SDM-S71(E)
2-2
2-2. FUNCTIONAL ALIGNMENT (2)
This section describes the functional adjustment 
procedure (using a color meter) of this unit.
Setup 
 
1. Prepare timing and pattern data for a signal generator 
according to the Sony timing specifications.
2. Connect a monitor video cable to the signal generator.
3. Put Topcon 50 cm away from the monitor, specify it 
vertically in the center of the display, and adjust 
the focus to the optimum level using an eyepiece.
4. Put the monitor and Topcon in a light-shielded room.
5. Set up [SERVICE MODE] of the monitor.
Operation
   
Data is manually set to improve the productivity. 
 The brightness and contrast are set to 50 and 70, 
respectively.  After that, the default data of  
the color temperature to be adjusted is set.
Warm  up  time 
Warm up for 30 minutes before performing 
any adjustment.
Color Adjustm ent 
1. 9300K color adjustment 
--Center adjustment-- 
a. Click "Color Temperature" as " 9300". 
b. Use a 40% IRE white video field in the primary 
mode.
c. Confirm that the "backlight" register data is 0
(100%).
d. Click "Refresh". 
Refer to Table 1 in 2-4 for the default data of 
color adjustment.
e. Adjust "sub_brt_B" to secure the color 
temperature.
    Refer to Table 2 in 2-4 for specifications.
f. Click "Save this color" for a color save at 9300K.
2. 5000K color adjustment 
a. Click "Color Temperature" as "5000". 
b. Repeat the adjustment procedure as steps b to f 
at 9300K.
3. 6500K
 
color adjustment 
a. Click "Color Temperature" as "6500". 
b. Repeat the adjustment procedure as steps b to f 
at 9300K.
 Geometry  Adjus tment 
Adjust "Pitch" to make the screen performance optimum.
2. Adjust "Phase" to make the screen performance optimum.
3. Adjust "H position" to make the screen center horizontal.
4. Adjust "V position" to make the screen center vertical.
5. Repeat steps 1 to 4 to make the picture performance 
optimum.
6. Repeat steps 1 to 5 to secure the current timing of the user.
1. 
SDM-S71(E)
2-3
2-3. W/B ALIGNMENT PROCEDURE
A. Measurement Condition:
- Measurement point: Center of screen
- Measurement distance: 50 cm
- Measurement Angle: 90
B. Measurement equipment:
- Color Analyzer: Minolta CS-1000 or equivalent
- Signal Generator: VG-828D or equivalent
C. Alignment Procedure:
Alignment Procedure
Parameter Setting & Specification
1. Aging: 30 minutes or more
Burn-in mode: press "BRT"+"OK" then "Power ON"
2. Enter the “Service Mode”.
Service mode: press "
"+"
" then "Power ON"
3. RGB reset
 Maintains the configuration RGB reset.
4. Initial Data Setting:
a. Brightness: 50
b. Contrast: 70
c. Sub-BRT (R/G/B): 26
d. Sub-CONT (R/G/B): 128
5. Input gray raster pattern
30 IRE (1280*1024, 80K/75Hz)
6. Adjust White Balance (9300K, 6500K & 5000K) and Luminance
(10 nits @ SONY CS-1000) by Sub-BRT
9300K
6500K
5000K
Tolerance
x
0.2838
0.3132
0.3450 }0.003
Remark: In normally, adjust G for Luminance (Y), adjust R for x and adjust
B for y.
y
0.2981
0.3297
0.3580 }0.003
Y
10
10
10 }0.7
7. All mode recall
All mode recall:
press"CONTRAST"
"Power ON"
+"OK" then
SDM-S71(E)
2-4
2-4. TABLE1 & 2
Table 1: Default data for analog color adjustment 
 
Color 9300K 6500K 5000K 
Brightness (G) 
50
30
50
Contrast (G) 
70 
70
70
Sub-Brt-R 30 
33 
37
Sub-Brt-G 32
32
32
Sub-Brt-B 26
18
12
Sub-Cont-R 128
128 
128 
Sub-Cont-G 128 
128 
128 
Sub-Cont-B 128 
128 
128 
Table 2: Specifications for color adjustment 
 
