DOWNLOAD Sony DVP-NS425P Service Manual ↓ Size: 21.21 MB | Pages: 71 in PDF or view online for FREE

Model
DVP-NS425P
Pages
71
Size
21.21 MB
Type
PDF
Document
Service Manual
Brand
Device
DVD
File
dvp-ns425p.pdf
Date

Sony DVP-NS425P Service Manual ▷ View online

6-3
(21)
Push “4. Save to EEPROM”.
(22)
Confirm the same values are displayed. If it is not the
same, return to step 15.
MIRR time adjustment Menu
1. CD MIRR time check:  YY  YY
2. DVD MIRR time check:  XX  XX
3. Threshold:
4. Save to EEPROM:
5. Default set MIRR time:
[Open] Tray open [close] tray close
[0] Return to previous menu
(23)
Push “3. Threshold” to confirm the Threshold number. If it
is 70 ~ 7A, proceed to the next step. Otherwise, return to
step 7. In case of the Threshold number does not become
70 ~ 7A after retry 3 times, exchange the BU.
(24)
Push “Open / Close” key to eject tray.
(25)
Remove Test Disc YEDS-18 from tray.
(26)
Push “Open / Close” key to close tray.
(27)
Press “0” to return to the Remocon Diagnosis Menu and
press power button to switch OFF the DVD player.
6-5.
EXECUTING IOP MEASUREMENT
In order to execute mirror time adjustment, the following standard
procedures must be followed.
(1)
In standby mode, press 
[TOP MENU]
[CLEAR]
,
[POWER]
 to enter Remocon Diagnosis Mode.
Remocon Diagnosis Menu
0. External Chip Check
1. Servo Parameter Check
2. Drive Manual Operation
3. Emergency History Check
4. Version information
5. Video Level Adjustment
Model
: DPX-1790_UC2
IF-con  Ver
: 1.000 (5B84)
Syscon  Ver : 1.81
(2)
Select “2. Drive Manual Operation” by pressing the 2
key on the remote commander. The screen will appear as
below.
Drive Manual Operation
1. Servo Control
2. Track/Layer Jump
3. Manual Adjustment
4. Tray Aging Mode
5. MIRR time adjust
0. Return to top Menu
(3)
Select “3. Manual Adjustment” by pressing the 3 key on
the remote commander. The screen will appear as below.
Manual Adjust
1. Track Balance Adjust:
2. Track Gain Adjust:
3. Focus Balance Adjust:
4. Focus Gain Adjust:
5. Eg boost Adjust:
6. Iop:
7. TRV. Level:
8. S curve(FE) Level:
9. RFL(PI) Level:
0. MIRR Time:
?  ?  Change Value
[RETURN] Return to previous menu
(4)
Select Iop by pressing 6 key on the remote commander.
(5)
Wait until a hexadecimal number appear.
Manual Adjust
1. Track Balance Adjust:
2. Track Gain Adjust:
3. Focus Balance Adjust:
4. Focus Gain Adjust:
5. Eq Boost Adjust:
6. Iop. ED 9E:
7. TRV. Level:
8. S curve(FE) Level:
9. RFL(PI) Level:
0. MIRR Time:
Change Value
[0] Return to previous menu
(6)
Convert each data from hexadecimal to decimal using
conversion table.
(7)
Substract between these two values.
(8)
If the remainder is smaller than 93 (decimal), then it is
OK. However if the value is higher than 93, then the BU
is defective and need to be change.
(9)
Press [RETURN] to return back to previous menu.
(10)
Press 0 to return to Top Menu and power OFF the DVD
Player.
7-1
7-1. POWER  SUPPLY  CHECK
Mode
E-E
Instrument
Digital voltmeter
EVER +5.0 V Check
Test point
CN201 pin qa
Specification
5.0 ± 0.3 Vdc
SW +3.5 V Check
Test point
CN201 pin  0
Specification
3.4 ± 0.2 Vdc
SW+5 V Check
Test point
CN201 pin qs
Specification
5.0 ± 0.3 Vdc
SW + 8 V Check
Test point
CN201 pin 5, 6
Specification
8.0 ± 0.5 Vdc
EVER + 8 V Check
