DOWNLOAD Sony CPD-120AS Service Manual ↓ Size: 4.11 MB | Pages: 42 in PDF or view online for FREE

Model
CPD-120AS
Pages
42
Size
4.11 MB
Type
PDF
Document
Service Manual
Brand
Device
Monitor
File
cpd-120as.pdf
Date

Sony CPD-120AS Service Manual ▷ View online

CPD-120AS
– 13 –
3
When one side of the rubber cap is
separated from the anode button, the
anode-cap can be removed by turning
up the rubber cap and pulling up it in the
direction of the arrow 
c
.
• HOW  TO  HANDLE  AN  ANODE-CAP
1
Don’t hurt the surface of anode-caps with shartp shaped material!
2
Don’t press the rubber hardly not to hurt inside of anode-caps!
A material fitting called as shatter-hook terminal is built in the
rubber.
3
Don’t turn the foot of rubber over hardly!
The shatter-hook terminal will stick out or hurt the rubber.
• REMOVAL  OF  ANODE-CAP
NOTE: Short circuit the anode of the picture tube and the anode cap to the metal chassis, CRT shield or carbon painted on the CRT, after
removing the anode.
• REMOVING  PROCEDURES
1
Turn up one side of the rubber cap in
the direction indicated by the arrow 
a
.
2
Using a thumb pull up the rubber cap
firmly in the direction indicated by the
arrow 
b
.
2-5. PICTURE  TUBE  REMOVAL
     A block
2
     Anode cap
1
     Two screws
     (+BVTP 4 x 16)
3
     Stand assy
4
     Neck assy
5
     Deflection yoke
6
     Picture tube
8
     Four screws
     (Tapping screw 5)
7
     Demagnetization coil
9
     Tension spring
10
     Two degaussing coil holders
11
     Two degaussing coil holders
12
Cushion
a
b
c
Anode Button
CPD-120AS
– 14 –
SECTION  3
SAFETY  RELATED  ADJUSTMENT
Part Replaced (
[
)
RV501
HV ADJ
When replacing or repairing the shown below table, the fol-
lowing operational checks must be performed as a safety
precaution against X-rays emissions from the unit.
Beam Current Protector Check
Using an external DC Power Supply, applying voltage of
7.00 ± 0.05 V between !] pin of FBT (T501) and GND,
and confirm that the vlotage of both ends C519 is with in
the Voltage range shown below.
• Standard voltage : Less than 3.26 V DC
Check Condition
• Input voltage : 120.0 ± 20 V AC
• Input signal
: Dot at 64.0 kHz
(VESA 1280 
×
 1024)
• Beam control : CONT : 100 %, BRT : 40 %
B+ Voltage Check
Standard voltage : 149.0
V DC
Check Condition
• Input voltage : 120.0 ± 2.0 V AC
Note : Use NF power supply or make sure that
distortion factor is 3% or less.
• Input signal
: All white at 60.0 kHz
(VESA 1024 
×
 768)
• Beam control : CONT : 100 %, BRT : 40 %
HV Regulator
Circuit
HV Protector
Circuit
Beam Current
Protector Circuit
Part Replaced (
]
)
D board IC801, C509, C533,
C542, C548, C802,
C814, C815, R506,
R508, R538, R539,
R540, R541, R807,
R822, R823, R824,
RV501, T501 (FBT)
D board IC501, IC801, IC904,
D511, D515, D516,
C515, C516, C517,
C525, R532, R533,
R534, R535, R557,
R558, R996,
T501 (FBT)
• Mounted D board
D board IC901, D596, C519,
C528, C549, C904,
R542, R543, R544,
R545, R939
• Mounted D board
*
Confirm one minute later turning on the power.
HV Protector Circuit Check
Confirm that the HV protector circuit works and CRT
screen disappearing when apply the voltage as shown be-
