Sony CPD-E540 Service Manual ▷ View online
CPD-E540 (E)
1-6
1-7. PICTURE TUBE REMOVAL
4
Picture tube
1
Anode cap (Refer to 1-8)
2
A1 board (C block)
3
Neck assembly
CN1
CN2
CN3
CN2
GND
CPD-E540 (E)
1-7
3
When one side of the rubber cap is
separated from the anode button, the
anode-cap can be removed by turning up
the rubber cap and pulling up it in the
direction of the arrow
separated from the anode button, the
anode-cap can be removed by turning up
the rubber cap and pulling up it in the
direction of the arrow
c
.
•
HOW TO HANDLE AN ANODE-CAP
1
Don’t scratch the surface of anode-caps with sharp shaped
material!
material!
2
Don’t press the rubber hardly not to damage inside of anode-
caps!
A material fitting called as shatter-hook terminal is built in the
rubber.
caps!
A material fitting called as shatter-hook terminal is built in the
rubber.
3
Don’t turn the foot of rubber over hardly!
The shatter-hook terminal will stick out or damage the rubber.
The shatter-hook terminal will stick out or damage the rubber.
•
REMOVAL OF ANODE-CAP
NOTE: Short circuit the anode of the picture tube and the anode cap to the metal chassis, CRT shield or carbon painted on the CRT, after
removing the anode.
•
REMOVING PROCEDURES
1
Turn up one side of the rubber cap in the
direction indicated by the arrow
direction indicated by the arrow
a
.
2
Using a thumb pull up the rubber cap
firmly in the direction indicated by the
arrow
firmly in the direction indicated by the
arrow
b
.
a
b
c
Anode Button
CPD-E540 (E) 1-8
1-8. HARNESS LOCATION
CN602
CN601
CN604
CN1102
CN312
CN311
CN318
CN319
CN320
CN316
CN315
CN303
CN1103
CN1400
CN1401
CN701
CN501
CN1601
CN1600
CN1602
CN2
CN1
CN1
CN3
CN1003
CN904
4P
4P
D board
A1 board
N board
L2 board
H1 board
Picture tube
AC inlet (3P)
CPD-E540 (E)
2-1
SECTION 2
SAFETY RELATED ADJUSTMENT
HV Regulator
Circuit Check
Circuit Check
HV Protector
Circuit Check
Circuit Check
When replacing or repairing the shown below table, the
following operational checks must be performed as a
safety precaution against X-rays emissions from the unit.
Part Replaced (
[)
RV901
HV ADJ
*
Confirm one minute after turning on the power.
a) HV Regulator Circuit Check
1) Turn the RV901 slowly, and adjustment so that high
voltage is in the specified range.
[Specification]: 27.00
±
0.05 kV
2) Check that the voltage of D912 cathode on the D
board is 17.0 V or more.
b) HV Protector Circuit Check
1) Using external DC Power Supply, apply the voltage
shown below between cathode of D912 and GND,
and check that the RASTER disappers.
[Specification]: 19.95 + 0.00/– 0.05 V
Part Replaced (
])
D Board C925, IC901, R901,
R902, R905, R924,
R925, R926, RV901,
T901 (FBT)
• Mounted D Board
R925, R926, RV901,
T901 (FBT)
• Mounted D Board
D Board C920, C923, D911,
D912, R903, R917,
R918, R919, R920,
R923, T901 (FBT)
• Mounted D Board
R918, R919, R920,
R923, T901 (FBT)
• Mounted D Board
N Board IC1001, RB1001
• Mounted N Board
Beam Current
Protector Circuit
Check
Protector Circuit
Check
Part Replaced (
])
D Board C930, D917, R921,
R932, R933, R935,
T901 (FBT)
• Mounted D Board
T901 (FBT)
• Mounted D Board
N Board IC1001, RB1001
• Mounted N Board
Click on the first or last page to see other CPD-E540 service manuals if exist.