DOWNLOAD Sony DVP-NS300 Service Manual ↓ Size: 17.28 MB | Pages: 112 in PDF or view online for FREE

Model
DVP-NS300
Pages
112
Size
17.28 MB
Type
PDF
Document
Service Manual
Brand
Device
DVD
File
dvp-ns300.pdf
Date

Sony DVP-NS300 Service Manual ▷ View online

6-11
6-8.
VERSION  INFORMATION
## Version Information ##
IF con.
Ver : x. xxx (xxxx)
Group    00
SYScon.
Ver : x. xxx (xxxx)
Model    xx
Region   0x
Servo DSP.  Ver : 1. xxxx
OPT Type : x LASER
Exit: RETURN
_
The ROM version, region code, OPT type, etc. are displayed if
[5]
 is selected in the Test Mode Menu.
The parenthesized hexadecimal number in the version number field
indicates the checksum value of the ROM.
Note : After down loading ROM data, sometimes it happens that
checksum is not the same as that of ROM data which has
been down loaded. In such a case, go back to the menu
and select “0. Syscon Diagnosis”, then select “1. All” in
“2. Version”. If the result of this operation does not give
an agreement, it must be either Down Load error or ROM
error.
6-9.
VIDEO  LEVEL  ADJUSTMENT
On the Test Mode Menu screen, selecting 
[6]
 displays color bars
for video level adjustment. During display of color bars, OSD dis-
appears but the menu screen will be restored if pressing any key.
Measurement point
: LINE OUT VIDEO
(75 
 terminating resistance)
Measuring instrument : Oscilloscope
Adjustment device
: RV501 on MB-98 board
Specified value
: 1.0
+ 0.04
 Vp-p
– 0.02
1.0
+ 0.04
 Vp-p
– 0.02
6-10. IF  CON  SELF  DIAGNOSTIC  FUNCTION
1. IF-80  BOARD  (IF  CON)  TEST  MODE
The front board test mode is the IF CON self diagnostic mode.
The IF CON can diagnose the functions of the front panel boards
that the IF CON controls. Normally, the IF CON makes a serial
communication with the SYSTEM CONTROL and operates fol-
lowing the commands from the SYSTEM CONTROL, but in the
Test mode, the IF CON operates independently from the SYS-
TEM CONTROL.
In the Test mode, the following functions can be checked.
1. Button function
2. Remote commander receiving function
3. SYSTEM CONTROL-IF CON serial communication
4. Click shuttle function
5. Fluorescent display tube lighting check
Grid check
Anode check
6. LED control function
In the Test mode, the set operates same as usual, except voltage
monitoring, communication monitoring, display of fluorescent
display tube, and LED control.
1. The routine that monitors +3.3 V (P-CONT) of MB-98 board
is not provided.
2. The monitoring timer for serial communication with the SYS-
TEM CONTROL is not provided. The set is not placed in the
Standby mode, even if the communication with SYSTEM
CONTROL is normal.
3. Display of fluorescent display tube (normally, display is made
following the commands from SYSTEM CONTROL)
4. LED control (normally, control is made following the com-
mands from SYSTEM CONTROL)
2. OPERATION  OF  SELF  CHECK  MODE
The Self Check mode is the function to conduct the basic test to
the FL display and DVD panel section.
2-1. Self Check Mode Transition Processing
At the AC Power ON after IF CON (IC404) was reset, the input to
10pin (SELF CHECK) is judged and if “Low” is entered, the main
unit transits to the Self Check mode. In this port input judgment,
the result of 3-time attempts must be same (assuming that the MB-
98  and AV-56 boards are not connected). While pressing the 
[STOP]
key on the main unit with the IF CON in STANDBY mode, enter
[RETURN]
 
 
[DISPLAY]
 (or 
[SET UP]
) on the remote commander,
and the unit transits to the Self Check Mode. The Self Check mode
terminates when the IF CON transits to the STANDBY mode.
6-12
S
 
