CPD-220AS
– 13 –
2-6. STAND  BLOCK  REMOVAL
     Screw
     (+BVTP 4 x 16)
4
     Screw
     (+BVTP 4 x 16)
6
     Two screws
     (+BVTT 4 x 10)
3
     Two screws
     (+BVTT 4 x 10)
5
     Stand block
7
     A block
GND
GND
2
     Anode cap
Cushion
Speaker lead
CN501
CN503
CN601
Connector
1
GND
Speaker
lead
2-7. PICTURE  TUBE  REMOVAL
     Picture tube
     Neck assy
     Deflection yoke
     Picture tube shied
     Two tapping 
     screws (5)
2
     Two tapping screws (5)
3
4
5
6
1
GND
Cushion
CPD-220AS
– 14 –
SECTION  3
SAFETY  RELATED  ADJUSTMENT
Part Replaced (
[
)
RV501
HV ADJ
When replacing or repairing the shown below table, the
following operational checks must be performed as a
safety precaution against X-rays emissions from the unit.
Beam Current Protector Check
Using an external DC Power Supply, applying voltage of
7.00 ± 0.05 V between !] pin of FBT (T501) and GND,
and confirm that the vlotage of both ends C519 is with in
the Voltage range shown below.
• Standard voltage : Less than 3.26 V DC
Check Condition
• Input voltage : 240.0 V AC
• Input signal
: Cross hatch at 64.0 kHz
(VESA 1024 x 768)
• Beam control : CONT : 100 %, BRT : 40 %
B+ Voltage Check
Standard voltage : 150.0 ± 2.0 V DC
Check Condition
• Input voltage : 240.0 ± 2.0 V AC
Note : Use NF power supply or make sure that
distortion factor is 3% or less.
• Input signal
: Cross hatch at 64.0 kHz
• Beam control : CONT : 100 %, BRT : 40 %
HV Regulator
Circuit
HV Protector
Circuit
Beam Current
Protector Circuit
Part Replaced (
]
)
D board IC801, C509, C542,
C548, C802, C814,
C815, R538, R539,
R540, R541, R807,
R822, R823, R824,
RV501, T501 (FBT)
D board IC801, IC904, D511,
D515, C515, C516,
C517, C910, R532,
R533, R534, R535,
R996, T501 (FBT)
• Mounted D board
D board IC901, D596, C519,
C528, C549, C904,
R542, R543, R544,
R545, R939
• Mounted D board
*
Confirm one minute later turning on the power.
HV Protector Circuit Check
Confirm that the HV protector circuit works and CRT
screen disappearing when apply the voltage as shown
below between Cathode of D511 on D board and GND
using an external DC Power Supply.
• Standard voltage  :  35.00
V DC
Check Condition
• Input voltage : 240.0 ± 2.0 V AC
• Input signal
: Cross hatch at 64.0 kHz
(VESA 1024 x 768)
• Beam control : CONT : 100 %, BRT : 40 %
+0.00
–0.10
CPD-220AS
– 15 –
SECTION  4
ADJUSTMENTS
Fixing DY with wedges.
“a” and “b” must be equal, and
“c” and “d” must be almost equal.
9.
Adjust vertical swing with vertical pins, and also adjust hori-
zontal swing so that horizontal keystone and vertical tilt are
optimum, then fix with four wedges.
(When fixing DY with wedges, insert wedges completely so
that the DY does not shake.)
Note:
(1) Do not paste more than 2 magnets to one corner.
(2) Paste within 80 to 100 mm from the DY on the diagonal line
of the magnet.
<How to drive in wedges>
Apply a locking agent to the
upper wedges only.
In such a case, apply agent so that
it enters both sides of wedge and
also inside the DY.
10. Check the landing of each corner, and if they do not satisfy
the specification, paste a Disk-Mg onto the funnel and ad-
just.
11. If using the magnet, be sure to demagnetize with the hand
degausser and check.
12. Remove the sensor and wobbling coil.
13. Check that the DY is not tilting, and fix the purity Mg with a
white pen.
