DOWNLOAD Sony DVP-NS715P Service Manual ↓ Size: 17.81 MB | Pages: 94 in PDF or view online for FREE

Model
DVP-NS715P
Pages
94
Size
17.81 MB
Type
PDF
Document
Service Manual
Brand
Device
DVD
File
dvp-ns715p.pdf
Date

Sony DVP-NS715P Service Manual ▷ View online

6-10
EEPROM DATA 3
-– DL -–
CD LCD
SL
L0
L1
Analog FRSW
xx xx
xx
xx
xx
PLL Dac Gain
xx xx
xx
xx
xx
Mirror Time
xx xx
xx
xx
xx
_  THR A&L
xx xx
xx/xx xx
xx
UP
: PREV Data
DOWN : First Data
CLEAR : Default Set
page.3/3
On this screen, current servo adjusted data stored in the EEPROM
are displayed. The adjusted data are initialized by pressing the
[CLEAR]
  key,  but be careful that they are not recoverable after
initialization.
Before clearing the adjusted data, make a note of the set data. This
screen will also appear if 
[0]
 All is selected in the Drive Auto
Adjustment. In this case, default setting cannot be made.
Data of “THR A & L” on page 3/3 can not be changed if default
set is done.
6-6.
MECHA  AGING
### Mecha Aging ###
Press OPEN key
Abort: STOP key
On the Test Mode Menu screen, selecting 
[3]
 executes the aging
of mechanism. First, open the tray and load a disc. Press
the
H
key, and the aging will start. During aging, the repeat cycle
is displayed. Aging can be aborted at any time by pressing
the
x
key. After the operation has stopped, unload the disc and
press again the
x
key or the 
[     RETURN]
 key to return to the
Test Mode Menu.
6-7.
EMERGENCY  HISTORY
### EMG. History ###
Laser Hours
CD
xxhxxm
DVD
xxhxxm
 1. 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00
 2. 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00
Select: 1-9
Scroll: UP/DOWN
(1: Last EMG.)
Exit: RETURN
On the Test Mode Menu screen, selecting 
[4]
 displays the infor-
mation such as servo emergency history. The history information
from last 1 up to 10 can be scrolled with  ↑ key or ↓ key. Also,
specific information can be displayed by directly entering that
number with ten keys.
The upper two lines display the laser ON total hours. Data below
minutes are omitted.
Clearing History Information
Clearing laser hours
Press 
[DISPLAY]
 and 
[CLEAR]
 keys in this order.
Both CD and DVD data are cleared.
Clearing emergency history
Press 
[TOP MENU]
 and 
[CLEAR]
 keys in this order.
Initializing set up data
Press 
[MENU]
 and 
[CLEAR]
 keys in this order.
The data have been initialized when “Set Up Initialized” mes-
sage is displayed. The EMG. History screen will be restored
soon.
O
6-11
6-10. IF  CON  SELF  DIAGNOSTIC  FUNCTION
1. IF-92  BOARD  (IF  CON)  TEST  MODE
The front board test mode is the IF CON self diagnostic mode.
The IF CON can diagnose the functions of the front panel boards
that the IF CON controls. Normally, the IF CON makes a serial
communication with the SYSTEM CONTROL and operates fol-
lowing the commands from the SYSTEM CONTROL, but in the
Test mode, the IF CON operates independently from the SYS-
TEM CONTROL.
In the Test mode, the following functions can be checked.
1. Button function
2. Remote commander receiving function
3. SYSTEM CONTROL-IF CON serial communication
4. Click shuttle function
5. Fluorescent display tube lighting check
Grid check
Anode check
6. LED control function
In the Test mode, the set operates same as usual, except voltage
monitoring, communication monitoring, display of fluorescent
display tube, and LED control.
1. The routine that monitors +3.3 V (P-CONT) of MB-103 board
is not provided.
2. The monitoring timer for serial communication with the SYS-
TEM CONTROL is not provided. The set is not placed in the
Standby mode, even if the communication with SYSTEM
CONTROL is normal.
3. Display of fluorescent display tube (normally, display is made
following the commands from SYSTEM CONTROL)
4. LED control (normally, control is made following the com-
mands from SYSTEM CONTROL)
2. OPERATION  OF  SELF  CHECK  MODE
The Self Check mode is the function to conduct the basic test to
the FL display and DVD panel section.
2-1. Self Check Mode Transition Processing
At the AC Power ON after IF CON (IC404) was reset, the input to
10pin (SELF CHECK) is judged and if “Low” is entered, the main
unit transits to the Self Check mode. In this port input judgment,
the result of 3-time attempts must be same (assuming that the MB-
103 and AV-63 boards are not connected). While pressing the
x
key
on the main unit with the IF CON in STANDBY mode, enter
[      RETURN]
 
