CPD-G520
2-6
2-8. HARNESS  LOCATION
CN602
CN601
CN604
CN1102
CN312
CN311
CN318
CN319
CN320
CN316
CN315
CN303
CN1103
CN1400
CN1500
CN1401
CN605
CN701
CN501
CN1601
CN1600
CN1602
CN2
CN1
CN1
5P
CN3
CN1003
CN904
CN2601
4P
4P
D board
A1 board
N board
L2 board
Magnetic sensor
US board
 #4
[
AEP
, NH, SH, EQ models]
H1 board
Picture tube
AC inlet (3P)
CPD-G520
SECTION  3
SAFETY  RELATED  ADJUSTMENT
3-1
HV Regulator
Circuit Check
HV Protector
Circuit Check
Beam Current
Protector Circuit
Check
When replacing or repairing the shown below table, the
following operational checks must be performed as a
safety precaution against X-rays emissions from the unit.
Part Replaced (
[)
RV901
HV ADJ
*
Confirm one minute after turning on the power.
a) HV Regulator Circuit Check
1) Turn the RV901 slowly, and adjustment so that high
voltage is in the specified range.
[Specification]: 27.00 ± 0.05 kV
2) Check that the voltage of D912 cathode on the D
board is 17.0 V or more.
b) HV Protector Circuit Check
1) Using external DC Power Supply, apply the voltage
shown below between cathode of D912 and GND,
and check that the RASTER disappers.
[Specification]: 19.95 + 0.00/– 0.05 V
c) Beam Current Protector Circuit Check
1) Connect constant current source to a section between
T901 (FBT) qa pin and GND, and check that the
RASTER disappers when the specified current flows
to the qa pin.
[Specification]: 2.12 + 0.00/– 0.01 mA
Part Replaced (
])
D Board C925, IC901, R901,
R902, R905, R924,
R925, R926, RV901,
T901 (FBT)
• Mounted D Board
D Board C920, C923, D911,
D912, R903, R917,
R918, R919, R920,
R923, T901 (FBT)
• Mounted D Board
N Board IC1001, RB1001
• Mounted N Board
D Board C930, D917, R921,
R932, R933, R935,
T901 (FBT)
• Mounted D Board
N Board IC1001, RB1001
• Mounted N Board
CPD-G520
SECTION  4
ADJUSTMENTS
Landing Rough Adjustment
1. Display all white pattern (or black dot pattern).
2. Set contrast to 255.
3. Display green plain pattern.
4. Side back DY and roughly adjust green plain pattern to be
centered on the useful screen with Purity Magnet.
5. Adjust DY tilt.
Note: Set ROTATION to 128 and LCC_NS to 128 when
adjusting DY tilt.
6. LIghtly tighten the DY screw.
Landing Fine Adjustment
Note: (1) After adjust W/B (9300k), measure the average of
IK with all white video input, while CONTRAST is
maximum and BRIGHTNESS is center. And
adjustment shall be made so that the miss-landing
become least after aging 2H with the IK 30% of
measured value shown above.
(2) The magnetic field shall be BH = 0.
(3) When adjusting at other than BH = 0, calculate the
shifted value from BH = 0.
1. Put the monitor in helmholz coil.
2. Set as follows;
LCC_SW = 0
(LCC Correction Current = 0)
FUNCTION_SW bit1 =
(Auto Degauss = On)
CONTRAST = 255
3. Display green plain pattern.
4. Degauss the iron part of chassis with a hand degausser and
degauss coil.
5. Degauss CRT face with a hand degausser again.
6. Input AC 230V to AC IN and turn the monitor off and on.
Then auto-degauss works.
7. Reset FUNCTION_SW bit1 to 0 (auto-degauss = off)
8. Degauss CRT face with a hand degausser again.
9. Attach wobbling coil to the specified place on CRT neck.
10. Put on landing sensor to CRT face.
11. Set LCC_SW to 12.
12. With landing checker, adjust DY position, purity, DY center
and landing of the 4 corners.
13. Read VX and VY value which are the read out of magnetic
sensor, and write to "LCC_VX_REF" and "LCC_VY_REF".
