DOWNLOAD Sony SDM-G96D / SDM-G96X Service Manual ↓ Size: 988.18 KB | Pages: 20 in PDF or view online for FREE

Model
SDM-G96D SDM-G96X
Pages
20
Size
988.18 KB
Type
PDF
Document
Service Manual
Brand
Device
Monitor
File
sdm-g96d-sdm-g96x.pdf
Date

Sony SDM-G96D / SDM-G96X Service Manual ▷ View online

SPEAKER EXCHANGE PROCESS 
 
 
 
 
<Attention of Speaker wiring>
 
 
 
 
 
 
 
                                                                                          13                                             
SDM-G76D , SDM-G96D/X (E)        
 
BLOCK DIAGRAM   
 
 
 
 
DESCRIPTION OF BLOCK DIAGRAM 
 
 
 
                                                                                          14                                             
SDM-G76D , SDM-G96D/X (E)        
 
LIPS Board Block Diagram 
 
 
Operation Description LIPSDESCRIPTION OF BLOCK DIAGRAM 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
                                                                                          15                                             
SDM-G76D , SDM-G96D/X (E)        
 
ADJUSTMENT 
 
1. Procedures of how to go to service mode. 
1) Enter the service mode of this unit by turning on the 
power while pressing “down” key and the "power" 
key simultaneously. 
2) Press "MENU" key----MAINTAIN. 
3) Press the “Down” or “Up” key to select the icon “S” 
and press "OK" key to enter into the service menu. 
4) Select the desired function. 
5) Press the "MENU" key to exit OSD. 
6) Turn off the power and then turn on it again. The 
monitor then enters the normal mode. 
To enter the service again, repeat the procedure 
described above. 
Note 
W/B readjustment is required after the panel, board 
and microcomputer are replaced. However, be sure to 
perform aging for more than 30 minutes for RGB reset 
before W/B adjustment. 
 
 
2. Setup 
1) Prepare timing and pattern data for a signal 
generator according to the Sony timing 
specifications. 
2) Connect a monitor video cable to the signal 
generator. 
3) Put Color Analyzer (ex. CA-210) 50cm away from 
the monitor, specify it vertically in the center of the 
display, and adjust the focus to the optimum level 
using an eyepiece. 
4) Put the monitor and Color Analyzer (ex. CA-210) in a 
light-shielded room. 
5) Set up [SERVICE MODE] of the monitor. 
 
 
3. Operation 
Data is manually set to improve the productivity. The 
brightness, contrast, and backlight are set to 50, 90 
and 100 respectively. After that, the default data of the 
color temperature to be adjusted is set. 
 
 
4. Warm up time 
Warm up for 30 minutes before performing any 
adjustment. 
 
 
 
 
 
5. Adjustment for White Balance 
a. Display five white block and black pattern VGA/ 
60Hz (Input level 0.73V). 
b. Set up [SERVICE MODE]. 
c. Click “INITIAL EEPROM” and again setup Service 
Mode. 
d. Click "WHITE BALANCE" and then select “AUTO”. 
e. Prepare timing and full white pattern. 
 
 
6. 9300K color adjustment 
a. Select "9300K" in "COLOR TEMP" and enter. 
b. Use a 100% (255Gray) IRE white video field in the 
primary (SXGA) mode. 
c. Adjust "SUB CONTRAST" to secure the color 
temperature  
d. Press "MENU" key to exit adjust mode. 
 
 
7. 6500K color adjustment 
a. Select "6500K" in "COLOR TEMP" and enter. 
b. Repeat the adjustment procedure as steps b to d at 
9300K.   
 
 
8. SRGB color adjustment 
a. Select "SRGB" in "COLOR TEMP" and enter. 
b. Adjust “SUB CONTRAST” value to the value of 
6500K RGB.   
 
 
<<Specification of WB adjustment>>
x (±15) y (±15)
9300K
290
316
350 +-70
6500K
306
326
370 +-70
sRGB
306
326
180 +-40
9300K
290
326
350 +-70
6500K
311
336
370 +-70
sRGB
311
336
180 +-40
9300K
295
320
370 +95/-70
6500K
308
330
370 +95/-70
sRGB
318
338
180 +-50
100IRE
17" AUO
17" LPL
19" AUO
Panel
Model
 
 
 
 
 
 
 
 
 
 
 
 
 
                                                                                          16                                             
SDM-G76D , SDM-G96D/X (E)        
 
Page of 20
Display