Landing Rough Adjustment
1.
Enter the full white signal. (or the full black dots signal)
2.
Set the contrast to “CONT”=MAX.
3.
Make the screen monogreen.
Note: Off the outputs from R ch and B ch of SG.
4.
Reverse the DY, and adjust coarsely the purity magnet (2-
pole Mg) so that a green raster positions in the center of
screen.
The 2-pole Mg adjustment must be done on the DY side (do
not use 2-pole Mg on the neck assy side).
Note: Stack 2-pole Mg on neck assy side with their sides flushed.
Adjust color Knob
to non-color Knob.
5.
Moving the DY forward, adjust so that an entire screen be-
comes monogreen.
6.
Adjust the tilt of DY, and fix lightly with a clamp.
Note: “TILT” shall be set at 0.
Landing Fine Adjustment
1.
Put the set inside the Helmholtz coil.
2.
Input the single green signal.
(Adjust to L/D control brightness)
[L/D control brightness]
Adjust L/D after aging for 2 hours with L/D control bright-
ness
(1) L/D control brightness ......... 1/2 between cool L/D and
hot L/D (Reference : 
Ik =
200 uA)
(2) Practical max brightness ...... 110 cd/m
2
 
Ik = 595 uA
[L/D control specification]
In Y axis : ± 7.5 um
At corners : ± 5.0 um
3.
Demagnetize the CRT surface with the hand degausser , and
perform auto degaussing.
Note: Adjust in a non-magnetic field.
4.
Attach the wobbling coil to the designated part of the CRT
neck.
5.
Pull out the TLH correction piece up to the position where a
stopper is engaged.
6.
Attach the sensor of the landing adjustment unit on the CRT
surface.
7.
Adjust the DY position and purity, and the DY tilt.
For the purity adjustment, use 2-pole Mg on DY side.
8.
Fasten DY with screw.
Note: Torque 22 ±2kg·cm (2.2 ± 0.2 Nm)
Perform auto degaussing.
c
a
b
d
CPD-220AS
– 16 –
A
312 mm
B
MODE
All mode
234 mm
a    1.6 mm
b    1.6 mm
a
B
A
b
B
A
A
0.24 mm
B
MODE
All mode
0.32 mm
IBM AT Computer
as a Jig
1-690-391-21
1
A-1500-819-A
Interface Unit
2
*The parts above (               ) are necessary for DAS adjustment.
1
3
D-sub
(9 Pin [female])
mini Din
(8Pin)
4 Pin
3-702-691-01
Connector Attachment
3
To BUS CONNECTOR
4 Pin
4 Pin
Connect the communication cable of the computer to the connector located on the D board on the monitor.  Run the service software and
then follow the instruction.
Convergence Rough Adjustment
1.
Enter the white crosshatch signal (white lines on black).
2.
Adjust roughly the horizontal and vertical convergence at
four-pole magnet.
3.
Adjust  roughly HMC and VMC at six-pole magnet.
Standard: ± 0.1mm (In the center of screen)
Convergence Specification
White Balance Adjustment Specification
(1) 9300K
x = 0.283 ± 0.008
y = 0.298 ± 0.008
(2) 5000K
x = 0.345 ± 0.008
y = 0.358 ± 0.008
Vertical and Horizontal Position and Size
Specification
Focus adjustment
Adjust the focus volume 1 and 2 for the optimum focus.
Standard: HMC, VMC ± 0.1 mm (In the center of screen)
XBV
XCV
YBH
YCH
TLV
TLH
Purity Mg
6-pole Mg
4-pole Mg
2-pole Mg
<6 Pole Magnet>
Tab B
Tab A
Fig. 4
Fig. 3
Fig. 5
XBV
XCV
B
R
B
R
R
B
B
H. TILT 
YBH
TLV
R B
YCH
B
R
R
B
R
B
Fig. 1
Fig. 2
FBT
Focus volume 1 (V)
Focus volume 2 (H)
Page of 42
Display