low between Cathode of D511 on D board and GND us-
ing an external DC Power Supply.
• Standard voltage  :  35.20 ± 0.05 V DC
Check Condition
• Input voltage : 120.0 ± 2.0 V AC
• Input signal
: Dot at 64.0 kHz
(VESA 1280 
×
1024)
• Beam control : CONT : 100 %, BRT : 40 %
+ 2.0
– 3.0
CPD-120AS
– 15 –
SECTION  4
ADJUSTMENTS
Mechanical
Center
Set the
finger
Connect the communication cable of the computer to the connector located on the D board on the monitor.  Run the service software and
then follow the instruction.
IBM AT Computer
as a Jig
1-690-391-21
1
A-1500-819-A
Interface Unit
2
*The parts above (                ) are necessary for DAS adjustment.
1
3
D-sub
(9 Pin [female])
mini Din
(8Pin)
4 Pin
3-702-691-01
Connector Attachment
3
To BUS CONNECTOR
4 Pin
4 Pin
Convergence Rough Adjustment
Set DY four-pole magnet to mechanical center
before adjustment.
This should be prime mode.
Landing Rough Adjustment
1.
Enter the full white signal.
2.
Adjust the contrast to the maximum.
3.
Make the screen monogreen.
4.
Reverse the DY, and adjust coarsely the purity magnet so that
a green raster positions in the center of screen.
5.
Moving the DY forward, adjust so that an entire screen be-
comes monogreen.
6.
Adjust the tilt of DY, and fix lightly with a clamp.
Landing Fine Adjustment
1.
Place the set in the Helmholtz coil.
2.
Enter a green signal only.
3.
Degauss the entire screen with hand-degausser.
4.
Attach a wobbling coil to the specified position of CRT neck.
5.
Attach a landing adjuster sensor on the CRT.
6.
Using a landing checker, adjust the DY position, purity, tilt of
DY.
7.
Clamp the DY screw.
Clamping torque: 19 ± 1kgcm (1.9 ± 0.1 N.m)
Convergence Rough Adjustment
1.
Enter the white crosshatch signal.
2.
Adjusut roughly the horizontal and vertical
convergence at four-pole magnet.
3.
Adjusut roughly HMC and VMC at six-pole
magnet.
*
*
1)
Receive R.B. cross-hatch.
2)
Adjust H.STAT nad V.STAT at four-pole magnet.
<4 Pole Magnet>
4
4
1
2
4
4
1
2
B
R
1
2
R
B
B
R
1 2
+
R
B
1
2
B
R
R
B
1 2
+
NECK Assy
6PoleMg
P.S Mg
XBV
DY
CRT
4Pole Mg
CPD-120AS
– 16 –
3)
Receive White cross-hatch.
4)
Adjust HMC and VMC at six-pole magnet.
<6 Pole Magnet>
<Zero Position NECK Ass'y>
6
6
6
6
1
2
1
2
G
G
5)
Receive R.B. cross-hatch.
6)
Repeat the above procedure so that R.G.B. will on X,Y axis.
7)
Adjust H.TILT by swinging the DY neck right and left.
8)
Adjust XCV with XCV core.
1 XCV movement
B
R
10) Adjust Y.CLOTH with YCH VR.
YCH movement
B
R
11) Paint lock the four-pole and six-pole Mg.
<VR Adjustment on DY>
TLV
XCV
YCH
9)
Adjust V.TILT with TLV VR.
TLV movement
R
B
R
B
Convergence Specification
Vertical and Horizontal Position and Size
Specification
White Balance Adjustment Specification
(1) 9300K
x = 0.283 ± 0.005
y = 0.298 ± 0.005
(2) 6500K
x = 0.313 ± 0.005
y = 0.329 ± 0.005
(3) 5000K
x = 0.345 ± 0.005
y = 0.358 ± 0.005
Focus adjusutment
Adjusutment focus (V) and focus (H) for optimum focus.
B
A
0.30 mm
A
0.35 mm
B
All mode
MODE
Purity
4-Pole Mg
6-Pole Mg
A
270 mm
B
MODE All mode
202 mm
a     2.5 mm
b     2.5 mm
a
B
A
b
FBT
Focus (V)
A board
Focus (H)
Page of 42
Display

Click on the first or last page to see other CPD-120AS service manuals if exist.