→ 
[DISPLAY]
 (or 
[SET UP]
) on the remote com-
mander, and the unit transits to the Self Check Mode. The Self
Check mode terminates when the IF CON transits to the STANDBY
mode.
6-8.
VERSION  INFORMATION
### Version Infomation ###
IF con.
Ver.x.xxx(xxxx)
Group
xx
SYScon.
Ver.x.xxx(xxxx)
Model
xx
Region
0x
 Servo DSP Ver: x.xxx
 AVD ucode Ver: xxxxxxxx
 OPT TYPE : x LASER
Exit : RETURN
The ROM version, region code, OPT type, etc. are displayed if
[5]
 is selected in the Test Mode Menu.
The parenthesized hexadecimal number in the version number field
indicates the checksum value of the ROM.
Note : After down loading ROM data, sometimes it happens that
checksum is not the same as that of ROM data which has
been down loaded. In such a case, go back to the menu
and select “0. Syscon Diagnosis”, then select “1. All” in
“2. Version”. If the result of this operation does not give
an agreement, it must be either Down Load error or ROM
error.
6-9.
VIDEO  LEVEL  ADJUSTMENT
On the Test Mode Menu screen, selecting 
[6]
 displays color bars
for video level adjustment. During display of color bars, OSD dis-
appears but the menu screen will be restored if pressing any key.
O
6-12
2-2. Operation of Auto Self Check
When the Self Check mode becomes active at the AC Power ON
or by key input, the test display of the following steps (1) to (4) is
repeated.
(1) FLD and LED all ON (for 5 seconds)
(2) MODEL display (for 2 seconds)
(3) Version display (for 2 seconds)
(4) ROM creation date display (for 2 seconds)
VCD
PROGRESSIVE MULTI
MP 3
SHUFFLE
REPEAT
1
;
Digital
PGM
GROUP TITLE TRACK CHAP INDEX ANGLE NTSC HOUR
MIN
SEC
A-
B
DVD
CD
VCD
PROGRESSIVE
MULTI
MP 3
SHUFFLE
REPEAT
1
;
Digital
PGM
GROUP TITLE TRACK
CHAP INDEX ANGLE NTSC HOUR
MIN
SEC
A-
B
DVD
CD
GROUP TITLE TRACK CHAP INDEX ANGLE NTSC HOUR
MIN
SEC
VCD
PROGRESSIVE MULTI
MP 3
SHUFFLE
REPEAT
1
;
Digital
PGM A-
B
DVD
CD
VCD
PROGRESSIVE MULTI
MP 3
SHUFFLE
REPEAT
1
;
Digital
PGM A-
B
DVD
CD
GROUP TITLE TRACK CHAP INDEX ANGLE NTSC HOUR
MIN
SEC
6-13
2-3. Each Self Check Function
Each Self Check function tests the FLD display, LED display, and
key input.
2-3-1. FLD and LED All ON
2-3-1-1. Transition Keys in Self Check Mode
 x
key and
A
key on the main unit
•  
← key on the main unit and the remote commander
2-3-1-2. Operation and Display
In this mode, all LEDs except STANDBY LED and all segments
of FLD turn ON.
Example of FLD all ON
2-3-2. Main Unit Key Name Display and Key Code Display
2-3-2-1. Transition Keys in Self Check Mode
• Keys on main unit except keys transited in self check
2-3-2-2. Operation and Display
When a key on the main unit is pressed in the Self Check mode,
the name of that key is displayed on the FLD. Also, the key name
display and the key code display can be switched with the
[DISPLAY]
 key on the remote commander. “NOTHING” is dis-
played when nothing is entered. Also, VIDEO CD, DVD, and CD
segments turn on when a communication error occurred.
FLD display (at input of
H
key on the main unit)
Input
IC404: Pin No. (Signal)
Voltage [V]
Pin ed (CURSOR)
Pin ef (O/C)
Pin eg (PLAY)
Pin eh (DISPLAY) Pin ej (POWER)
0 – 0.2
ENTER
OPNE/CLOSE
PLAY
STOP
POWER
0.6 – 0.82
DOWN
PREVIOUS
DISPLAY
TVS
1.16 – 1.47
LEFT
PAUSE
MENU
PVEQ
1.8 – 2.12
UP
NEXT
RETURN
2.48 – 2.7
RIGHT
TOP MENU
3.3
VCD
PROGRESSIVE MULTI
MP 3
SHUFFLE
REPEAT
1
;
Digital
PGM
GROUP TITLE TRACK CHAP INDEX ANGLE NTSC HOUR
MIN
SEC
A-
B
DVD
CD
VCD
PROGRESSIVE
MP 3
MULTI
SHUFFLE
REPEAT
1
;
Digital
PGM
GROUP TITLE TRACK CHAP INDEX ANGLE NTSC HOUR
MIN
SEC
A-
B
DVD
CD
Page of 94
Display