Test point
CN201 pin qd
Specification
8.0 ± 0.5 Vdc
EVER –15.5 V Check
Test point
CN201 pin  2
Specification
–15.5 ± 1.0 Vdc
Checking method:
1) Confirm that each voltage satisfies the specification.
Note
Because the heatsink installed on the power supply board is a
part of the primary side, never touch it to avoid electrical shock.
SECTION  7
ELECTRICAL ADJUSTMENT
DVP-NS425P
This section describes procedures and instructions necessary for
adjusting electrical circuits in this set.
Instruments required:
1) Digital voltmeter
8-1
DVP-NS425P
SECTION  8
REPAIR  PARTS  LIST
The components identified by
mark 
  or dotted line with mark
  are critical for safety.
Replace only with part number speci-
fied.
Les composants identifiés par une
marque 
  sont critiquens pour la
sécurité.
Ne les remplacer que par une pièce
portant le numéro spécifié.
NOTE:
• -XX and -X mean standardized parts, so they
may have some difference from the original one.
• Items marked “*” are not stocked since they are
seldom required for routine service. Some de-
lay should be anticipated when ordering these
items.
• The mechanical parts with no reference number
in the exploded views are not supplied.
• Color Indication of Appearance Parts Example:
KNOB, BALANCE (WHITE) . . . (RED)
R
R
Parts Color Cabinet's Color
8-1. EXPLODED VIEWS
8-1-1. MAIN SECTION
ns : not supplied
a
a
e
c
d
e
l
k
k
o
f
g
h
f
g
o
n
5
7
6
9
9
8
4
qk
9
9
2
qa
w;
1
qf
qf
qg
qh
q;
m
qs
qs
qd
qj
m
d
h
l
j
j
n
Note :
The components identified
by mark 
 or dotted line
with mark 
 are critical for
safety.
Replace only with par t
number specified.
Note :
Les composants identifiés par
une marque 
 sont critiques
pour la sécurité.
Ne les remplacer que par une
pièce portant le numéro spécifié.
1
A-6071-274-A AF-99SM (U) COMPL
2
A-6071-276-A MB-113SM (UZ) COMPL
4
1-468-778-11 POWER BLOCK
5
X-3953-652-1 PANEL ASSY, FRONT
6
3-066-225-11 SONY BADGE (5-A)
7
3-073-777-61 EMBLEM, DVD
8
3-081-651-02 COVER, TRAY (P)
9
3-970-608-01 SUMITITE (B3), +BV
10
3-073-182-02 BUSHING, CODE
11
1-823-597-11 CORD, POWER
1 2
3-070-883-12 SCREW, TAPPING
1 3
3-080-912-11 CASE UPPER
1 3
3-080-912-41 CASE, UPPER
Ref. No.
Part No.
Description
Remark
Ref. No.
Part No.
Description
Remark
1 4
3-970-608-51 SUMITITE (B3), +BV
1 5
1-477-724-11 REMOTE COMMANDER (RMT-D153A)
1 6
3-073-096-01 LID, BATTERY CASE
1 7
3-710-901-11 SCREW, TAPPING
1 8
4-951-620-01 SUMITITE (B3), TBV
1-827-502-11 FFC FFS-11
4-951-620-01 SCREW (2.6x8), +BVTP
8-2
8-1-2. MECHANISM  DECK  ASSEMBLY
ns : not supplied
Ref. No.
Part No.
Description
Remark
101
A-6071-197-A LOADING ASSY (J)
102
3-085-021-01 INSULATOR
103
3-067-344-01 INSULATOR SCREW
104
A-6071-561-A KHM300AAA SERVICE ASSY
105
1-763-967-11 MOTOR, DC
106
3-085-015-01 DRIVING GEAR
107
3-085-016-01 PULLEY GEAR
108
3-085-019-01 BELT
109
4-974-711-11 SCREW (2x5)(P TYIGHT), (+)PTTWH
110
3-085-013-01 FC  COVER
Note :
The components identified
by mark 
 or dotted line
with mark 
 are critical for
safety.
Replace only with par t
number specified.
Note :
Les composants identifiés par
une marque 
 sont critiques
pour la sécurité.
Ne les remplacer que par une
pièce portant le numéro spécifié.
102
102
101
105
103
103
104
103
102
not supplied
110
107
106
109
108
Page of 71