6-10
How to see Emergency History
1 : Emergency Code
2 : Don’t Care
These codes are used for verification of software designing.
3 : Historical order 1 to 9
Emergency Codes List
10: Communication to IC001 (TK-51 board) failed.
11: Each servo for focus, tracking, and spindle is unlocked.
12: Communication to EEPROM, IC201 (MB-82 board) failed.
13: Writing of hours meter data to EEPROM, IC201 (MB-82
board)  failed.
14: Communication to Servo DSP IC701 (MB-82 board) failed,
or Servo DSP is faulty.
20: Initialization of tilt servo and sled servo failed. They are not
placed in the initial position.
21: Tilt servo operation error
22: Syscon made a request to move the tilt servo to wrong posi-
tion.
23: Sled servo operation error
24: Syscon made a request to move the sled servo to wrong posi-
tion.
30: Tracking balance adjustment error
31: Tracking gain adjustment error
32: Focus balance adjustment error
33: Focus bias adjustment error
34: Focus gain adjustment error
35: Tilt servo adjustment error
36: RF equalizer adjustment error
37: RF group delay adjustment error
38: Jitter value after adaptive servo operation is too large.
40: Focus servo does not operate.
41: With a dual layer (DL) disc, focus jump failed.50: CLV
(spindle) servo does not operate.
51: Spindle does not stop.
60: With a DVD disc, Syscon made a request to seek nonexistent
address.
61: With a CD disc, Syscon made a request to seek nonexistent
address.
62: With a CD disc, Syscon made a request to seek nonexistent
track No. and index No.
63: With a DVD disc, seeking of target address failed.
64: With a CD disc, seeking of target address failed.
65: With a CD disc, seeking of target index failed.
70: With a DVD disc, physical information data could not be read.
71: With a CD disc, TOC data could not be read.
80: Disc type judgment failed.
81: As disc type judgment failed, retry was repeated.
82: As disc type judgment failed, a measurement error occurred.
83: Disc type could not be judged within the specified time.
84: Illegal command code was received from Syscon.
85: Illegal command was received from Syscon.
1.0 
±
 0.02 Vp-p
6-8.
VERSION  INFORMATION
## Version Information ##
IF con.
Ver. x. xxx (xxxx)
Group    00
SYScon.
Ver. x. xxx (xxxx)
Model    xx
Region   0x
SW1      ??
SW2      ??
Exit: RETURN
On the Test Mode Menu screen, selecting 
[5]
 displays the ROM
version and region code.
The parenthesized hexadecimal number in version field is
checksum value of ROM.
6-9.
VIDEO  LEVEL  ADJUSTMENT
On the Test Mode Menu screen, selecting 
[6]
 displays color bars
for video level adjustment. During display of color bars, OSD dis-
appears but the menu screen will be restored if pressing any key.
Measurement point
: LINE OUT VIDEO
(75 
 terminating resistance)
Measuring instrument : Oscilloscope
Adjustment device
: RV401 on MB-82 board
Specified value
: 1.0 ± 0.02 Vpp
6-10 E
3
1.
1
2
2
7-1
7-1. POWER  SUPPLY  ADJUSTMENT
1. Power Supply Check
(HS-030SH/030SU BOARD)
Mode
E-E
Instrument
Digital voltmeter
+5 V Check
Test point
CN202 pin 5
Specification
5.0 ± 0.2 Vdc
+3.3 V Check
Test point
CN202 pin 7
Specification
3.3 ± 0.2 Vdc
EVER+5 V Check
Test point
CN203 pin 2
Specification
5.0 ± 0.2 Vdc
P_CONT Check
Test point
CN203 pin 1
Specification
4V – 5 Vdc
A +12 V Check
Test point
CN202 pin 1
Specification
9.5       Vdc
–12 V Check
Test point
CN203 pin 5
Specification
–12.0 ± 1.0 Vdc
M +12 V Check
Test point
CN202 pin 2
Specification
12.0 ± 1.0 Vdc
Checking method:
1) Confirm that each voltage satisfies the specification.
SECTION  7
ELECTRICAL  ADJUSTMENTS
DVP-K880D
In making adjustment, refer to 7-3. Adjustment
Related Parts Arrangement.
Note
: During diagnostic check, the characters and color bars can
be seen only with the NTSC monitor. Therefore, for diag-
nostic check, use the monitor that supports both NTSC and
PAL modes
This section describes procedures and instructions necessary for
adjusting electrical circuits in this set.