H
 
U
 
F
 
F
 
L
 
E
Digital
MPEG
DTS
DISC
PBC
ANGLE
REPEAT 1
PGM
A- B
NTSC
TITLE
TRACK
CHAP
INDEX
HOUR
MIN
SEC
VIDEO CD
D V D
C D
S
 
H
 
U
 
F
 
F
 
L
 
E
Digital
MPEG
DTS
DISC
PBC
ANGLE
REPEAT 1
PGM
A- B
NTSC
TITLE
TRACK
CHAP
INDEX
HOUR
MIN
SEC
VIDEO CD
D V D
C D
S
 
H
 
U
 
F
 
F
 
L
 
E
Digital
MPEG
DTS
DISC
PBC
ANGLE
REPEAT 1
PGM
A- B
NTSC
TITLE
TRACK
CHAP
INDEX
HOUR
MIN
SEC
VIDEO CD
D V D
C D
S
 
H
 
U
 
F
 
F
 
L
 
E
Digital
MPEG
DTS
DISC
PBC
ANGLE
REPEAT 1
PGM
A- B
NTSC
TITLE
TRACK
CHAP
INDEX
HOUR
MIN
SEC
VIDEO CD
D V D
C D
S
 
H
 
U
 
F
 
F
 
L
 
E
2-2. Operation of Auto Self Check
When the Self Check mode becomes active at the AC Power ON
or by key input, the test display of the following steps (1) to (4) is
repeated.
(1) FLD and LED all ON (for 5 seconds)
(2) MODEL display (for 2 seconds)
(3) Version display (for 2 seconds)
(4) ROM creation date display (for 2 seconds)
6-13
2-3. Each Self Check Function
Each Self Check function tests the FLD display, LED display, and
key input.
2-3-1. FLD and LED All ON
2-3-1-1. Transition Keys in Self Check Mode
[STOP]
 key and 
[OPEN/CLOSE]
 key on the main unit
[LEFT]
 key on the main unit and the remote commander
2-3-1-2. Operation and Display
In this mode, all LEDs except STANDBY LED and all segments
of FLD turn ON.
Example of FLD all ON
S
 
H
 
U
 
F
 
F
 
L
 
E
Digital
MPEG
DTS
DISC
PBC
ANGLE
REPEAT 1
PGM
A- B
NTSC
TITLE
TRACK
CHAP
INDEX
HOUR
MIN
SEC
VIDEO CD
D V D
C D
S
 
H
 
U
 
F
 
F
 
L
 
E
2-3-2. Main Unit Key Name Display and Key Code Display
2-3-2-1. Transition Keys in Self Check Mode
• Keys on main unit except keys transited in self check
2-3-2-2. Operation and Display
When a key on the main unit is pressed in the Self Check mode,
the name of that key is displayed on the FLD. Also, the key name
display and the key code display can be switched with the 
[DIS-
PLAY]
 key on the remote commander. “NOTHING” is displayed
when nothing is entered. Also, VIDEO CD, DVD, and CD seg-
ments turn on when a communication error occurred.
FLD display (at input of 
[PLAY]
 key on the main unit)
S
 
H
 
U
 
F
 
F
 
L
 
E
Digital
MPEG
DTS
DISC
PBC
ANGLE
REPEAT 1
PGM
A- B
NTSC
TITLE
TRACK
CHAP
INDEX
HOUR
MIN
SEC
VIDEO CD
D V D
C D
Input
IC404: Pin No. (Signal)
Voltage [V]
Pin ed
 (BNRKEY)
Pin ef
 (O/C)
Pin eg
 (PLAY)
Pin eh
 (DISPLAY)
Pin ej
 (CURSOR)
0
SURROUND
OPEN/CLOSE
PLAY
STOP
ENTER
0.70
BNR
PAUSE
DISPLAY
DOWN
1.31
PREVIOUS
DVD MENU
LEFT
1.97
NEXT
RETURN
UP
2.59
TITLE
RIGHT
3.3
6-14
Key code display (at input of 
[PLAY]
 key, Key code: 0Ah)
S
 
H
 
U
 
F
 
F
 
L
 
E
Digital
MPEG
DTS
DISC
PBC
ANGLE
REPEAT 1
PGM
A- B
NTSC
TITLE
TRACK
CHAP
INDEX
HOUR
MIN
SEC
VIDEO CD
D V D
C D
Digital
MPEG
DTS
DISC
PBC
ANGLE
REPEAT 1
PGM
A- B
NTSC
TITLE
TRACK
CHAP
INDEX
HOUR
MIN
SEC
VIDEO CD
D V D
C D
S
 
H
 
U
 
F
 
F
 
L
 
E
Digital
MPEG
DTS
DISC
PBC
ANGLE
REPEAT 1
PGM
A- B
NTSC
TITLE
TRACK
CHAP
INDEX
HOUR
MIN
SEC
VIDEO CD
D V D
C D
At input of faulty voltage
When two keys are pressed
2-3-3. Remote Commander Key Name Display and Key
Code Display
2-3-3-1. Transition Keys in Self Check Mode
• Remote commander keys except keys transited in self check
2-3-3-2. Operation and Display
When a key on the remote commander is pressed in the Self Check
mode, the name of that key is displayed on the FLD. Also, the key
name display and the key code display can be switched with the
[DISPLAY]
 key on the remote commander. “NOTHING” is dis-
played when nothing is entered. Also, VIDEO CD, DVD, and CD
segments turn on when a communication error occurred.
Remote commander key name display (at input of 
[PAUSE]
 key)
S
 
H
 
U
 
F
 
F
 
L
 
E
Digital
MPEG
DTS
DISC
PBC
ANGLE
REPEAT 1
PGM
A- B
NTSC
TITLE
TRACK
CHAP
INDEX
HOUR
MIN
SEC
VIDEO CD
D V D
C D
S
 
H
 
U
 
F
 
F
 
L
 
E
Digital
MPEG
DTS
DISC
PBC
ANGLE
REPEAT 1
PGM
A- B
NTSC
TITLE
TRACK
CHAP
INDEX
HOUR
MIN
SEC
VIDEO CD
D V D
C D
Remote commander key code display (at input of 
[PAUSE]
 key,
Key code: 39h)
Page of 112
Display

Click on the first or last page to see other DVP-NS300 service manuals if exist.