CPD-110GS/110EST
3
When one side of the rubber cap is
separated from the anode button, the
anode-cap can be removed by turning
up the rubber cap and pulling up it in
the direction of the arrow 
c
.
• HOW  TO  HANDLE  AN  ANODE-CAP
1
Don’t hurt the surface of anode-caps with shartp shaped material!
2
Don’t press the rubber hardly not to hurt inside of anode-caps!
A material fitting called as shatter-hook terminal is built in the
rubber.
3
Don’t turn the foot of rubber over hardly!
The shatter-hook terminal will stick out or hurt the rubber.
a
b
Anode Button
c
• REMOVAL  OF  ANODE-CAP
NOTE: Short circuit the anode of the picture tube and the anode cap to the metal chassis, CRT shield or carbon painted on the CRT,
after removing the anode.
• REMOVING  PROCEDURES
1
Turn up one side of the rubber cap in
the direction indicated by the arrow 
a
.
2
Using a thumb pull up the rubber cap
firmly in the direction indicated by the
arrow 
b
.
2-4. PICTURE TUBE  REMOVAL
2-2
     
Demagnetic coil
12
13
     
Tension spring
2
  
 
  
A board
GND
GND
CN506
GND
GND
CN308
CN307
Two 
degaussing
coil holders
14
CN501
CN603
Two screws
(+BVTP 4 x 16)
5
     
Stand assy
4
3 Claw
Bottom cover
(D board)
7
6 Claw
Cushion
Two degaussing
coil holders
15
1
  
 
  
Anode cap
     
Picture tube
11
     
Deflection yoke
9
     
Neck assy
8
     
Four screws
(Tapping screw 5)
10
Connector
(2pin)
CPD-110GS/110EST
2-5. HARNESS LOCATION
2-3
CN901 CN902
CN504
CN603
CN605
CN301
CN310
CN505
CN506
CN501
FBT
Picture tube
Demagnetic coil
D board
A board
CN302
CN305
CN303
CN309
CN304
CN307
CN306
CN308
CPD-110GS/110EST
SECTION  3
SAFETY  RELATED  ADJUSTMENT
Part Replaced (
[
)
RV501
HV ADJ
When replacing or repairing the shown below table, the
following operational checks must be performed as a
safety precaution against X-rays emissions from the unit.
HV Protector Circuit Check
Confirm that the voltage between cathode of D521 on D
board and GND is more than 28.5 V DC and Using ex-
ternal DC Power Supply, apply the voltage shown below
between cathode of D521 and GND, and confirm that
the HV HOLD DOWN circuite works. (TV Rester dis-
appears)
Standard voltage  :  Less than 34 V DC
Check Condition
• Input voltage : 100 – 120 V AC
• Input signal
: White Cross hatch at Max fH
• Beam control : CONT : 255, BRT : 80
Beam Current Protector Check
Connect a variable resistor (250 k
 or more) and an am-
meter in series between FBT pin 1 on D board and
GND. Decrease gradually the resistance of the variable
resistor from maximum to minimum, and confirm that
the Beam Current Protector Circuite works (TV Rester
disappears). The current must be within the range shown
below.
• Standard current  :  Less than 1.50 mA
Check Condition
• Input voltage : 100 – 120 V AC
• Input signal
: White Cross hatch at Max fH
• Beam control : CONT : 255, BRT : 80
B+ Voltage Check
Standard voltage : 152 
±
 5.0 V DC
Check Condition
• Input voltage : 100 – 120 V AC
Note : Use NF power supply or make sure that
distortion factor is 3% or less.
• Input signal
: White Cross hatch at 64.0 kHz
• Beam control : CONT : 255, BRT : 80
HV Regulator
Circuit Check
HV Hold-down
Circuit Check
Beam Current
Protector Circuit
Check
*
Confirm one minute later turning on the power.
3-1
Part Replaced (
]
)
D board IC502, IC503, C501,
C535, C553, C597,
C598, R592, R593,
R596, RV501,
T501 (FBT)
D board IC501, D521, C585,
C599, R598, R599,
R5C7, T501 (FBT)
D board Q533, D592, C590,
C591, C598, R5A5,
R5C0, R5C3, L502,
T501 (FBT)
CPD-110GS/110EST
SECTION  4
ADJUSTMENTS
Landing Fine Adjustment
< Measurement condition >
Magnetic field : BH=0, BV=45
µ
T
CRT size : 270 
× 
202
Measurement point : 240 
× 
180
Temperature : 25ºC (after aging for 12 hours)
< Adjustment target>
1) The value shall be within the following spacification after
0.5 hours of aging in the product condition, all white and
with luminance 100cd/m^.
-2
-1
1
-1
0
0
1
0
-1
Connect the communication cable of the computer to the connector located on the D board on the monitor.  Run the service software
and then follow the instruction.
IBM AT Computer
as a Jig
1-690-391-21
1
A-1500-819-A
Interface Unit
2
D-sub
(9 Pin [female])
mini Din
(8Pin)
4 Pin
3-702-691-01
Connector Attachment
3
To BUS CONNECTOR
4 Pin
4 Pin
1
3
*The parts above (       ~       ) are necessary for DAS adjustment.
2) The value shall be within the following spacification after
3 hours of aging in product condition, 1/2
Σ
 1K (not in-
cluding dark current).
0
0
0
0
0
0
0
0
0
Tolerance +/- 7.
1.
Put the set inside the Helmholtz coil.
2.
Input the single green signal.
3.
Demagnetize the CRT surface with the hand degausser.
4.
Attach the wobbling coil to the designated part of the CRT
neck.
5.
Attach the sensor of the landing adjustment unit on the CRT
surface.
6.
Adjust the DY position and purity, and the DY tilt.
7.
Fasten DY with screw.
Note: Torque 22 
±
2kgcm (2.2 
±
 0.2Nm)
NECK Assy
6Pole Mg
P.S Mg
XBV
DY
CRT
4Pole Mg
Convergence Adjustment
Set DY four-pole magnet at mechanical center
before adjustment.
This should be prime mode.
*
*
Correcting XBV
In case
R
Space between two tabs
shall be less than 10mm
or 15 
°
.
B
B
R
Open 4 pole magnet of DY, Be careful don't not to change H-
STAT.
In this case
1) Open 4 pole magnet of DY. Shall not change HSTAT.
2) Re-adjust V-STAT with 4 pole magnet of neck ass'y.
Don't not perform the XBV correction excessively unless other-
wise necessary.
4-1
Page of 39