Instruments required:
1) Color monitor TV
2) Oscilloscope 1 or 2 phenomena, band width over 100 MHz,
with delay mode
3) Frequency counter (over 8 digits)
4) Digital voltmeter
5) Standard commander (RMT-D110E/D111E)
6) DVD reference disc
HLX-501 (J-6090-071-A) (dual layer)
HLX-503 (J-6090-069-A) (single layer)
HLX-504 (J-6090-088-A) (single layer)
HLX-505 (J-6090-089-A) (dual layer)
7) SACD reference disc
HLXA-509 (J-6090-090-A)
+1.5
–0.5
7-2
7-2. ADJUSTMENT  OF  VIDEO  SYSTEM
1. Video Level Adjustment (MB-82 BOARD)
<Purpose>
This adjustment is made to satisfy the NTSC standard, and if not
adjusted correctly, the brightness will be too large or small.
Mode
Video level adjustment in test mode
Signal
Color bars
Test point
LINE OUT (VIDEO) connector
(75 
Ω 
terminated)
Instrument
Oscilloscope
Adjusting element
RV401
Specification
1.0 ± 0.02 Vp-p
Adjusting method:
1) In the test mode initial menu “6” Video Level Adjustment, set
so that color bars are generated.
2) Adjust the RV401 to attain 1.0 ± 0.02 Vp-p.
Figure 7-1
2. S-terminal Output Check (MB-82 BOARD)
<Purpose>
Check S-terminal video output.  If it is incorrect, pictures will not
be displayed correctly in spite of connection to the TV with a S-
terminal cable.
Mode
Video level adjustment in test mode
Signal
Color bars
Test point
S VIDEO OUT (S-Y) connector
(75 
Ω 
terminated)
Instrument
Oscilloscope
Specification
1.0 ± 0.1 Vp-p
Checking method:
1) In the test mode initial menu “6” Video Level Adjustment, set
so that color bars are generated.
2) Confirm that the S-Y level is 1.0 ± 0.1 Vp-p.
Figure 7-2
3. Checking Component Video Output B-Y
(MB-82 BOARD)
<Purpose>
This checks component video output B-Y.  If it is incorrect, cor-
rect colors will not be displayed when connected to, for instance,
projector.
Mode
Video level adjustment in test mode
Signal
Color bars
Test point
COMPONENT VIDEO OUT (B-Y)
connector (75 
Ω 
terminated)
Instrument
Oscilloscope
Specification
700 ± 70 mVp-p
Checking method:
1) Confirm that the B-Y level is 700 ± 70 mVp-p.
Figure 7-3
4. Checking Component Video Output R-Y
(MB-82 BOARD)
<Purpose>
This checks component video output R-Y.  If it is incorrect, cor-
rect colors will not be displayed when connected to, for instance,
projector.
Mode
Video level adjustment in test mode
Signal
Color bars
Test point
COMPONENT VIDEO OUT (R-Y)
connector (75 
Ω 
terminated)
Instrument
Oscilloscope
Specification
700 ± 70 mVp-p
Checking method:
1) Confirm that the R-Y level is 700 ± 70 mVp-p.
Figure 7-4
700 ± 70 mVp-p
1.0 ± 0.02 Vp-p
1.0 ± 0.1 Vp-p
700 ± 70 mVp-p
7-3
7-4 E
5. Checking Component Video Output Y
(MB-82 BOARD)
<Purpose>
This checks component video output Y.  If it is incorrect, correct
brightness will not be attained when connected to, for instance,
projector.
Mode
Video level adjustment in test mode
Signal
Color bars
Test point
COMPONENT VIDEO OUT (Y)
connector (75 
Ω 
terminated)
Instrument
Oscilloscope
Specification
1.0 ± 0.1 Vp-p
Checking method:
1) Confirm that the Y level is 1.0 ± 0.1 Vp-p.
Figure 7-5
6. Checking S Video Output S-C (MB-82 BOARD)
<Purpose>
This checks whether the S-C satisfies the NTSC Standard.  If it is
not correct, the colors will be too dark or light.
Mode
Video level adjustment in test mode
Signal
Color bars
Test point
CN005 pin 5
Instrument
Oscilloscope
Specification
286 ± 50 mVp-p
Connection:
Checking method:
1) Confirm that the S-C burst is 286 ± 50 mVp-p.
Figure 7-6
7-3. ADJUSTMENT  RELATED  PARTS  ARRANGEMENT
MB-82  BOARD (SIDE  A)
HS-030SH/030SU  BOARD (SIDE  A)
1.0 ± 0.1 Vp-p
286 ± 50 mVp-p
4
5
100
µ
F
75
±
1%
100k
±
1%
CN005
+
Oscilloscope
1
2
27
28
CN005
RV401
VIDEO LEVEL ADJ
1
1
7
6
CN202
CN203
Page of 113