table 5-1-2. “Hexadecimal notation -
decimal notation conversion table”.)
15)Calculate X
1
' using the following equations (decimal notation
calculation).
A’= W
2
'+ K
1
'– W
1
'– K
2
'
Equation 1
B’= W
1
' – K
1
'
Equation 2
X
1
'=[1696+(48 x A’)–(16 x B’)] / A’
Equation 3
16)Convert X
1
' to hexadecimal notation, and obtain X
1
.
(Round off to one decimal place)
17)Select page: F, address: 2F, set data: X
1
, and press the PAUSE
button.
18)Select page: 2, address: 01, and set data: 01, and press the PAUSE
button.
19)Select page: F, address: 30, change the data and adjust the DDS
display data to “80”.
20)Press the PAUSE button of the adjusting remote commander.
21)Select page: 2, address: 01, and set data: 03, and press the PAUSE
button.
22) Read the DDS display data, and this data is named K
0
. If K
0
 lies
within the “13” to “17” range, perform “Processing after com-
pleting adjustments”. If it is lies outside the range, perform the
following adjustments.
23) Convert K
0
 to decimal notation, and obtain K
0
'.
24) Calculate X
2
' using the following equations (decimal notation
calculation).
C’= 128 – B’– K
0
'
Equation 4
X
2
'=[(106 – B’) x ( X
1
' – 48)+(48 x C’)] / C’
Equation 5
( X
1
' and B’ are values obtained from equations 2) and 3) )
25) Convert X
2
' to hexadecimal notation, and obtain X
2
.
(Round off to one decimal place)
26) Select page: F, address: 2F, set data: X
2
, and press the PAUSE
button.
27) Select page: 2, address: 01, set data: 03, and press the PAUSE
button.
28) Select page: F, address: 30, change the data and adjust the DDS
display data to “15”.
29) Press the PAUSE button of the adjusting remote commander.
30) Select page: 2, address: 01, set data: 01, and press the PAUSE
button.
31) Check the DDS display data lies within the “7E” to “82” range.
Processing after Completing Adjustments
1) Select page: D, address: 11, and set data: 00, and press the PAUSE
button.
2) Select page: 0, address: 01, and set data: 00.
3) Select page: 2, address: 01, and set data: 00, and press the PAUSE
button.
4) Select page: 0, address: 03, and set data: 00.
Page of 127
Display

Click on the first or last page to see other CCD-TR315 / CCD-TR416 / CCD-TR416PK / CCD-TR516 / CCD-TR516PK / CCD-TR716 / CCD-TRV16 / CCD-TRV16PK / CCD-TRV36 / CCD-TRV36PK / CCD-TRV43 / CCD-TRV46 / CCD-TRV46PK (serv.man2) service manuals if exist.