Sony SDM-S51R Service Manual ▷ View online
SDM-S51R(E)
2-2
2-2. TIMING SPECIFICATION
MODE FOR CUSTOMER
VESA 60Hz
RESOLUTION
1024
X
7 6 8
CLOCK
65.000
MHZ
-- HORIZONTAL --
H-FREQ
48.363
kHz
usec
dots
H. TOTAL
20.677
1344
H. BLK
4.923
0
320
H. FP
0.369
24
H. SYNC
2.092
136
H. BP
2.462
160
H. ACTIV
15.754
1024
-- VERTICAL --
V. FREQ(HZ)
60.004
Hz
msec
lines
V. TOTAL
16.666
806
V. BLK
0.786
38
V. FP
0.062
3
V. SYNC
0.124
6
V. BP
0.600
29
V. ACTIV
15.880
768
- - S Y N C - -
INT(G)
EXT(H/V)/POLARITY
YES
N/N
EXT(CS) /POLARITY
Serration
NO
NO
NO
SYNC LEVEL
TTL
V
-- VIDEO --
VIDEO LEVEL
0.700
Vp-p
SET UP
0
V
-- OTHERS --
INT/NON INT
NON INT
SIZE(15")
304 X 228
mm
mm
mm
SIZE(17")
-
SIZE(18")
-
#OF GRIDS
16
X 12
DOTS & LINES/GRID
64
X 64
EDID DATA
COMMENTS
- SONY SG SETTING
-OTHERS 35IRE
Adj Signal
SDM-S51R(E)
2-3
2-3. WHITE BALANCE ADJUSTMENT
<Equipments required>
Signal generator: VG819 or equivalent (Be sure to confirm the output level of the analog RGB out 75 ohm terminated.)
Color analyzer: MINOLTA CS1000 or equivalent
Color analyzer: MINOLTA CS1000 or equivalent
<Preparation>
Confirm the center of screen by feeding the cross pattern, and set the color analyzer at the 50cm distance from the center of the screen.
Set the monitor to Aging mode for 30 minutes or more.
Set the monitor to Aging mode for 30 minutes or more.
<Setting>
On the service mode, set Bright=50, Contrast=70 and Backlight=100.
Be sure to set the menu display position off from the mesuring point.
Feed the attached specification timing signal to the monitor.
Be sure to set the menu display position off from the mesuring point.
Feed the attached specification timing signal to the monitor.
<Adjusting>
1. While feeding the all white signal, select and execute "INITIAL EEPROM" command in service menu.
2. Switch the signal to the 35IRE all gray, select "COLORTEMP 9300K". (The signal output level should be 0.245V at 75ohm terminated.)
3. Fix the B data of SUB CONTRAST, adjust the R and G data to the specified value below. (Be sure to adjust by reducing the R and G data.)
2. Switch the signal to the 35IRE all gray, select "COLORTEMP 9300K". (The signal output level should be 0.245V at 75ohm terminated.)
3. Fix the B data of SUB CONTRAST, adjust the R and G data to the specified value below. (Be sure to adjust by reducing the R and G data.)
9300K x=0.283
±0.003 y=0.298±0.003
Note: In the fine adjustment, in case of the B adjustment is needed, be sure to adjust within several steps.
4. Continuously feeding the 35IRE all gray signal, select "COLORTEMP 6500K".
5. Fix the B data of SUB CONTRAST, adjust the R and G data to the specified value below. (Be sure to adjust by reducing the R and G data.)
6500K x=0.313+-0.003 y=0.329+-0.003
4. Continuously feeding the 35IRE all gray signal, select "COLORTEMP 6500K".
5. Fix the B data of SUB CONTRAST, adjust the R and G data to the specified value below. (Be sure to adjust by reducing the R and G data.)
6500K x=0.313+-0.003 y=0.329+-0.003
6. Turn power off to release the service mode.
SDM-S51R(E)
3-1
3-1. CIRCUIT BOARDS LOCATION
SECTION 3
DIAGRAMS
G board
H board
A board
SDM-S51R(E) 4-1
SECTION 4
EXPLODED VIEWS
• Items with no part number and no
description are not stocked because they
are seldom required for routine service.
are seldom required for routine service.
• The construction parts of an assembled
part are indicated with a collation number
in the remark column.
in the remark column.
• Items marked " * " are not stocked since
they are seldom required for routine
service. Some delay should be anticipated
when ordering these items.
service. Some delay should be anticipated
when ordering these items.
The components identified 0
0
marked are
critical for safety.
Replace only with the part number specified.
Replace only with the part number specified.
Les composants identifiés par la marque
sont critiques pour la sécurité.
Ne les remplacer que par une pièce portant
le numéro spécifié.
sont critiques pour la sécurité.
Ne les remplacer que par une pièce portant
le numéro spécifié.