— 5 —
SERVICE NOTE
1.
POWER SUPPLY DURING REPAIRS
In this unit, about 5 seconds after power is supplied (4.2V) to the battery terminal using a regulated power supply, the power is shut off so that
the unit cannot operate.
This following three methods are available to prevent this. Take note of which to use during repairs.
Method 1.
Decrease the voltage to 3Vdc.
Method 2.
Connect the servicing remote commander RM-95 (J-6082-053-B), and set the remote commander switch to the “ADJ” side.
Method 3.
Use the AC power adaptor.
— 6 —
SELF-DIAGNOSIS FUNCTION
1.
SELF-DIAGNOSIS FUNCTION
When problems occur while the unit is operating, the self-diagnosis
function starts working, and displays on the LCD display what to
do. This function consists of two display; self-diagnosis display and
service mode display.
Details of the self-diagnosis functions are provided in the Instruction
manual.
2.
SELF-DIAGNOSIS DISPLAY
When problems occur while the unit is operating, the counter of the
LCD display consists of an alphabet and 4-digit numbers, which
blinks at 3.2 Hz. This 5-character display indicates the “repaired
by:”, “block” in which the problem occurred, and “detailed code”
of the problem.
1 1
3 1
C
Repaired by:
Refer to 
"3. Self-diagnosis Code Table".
Indicates the appropriate
step to be taken.
E.g.
31
32
Block
Detailed Code
Blinks at 3.2Hz
C : Corrected by customer
H : Corrected by dealer
E : Corrected by service
engineer
LCD display
C : 3 1 : 1 1
• Reload the video cartridge.
• Turn on power again.
• After leaving the machine as
  it is for about one hour, perform
  operations from the beginning.
3.
SELF-DIAGNOSIS CODE TABLE
C
C
C
C
Block
Function
1
2
2
2
2
3
3
1
3
2
Detailed
Code
8
0
0
0
0
0
Symptom/State
Format of the video cartridge is different.
Video head is dirty.
Non-standard battery is used.
Self-diagnosis Code
Repaired b
y
:
Correction
Use the video cartridge of correct format.
Use the InfoLITHIUM battery.
• Load the video cartridge again, and perform operations from
the beginning.
• Remove the battery or power cable, connect, and perform
operations from the beginning.
• After leaving the machine as it is for about one hour, perform
operations from the beginning.
1-1
CCD-CD1/CR1E
SECTION 1
GENERAL
This section is extracted from
instruction manual. (CCD-CR1E)
1-2
Page of 112
Display