Color 
Y (35% IRE) 
9300 0.2838 
0.2981 
10 
nit 
6500 0.3132
0.3297 
10 
nit 
5000 0.3450 
0.3580 
10 
nit 
Tole 
± 0.003
± 0.003
± 0.7
Y: Luminance measurements are in cd/m
2
SDM-S71(E)
2-5
2-5. TIMING SPECIFICATION
PRESET MODE 
MODE 1 
MODE 2 
MODE 3 
MODE 4 
MODE 5 
MODE 6 
MODE 7 
MODE 8 
SIGNAL MODE 
VESA 60Hz 
MAC 13” 
VESA 75Hz 
VESA 85Hz 
VESA 70Hz 
VESA 60Hz 
VESA 75Hz 
VESA 85Hz 
RESOLUTION 
640 X 480 
640 X 480 
640 X 480 
640 X 480 
720 X 400 
800 X 600 
800 X 600 
800 X 600 
DOT CLOCK 
25.175 MHz 
30.240 MHz 
31.500 MHz 
36.000 MHz 
28.350 MHz 
40.000 MHz 
49.500 MHz 
56.250 MHz 
HORIZONTAL usec usec usec usec usec usec usec usec 
H. 
TOATL 
31.778 28.571 26.667 23.111
31.746 26.400 21.333 18.631
H. 
SYNC 
3.813 2.116 2.032 1.556 2.540 3.200 1.616 1.138
H. 
BP 
1.907 3.175 3.810 2.222
3.175 2.200 3.232 2.702
H. 
ACTIV 
25.422 21.164 20.317 17.778
25.397 20.000 16.162 14.222
VERTICAL 
msec msec
 
msec
 
msec
 
msec
 
msec
 
msec
 
msec
 
V. TOTAL 
16.683 15.000 13.333 11.764
14.254 16.579 13.333
11.756
V. SYNC 
0.064 0.086 0.080 0.069
0.095 0.106 0.064
0.056
V. BP 
1.049 1.114 0.427 0.578 1.079 0.607 0.448 0.503
V. ACTIV 
15.253 13.714 12.800 11.093
12.698 15.840 12.800
11.179
H/V 
POLARITY 
N/N N/N N/N  N/N N/P  P/P  P/P  P/P 
PRESET MODE 
MODE 9 
MODE 10 
MODE 11 
MODE 12 
MODE 13 
SIGNAL MODE 
PMAC 16” 
VESA 60Hz 
VESA 70Hz 
VESA 75Hz 
  
75Hz 
RESOLUTION 
832 X 624 
1024 X 768 
1024 X 768 
1024 X 768 
1024 X 768 
DOT CLOCK 
57.285 MHz 
65.000 MHz 
75.000 MHz 
78.750 MHz 
94.500 MHz 
HORIZONTAL usec usec usec usec usec 
H. 
TOATL 
20.110 20.677 17.707 16.660 14.561 
H. 
SYNC 
1.117 2.092 1.813 1.219 1.016
H. 
BP 
3.910 2.462 1.920 2.235 2.201 
H. 
ACTIV 
14.524 15.754 13.653 13.003 10.836
VERTICAL 
msec msec
 
msec
 
msec
 
msec
 
V. TOTAL 
13.413 16.666 14.272 13.328 11.765 
V. SYNC 
0.060 0.124 0.106 0.050 0.044 
V. BP 
0.744 0.600 0.513 0.466 0.524 
V. ACTIV 
12.549 15.880 13.599 12.795 11.183 
H/V 
POLARITY 
N/N N/N N/N  P/P  P/P 
MODE 14 
MODE 15
MODE 16
PMAC 19”
MAC
 
WS
 
1024 X 768 
1152 X 870
1152 X 900
80.000 MHz 
100.000 MHz 
92.940 MHz 
usec usec usec 
16.600
14.560 16.182
1.200
1.280
1.377
2.200
1.440
2.087
12.800
11.520 12.395
msec
 
msec
 
msec
 
13.346
13.322 15.163
0.050
0.048 0.065 
0.498
0.568 0.502
12.749
12.667 14.564
N/N N/N 
N/N 
VESA
Page of 35