14. Adjust landing by LCC_NS, LCC_LT, LCC_LB, LCC_RT,
and LCC_RB. Adjustment of registers shall be limited
within the following range.
LCC_NS: 128 ± 15
LCC_LT, LCC_LB, LCC_RT, and LCC_RB: 128 ± 40
Set LCC_SW to 13, and Perform Service Save.
17. Adjust top and bottom pins correction VR.
18. Adjust the horizontal trapezoid distortion by DY horizontal
trapezoid correction VR.
19. Check landing at each corner and in case not in specification,
adjust landing of 4 corners with "LCC_NS", "LCC_LT",
"LCC_LB", "LCC_RT", and "LCC_RB". The limitations of
registers are shown below.
LCC_NS: 128 ± 15
LCC_LT, LCC_LB, LCC_RT, and LCC_RB: 128 ± 40
20. Remove the sensor and wobbling coil.
21. Switch signals to R, G, and B, and then check that the pure
colors have good color purity.
22. Fix purity magnets with white paint.
4-1
15. Tighten DY screw within specified torque, and auto-
degauss.
Note: Torque 22 ± 2 kgcm (2.2 ± 0.2Nm)
16. Adjust the vertical angle of DY to make top and bottom pins
equal (a = b). The horizontal angle shall not be changed
(straight). Settle DY upright without leaning, and insert
wedges firmly so that DY shall not move.
Note: Hand degauss must be used on stand-by or power-off condition.
This model has an automatic earth magnetism correction function by using an earth magnetism sensor
and a LCC coil. When using a hand degauss while monitor (LCC coil) is being operated, it sometimes
gets magnetized, and the system may not work properly as a result.
 ± 6
 ± 6
 ± 6
 ± 6
 ± 6
 ± 6
 ± 6
 ± 6
 ± 6
(µm)
10
10
10
10
7
10
10
10
10
(µm)
The red and blue must be within
the specification given right with
respect to the green.
A difference between red and blue
must be within the specification
given right.
<Specifications>
Adjust so that the green is within
the specification given right.
4 corner adjust target : within ± 1
0 ± 3 0 ± 7.5 0 ± 3
0 ± 3 0 ± 7.5 0 ± 3
0 ± 3 0 ± 7.5 0 ± 3
(µm)
a
b
c
d
<How to place wedge>
Green plain crosshatch pattern
a and b should be equal.
c and d should be equal.
Plaster RTV to both sides for the upper wedge.
Make sure that they settle inside DY.
Plaster RTV to one side for other wedges.
CPD-G520
4-2
Connect the communication cable of the computer to the connector located on the D board. Run the service software and then follow
the instruction.
IBM AT Computer
as a Jig
1-690-391-21
1
A-1500-819-A
Interface Unit
2
*The parts above (                ) are necessary for DAS adjustment.
1
3
D-sub
(9 Pin [female])
mini Din
(8Pin)
4 Pin
3-702-691-01
Connector Attachment
3
To BUS CONNECTOR
4 Pin
4 Pin
Convergence Rough Adjustment
(1) Display white crosshatch pattern.
(2) Pile the convex parts of 6-pole magnet for convergence
together.
(3) Roughly adjust H.CONV and V.CONV with 4-pole magnet.
White Balance Adjustment Specification
1. 9300 K
x = 0.283 ± 0.005
y = 0.298 ± 0.005
(All White)
2. 6500 K
x = 0.313 ± 0.005
y = 0.329 ± 0.005
(All White)
3. 5000 K
x = 0.346 ± 0.005
y = 0.359 ± 0.005
(All White)
Vertical and Horizontal Position and Size
Specification
Focus adjustment
Adjust the focus volume 1 and 2 for the optimum focus.
Convergence Specification
B
a
a     1.8 mm
b     1.8 mm
a
b
b
A
MODE
A
B
4 : 3
388
291
B
A
A
0.20 mm
B
0.24 mm
V
XBV
XCV
B
R
B
R
R
B
B
R
R
B
B
TLV
TLH
YBH
YCH
R B
R B
H.TRAP
TB-PIN
TLH
XCV
Purity
4-pole magnet
6-pole magnet
2-pole magnet
Focus 1
Focus 2
FBT